Reliable quantification of bisphenol A and its chlorinated derivatives in human breast milk using UPLC-MS/MS method

被引:46
|
作者
Cariot, Axelle [1 ,2 ]
Dupuis, Antoine [1 ,2 ]
Albouy-Llaty, Marion [1 ,2 ]
Legube, Bernard [3 ]
Rabouan, Sylvie [1 ]
Migeot, Virginie [1 ,2 ]
机构
[1] Univ Poitiers, CNRS UMR IC2MP 7285, Sch Med & Pharm, Dept Analyt Chem Pharmaceut & Epidemiol, F-86034 Poitiers, France
[2] Univ Hosp Poitiers, F-86021 Poitiers, France
[3] Univ Poitiers, CNRS UMR IC2MP 7285, Ecole Natl Super Ingn Poitiers, F-86022 Poitiers, France
关键词
Bisphenol A; Bisphenol A chlorinated derivatives; Human breast milk; UPLC MS/MS; TANDEM MASS-SPECTROMETRY; HUMAN EXPOSURE; ENVIRONMENTAL CHEMICALS; ENDOCRINE DISRUPTORS; ISSUES; HPLC; DILUTION; SAMPLES; HEALTH; TISSUE;
D O I
10.1016/j.talanta.2012.08.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Bisphenol A is a widespread industrial chemical which over the past decade has demonstrated its toxicity as an endocrine disruptor. Chlorine present in drinking water may react with bisphenol A to form chlorinated derivatives, which have demonstrated a heightened level of estrogenic activity. In this work, we have comprehensively validated a method using on-line SPE-UPLC-MS/MS and isotope dilution quantification to measure bisphenol A and its chlorinated derivatives in human breast milk according to accepted guidelines. Deutered bisphenol A was used as internal standard. The matrix calibration curve ranged from 0.40 to 6.40 ng/mL for each of the target compounds and provided good linearity (r(2) > 0.99). This method was precise (the intra and inter-day coefficient of variation was <20% at two different concentrations (0.40 and 3.20 ng/mL) and accurate (recovery ranged from 81% to 119%). The limits of detection obtained for BPA and its chlorinated derivatives ranged from 0.01 to 0.09 ng/ml.. The limit of quantification for all the compounds validated at 0.40 ng/mL when using 500 mu L of milk was found to be suitable for the concentration existing in real samples. The analytical method developed in this study is in accordance with the requirements applicable to biomonitoring of BPA and its chlorinated derivatives in human breast milk. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:175 / 182
页数:8
相关论文
共 50 条
  • [1] Reliable quantification of bisphenol A and its chlorinated derivatives in human urine using UPLC-MS/MS method
    Venisse, N.
    Grignon, C.
    Brunet, B.
    Thevenot, S.
    Bacle, A.
    Migeot, V.
    Dupuis, A.
    TALANTA, 2014, 125 : 284 - 292
  • [2] Ultrasensitive determination of bisphenol A and its chlorinated derivatives in urine using a high-throughput UPLC-MS/MS method
    Claire Grignon
    Nicolas Venisse
    Steeve Rouillon
    Bertrand Brunet
    Astrid Bacle
    Sarah Thevenot
    Virginie Migeot
    Antoine Dupuis
    Analytical and Bioanalytical Chemistry, 2016, 408 : 2255 - 2263
  • [3] Erratum to: Ultrasensitive determination of bisphenol A and its chlorinated derivatives in urine using a high-throughput UPLC-MS/MS method
    Claire Grignon
    Nicolas Venisse
    Steeve Rouillon
    Bertrand Brunet
    Astrid Bacle
    Sarah Thevenot
    Virginie Migeot
    Antoine Dupuis
    Analytical and Bioanalytical Chemistry, 2016, 408 : 2375 - 2375
  • [4] Pharmacokinetic study of clarithromycin in human breast milk by UPLC-MS/MS
    Kul, Aykut
    Ozdemir, Murat
    Sagirli, Olcay
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 208
  • [5] Development and validation of a rapid, simple, and reliable UPLC-MS/MS method for the quantification of vancomycin in human plasma
    Vinh, Tho Do Chau Minh
    Thanh, Sil Nguyen
    Bich, Tram To
    Diem, Tien Le Thi
    Anh, Thi Huynh Huynh
    Do, Tuyen Ngoc
    PHARMACIA, 2024, 71
  • [6] Ultrasensitive determination of bisphenol A and its chlorinated derivatives in urine using a high-throughput UPLC-MS/MS method (vol 408, pg 2255, 2016)
    Grignon, Claire
    Venisse, Nicolas
    Rouillon, Steeve
    Brunet, Bertrand
    Bacle, Astrid
    Thevenot, Sarah
    Migeot, Virginie
    Dupuis, Antoine
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (09) : 2375 - 2375
  • [7] Development of a method by UPLC-MS/MS for the quantification of tizoxanide in human plasma and its pharmacokinetic application
    Marcelin-Jimenez, Gabriel
    Contreras-Zavala, Leticia
    Maggi-Castellanos, Martha
    Angeles-Moreno, Alionka P.
    Garcia-Gonzalez, Alberto
    BIOANALYSIS, 2012, 4 (08) : 909 - 917
  • [8] Development and validation of a UPLC-MS/MS method for quantification of doxofylline and its metabolites in human plasma
    Fang, Li-Na
    Mao, Ming-Qing
    Zhao, Xiao-Hua
    Yang, Ling
    Jia, Hui
    Xia, Shu-Yue
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 174 : 220 - 225
  • [9] Highly sensitive UPLC-MS/MS method for the quantification of paromomycin in human plasma
    Roseboom, Ignace C.
    Thijssen, Bas
    Rosing, Hilde
    Mbui, Jane
    Beijnen, Jos H.
    Dorlo, Thomas P. C.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 185
  • [10] Development of a robust UPLC-MS/MS method for the quantification of riluzole in human plasma and its application in pharmacokinetics
    Sun, Zhuo
    Liu, Xin
    Zuo, Wei
    Fu, Qiang
    Xu, Tingting
    Cui, Liying
    Zhang, Bo
    Peng, Ying
    FRONTIERS IN PHARMACOLOGY, 2023, 14