Improvement of part-load performance of gas turbine by adjusting compressor inlet air temperature and IGV opening

被引:0
|
作者
Wei Zhu
Xiaodong Ren
Xuesong Li
Chunwei Gu
Zhitan Liu
Zhiyuan Yan
Hongfei Zhu
Tao Zhang
机构
[1] Tsinghua University,Department of Energy and Power Engineering
[2] Guodian Science and Technology Research Institute,undefined
来源
Frontiers in Energy | 2022年 / 16卷
关键词
inlet air temperature; inlet guide vane (IGV) opening; part-load; equilibrium running line; gas turbine (GT) efficiency; surge margin (SM);
D O I
暂无
中图分类号
学科分类号
摘要
A novel adjusting method for improving gas turbine (GT) efficiency and surge margin (SM) under part-load conditions is proposed. This method adopts the inlet air heating technology, which uses the waste heat of low-grade heat source and the inlet guide vane (IGV) opening adjustment. Moreover, the regulation rules of the compressor inlet air temperature and the IGV opening are studied comprehensively to optimize GT performance. A model and calculation method for an equilibrium running line is adopted based on the characteristic curves of the compressor and turbine. The equilibrium running lines calculated through the calculation method involve three part-load conditions and three IGV openings with different inlet air temperatures. The results show that there is an optimal matching relationship between IGV opening and inlet air temperature. For the best GT performance of a given load, the IGV could be adjusted according to inlet air temperature. In addition, inlet air heating has a considerable potential for the improvement of part-load performance of GT due to the increase in compressor efficiency, combustion efficiency, and turbine efficiency as well as turbine inlet temperature, when inlet air temperature is lower than the optimal value with different IGV openings. Further, when the IGV is in a full opening state and an optimal inlet air temperature is achieved by using the inlet air heating technology, GT efficiency and SM can be obviously higher than other IGV openings. The IGV can be left unadjusted, even when the load is as low as 50%. These findings indicate that inlet air heating has a great potential to replace the IGV to regulate load because GT efficiency and SM can be remarkably improved, which is different from the traditional viewpoints.
引用
下载
收藏
页码:1000 / 1016
页数:16
相关论文
共 50 条
  • [31] The Effect of Ambient Temperature on a Gas Turbine Performance in Part load Operation
    Baheta, Aklilu Tesfamichael
    Gilani, Syed Ihtsham-Ul-Haq
    4TH INTERNATIONAL MEETING OF ADVANCES IN THERMOFLUIDS (IMAT 2011), PT 1 AND 2, 2012, 1440 : 889 - 893
  • [32] Impact of inlet air cooling on gas turbine performance
    Pyzik, Ewa
    Jarzebowski, Szymon
    Miller, Andrzej
    JOURNAL OF POWER TECHNOLOGIES, 2012, 92 (04): : 249 - 257
  • [33] CALCULATION FOR PART-LOAD OPERATION OF COMBINED GAS-STEAM TURBINE PLANTS
    KEHLHOFER, R
    BROWN BOVERI REVIEW, 1978, 65 (10): : 672 - 679
  • [34] Optimum power boosting of gas turbine cycles with compressor inlet air refrigeration
    AitAli, MA
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1997, 119 (01): : 124 - 130
  • [35] Assessment of Organic Rankine Cycle Part-Load Performance as Gas Turbine Bottoming Cycle with Variable Area Nozzle Turbine Technology
    Motamed, Mohammad Ali
    Nord, Lars O.
    ENERGIES, 2021, 14 (23)
  • [36] Performance characteristics of part-load operations of a solid oxide fuel cell/gas turbine hybrid system using air-bypass valves
    Yang, Jin Sik
    Sohn, Jeong L.
    Ro, Sung Tack
    JOURNAL OF POWER SOURCES, 2008, 175 (01) : 296 - 302
  • [37] EFFECT OF WATER TEMPERATURE ON THE PERFORMANCE OF GAS TURBINE INLET AIR-FOGGING SYSTEMS
    Chaker, Mustapha A.
    Meher-Homji, Cyrus B.
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2013, VOL 5A, 2013,
  • [38] Load-regulation characteristics of gas turbine combined cycle power system controlled with compressor inlet air heating
    Fan, Kunle
    Yang, Cheng
    Xie, Zhuli
    Ma, Xiaoqian
    APPLIED THERMAL ENGINEERING, 2021, 196
  • [39] Experimental Investigation of Micro-Gas Turbine Performance at Reduced Air Inlet Temperature
    Said, Mior Azman
    Hassan, Suhaimi
    Nor, M. Faizairi M.
    UTP-UMP SYMPOSIUM ON ENERGY SYSTEMS 2017 (SES 2017), 2017, 131
  • [40] Part-load thermal efficiency enhancement in gas turbine combined cycles by exhaust gas recirculation
    Motamed, Mohammad Ali
    Genrup, Magnus
    Nord, Lars O.
    APPLIED THERMAL ENGINEERING, 2024, 244