Theoretical analysis of the pressure oscillation phenomena in capillary pumped loop

被引:0
|
作者
Zhang J. [1 ]
Hou Z. [1 ]
Sun C. [1 ]
机构
[1] Beijing Institute of Spacecraft System Engineering, P.O. Box 9628, Beijing
关键词
Capillary pumped loop; Evaporator; Oscillation;
D O I
10.1007/s11630-998-0004-2
中图分类号
学科分类号
摘要
Based on the physical model of capillary pumped loop (CPL) system, the phenomena of pressure oscillation are simplified and analyzed. From a set of non-linear differential equations, the influence of system parameters on the performance of the CPL is discussed, including the working temperature (the set point), loop resistance, vapor volume etc. From the analysis, some measures were taken to improve the performance of the loop. Meanwhile, the reason why the deprive of the CPL occurs during the operation is given by analyzing the theoretical calculation results.
引用
收藏
页码:89 / 96
页数:7
相关论文
共 50 条
  • [21] An experimental investigation on capillary pumped loop with the meshes wick
    Yu, Jianlin
    Chen, Hua
    Zhao, Hua
    Li, Yanzhong
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2007, 50 (21-22) : 4503 - 4507
  • [22] The Phillips Laboratory capillary pumped loop test facility
    Gluck, DF
    Kaylor, MC
    SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM (STAIF-96), PTS 1-3: 1ST CONFERENCE ON COMMERCIAL DEVELOPMENT OF SPACE; 1ST CONFERENCE ON NEXT GENERATION LAUNCH SYSTEMS; 2ND SPACECRAFT THERMAL CONTROL SYMPOSIUM; 13TH SYMPOSIUM ON SPACE NUCLEAR POWER AND PROPULSION - FUTURE SPACE AND EARTH SCIENCE MISSIONS - SPECIAL TOPIC; REMOTE SENSING FOR COMMERCIAL, CIVIL AND SCIENCE APPLICATIONS - SPECIAL TOPIC, 1996, (361): : 739 - 744
  • [23] Thermal performance of a capillary pumped loop for automotive cooling
    Singh, R.
    Akbarzadeh, A.
    Mochizuki, M.
    EXPERIMENTAL HEAT TRANSFER, 2008, 21 (04) : 296 - 313
  • [24] Design, development and testing of a miniature capillary pumped loop
    Dunbar, N
    Jacobs, R
    SIXTH EUROPEAN SYMPOSIUM ON SPACE ENVIRONMENTAL CONTROL SYSTEMS, VOLS 1 AND 2, 1997, 400 : 365 - 370
  • [25] Flight testing of the Capillary Pumped Loop 3 experiment
    Ottenstein, L
    Butler, D
    Ku, JT
    Cheung, K
    Baldauff, R
    Hoang, T
    SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM - STAIF 2003, 2003, 654 : 55 - 64
  • [26] Experimental study of small scale capillary pumped loop
    Chen, Pin-Chih
    Lin, Wei-Keng
    Zhongguo Hangkong Taikong Xuehui Huikan/Transactions of the Aeronautical and Astronautical Society of the Republic of China, 2001, 33 (02): : 103 - 109
  • [27] Modeling of stability of the condensing interface in a capillary pumped loop
    Tu, Zheng-kai
    Pan, Mu
    Liu, Wei
    Liu, Zhi-chun
    Wan, Zhong-min
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (5-6) : 1709 - 1715
  • [28] Transient Modeling of a Capillary Pumped Loop for Terrestrial Applications
    Blet, Nicolas
    Platel, Vincent
    Ayel, Vincent
    Bertin, Yves
    Romestant, Cyril
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2016, 138 (07):
  • [29] Detailed modelling of the evaporator of a capillary pumped loop.
    Platel, V
    Butto, C
    Grandpeix, JY
    Joly, JL
    REVUE GENERALE DE THERMIQUE, 1996, 35 (415): : 434 - 449
  • [30] Effect of the working liquid to the capillary pumped loop performance
    Avgerinos, Nikolaos A.
    Margaris, Dionissios P.
    Tsahalis, Demos T.
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2016, 11 (03) : 393 - 399