Clotrimazole-Triiodide Ion Association as an Ion Exchanger for a Triiodide Ion-Selective Electrode

被引:0
|
作者
Khalil Farhadi
Ramin Maleki
机构
[1] Urmia University,Department of Chemistry, Faculty of Science
来源
Analytical Sciences | 2002年 / 18卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A novel triiodide ion-selective electrode based on a clotrimazole-triiodide ion pair as a membrane carrier was prepared. It has a linear response to triiodide from 8 × 10–6 to 5 × 10–3 M with a slope of–68.9 mV per decade and a detection limit of 5 × 10–6 M. The electrode response is independent of the pH of the solution in the pH range 2–9. It has a very short response time and can be used for at least 3 months without any considerable divergence in the potentials. The proposed sensor revealed very good selectivities for I3– over a variety of other anions. It was used as an indicator electrode in the potentiometric titration of triiodide ions and in an indirect potentiometric determination of clotrimazole in pharmaceutical preparations.
引用
收藏
页码:133 / 136
页数:3
相关论文
共 50 条
  • [21] CESIUM ION-SELECTIVE ELECTRODE
    CHANG, FC
    WU, SC
    HUANG, CH
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 1983, 30 (02) : 91 - 95
  • [22] TRIGGERING OF ION-SELECTIVE ELECTRODE
    FUJIWARA, S
    YUSA, T
    NISHIYAMA, K
    BUNSEKI KAGAKU, 1982, 31 (03) : E135 - E136
  • [23] ANALYSIS OF BROMIDE ION IN WINE BY ION-SELECTIVE ELECTRODE
    GRAF, JE
    VAUGHN, TE
    KIPP, WH
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1976, 59 (01): : 53 - 55
  • [24] Interactions of triiodide cluster ion with solvents
    Zhang, FS
    Lynden-Bell, RM
    EUROPEAN PHYSICAL JOURNAL D, 2005, 34 (1-3): : 129 - 132
  • [25] Interactions of triiodide cluster ion with solvents
    F. S. Zhang
    R. M. Lynden-Bell
    The European Physical Journal D - Atomic, Molecular, Optical and Plasma Physics, 2005, 34 : 129 - 132
  • [26] THE DETERMINATION OF THE MERCURIC ION WITH AN IODIDE ION-SELECTIVE ELECTRODE
    AOMI, T
    DENKI KAGAKU, 1980, 48 (09): : 491 - 494
  • [27] Triiodide ion and alizarin red S as two new reagents for the determination of clotrimazole and ketoconazole
    Farhadi, K
    Maleki, R
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (04) : 1023 - 1033
  • [28] XAFS analysis of triiodide ion in solutions
    Sakane, H
    Mitsui, T
    Tanida, H
    Watanabe, I
    JOURNAL OF SYNCHROTRON RADIATION, 2001, 8 (02) : 674 - 676
  • [29] Ketoconazol-triiodide ion pair complex as a suitable carrier in an iodide selective membrane electrode
    Maleki, Ramin
    Hosseinzadeh, Reza
    Matin, Amir Abbas
    Farhadi, Khalil
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2007, 54 (03) : 699 - 704
  • [30] Ultraviolet absorption spectra of iodine, iodide ion and triiodide ion
    Wei, YJ
    Liu, CG
    Mo, LP
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25 (01) : 86 - 88