Validity and reliability of three commercially available breath-by-breath respiratory systems

被引:0
|
作者
James Carter
Asker E. Jeukendrup
机构
[1] Human Performance Laboratory,
[2] School of Sport and Exercise Sciences,undefined
[3] The University of Birmingham,undefined
[4] Edgbaston,undefined
[5] B15 2TT,undefined
[6] Birmingham,undefined
[7] UK,undefined
来源
关键词
Gas exchange Exercise testing Reproducibility Breath-by-breath measurements On-line systems;
D O I
暂无
中图分类号
学科分类号
摘要
Information concerning the validity and reliability of commercial on-line gas analysis systems is limited. The aim of this study was to provide a comparison of the validity and reliability of three on-line systems (Oxycon Alpha, Oxycon Pro and Pulmolab EX670) with that of Douglas bags. Two separate studies were conducted. In study 1, the three gas analysis systems were compared with Douglas bags using a metabolic simulator over four increases in ventilation. In study 2, ten subjects were split into equal groups exercising at 100 W or 150 W for 85 min on three separate occasions. Each system was used twice per visit. Study 1 demonstrated that the Oxycon Alpha and Douglas bags produced similar respiratory values over all levels of ventilation. The Oxycon Pro tended to slightly overestimate mean expiratory flow (\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$\dot V_{\rm E} $\end{document} ), oxygen uptake (\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$\dot V{\rm O}_{\rm 2} $\end{document} ), carbon dioxide production (\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$\dot V{\rm CO}_{\rm 2} $\end{document} ) and respiratory exchange ratio (RER) at the higher ventilations. The Pulmolab produced large overestimations at all ventilations for \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$\dot V{\rm CO}_{\rm 2} $\end{document} and RER (up to 26.3% away from expectations), whilst values for \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$\dot V_{\rm E} $\end{document} , and \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$\dot V{\rm O}_{\rm 2} $\end{document} were slightly underestimated at higher ventilations (up to 7.5% from expectations). The results of study 2 support the findings of study 1, with the Oxycon Pro and Oxycon Alpha producing similar results compared to Douglas bags for \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$\dot V{\rm O}_{\rm 2} $\end{document} , \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$\dot V{\rm CO}_{\rm 2} $\end{document} and RER. The coefficients of variation for \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$\dot V{\rm O}_{\rm 2} $\end{document} and \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$\dot V{\rm CO}_{\rm 2} $\end{document} measured using Douglas bags, Oxycon Pro and Oxycon Alpha were 3.3–5.1%, 4.7–7.0% and 4.5–6.3%, respectively, whilst that for the Pulmolab was highly variable (26.8–45.8%). The exercise study showed the Oxycon Pro and Oxycon Alpha to be both valid and reliable on-line systems for the measurement of parameters of respiration, at least at workloads up to 150 W.
引用
收藏
页码:435 / 441
页数:6
相关论文
共 50 条
  • [1] Validity and reliability of three commercially available breath-by-breath respiratory systems
    Carter, J
    Jeukendrup, AE
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2002, 86 (05) : 435 - 441
  • [2] Variation of Respiratory Measures with Commercially Available Breath by Breath Systems
    Hodgson, Adrian B.
    Jeukendrup, Asker
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 265 - 266
  • [3] Variation of Respiratory Measures with Commercially Available Breath by Breath Systems
    Hodgson, Adrian B.
    Jeukendrup, Asker
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2012, 27 : 265 - 266
  • [4] Breath-by-breath analysis of respiratory sinus arrhythmia in dogs
    Grosso, Giovanni
    Vezzosi, Tommaso
    Briganti, Angela
    Di Franco, Chiara
    Tognetti, Rosalba
    Mortola, Jacopo P.
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2021, 294
  • [5] VALIDITY AND REPRODUCIBILITY OF BREATH-BY-BREATH ANALYSIS OF RESPIRATORY GAS-EXCHANGE IN PEDIATRIC EXERCISE TESTING
    REYBROUCK, T
    DEROOST, F
    GEWILLIG, M
    VANDERHAUWAERT, L
    JOURNAL OF PHYSIOLOGY-LONDON, 1993, 467 : P26 - P26
  • [6] BREATH-BY-BREATH ANALYSIS OF RESPIRATORY WORK DURING ANESTHESIA
    WEAVER, DC
    ANESTHESIOLOGY, 1967, 28 (01) : 273 - &
  • [7] BREATH-BY-BREATH RESPIRATORY DRIVE DURING PENTOTHALE INDUCTION
    FAIJERSON, B
    LARSSON, M
    CARLSSON, P
    LINNARSSON, D
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1985, 29 : 88 - 88
  • [8] BREATH-BY-BREATH MEASUREMENT OF RESPIRATORY FUNCTIONS - INSTRUMENTATION AND APPLICATIONS
    LAMBERTSEN, CJ
    GELFAND, R
    JOURNAL OF APPLIED PHYSIOLOGY, 1966, 21 (01) : 282 - +
  • [9] Computerized breath-by-breath analysis of respiratory variables during exercise
    Salminen, R.
    Aunola, S.
    Malkia, E.
    Vuori, I.
    1600, (09):
  • [10] Breath-By-Breath Analysis Of Respiratory Sinus Arrhythmia In Preterm Infants
    Shalish, W.
    Rao, S.
    Sant'Anna, G.
    Mortola, J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193