Systematic evaluation of particle loss during handling in the percutaneous transluminal angioplasty for eight different drug-coated balloons

被引:0
|
作者
Andreas Heinrich
Martin S. Engler
Felix V. Güttler
Christian Matthäus
Jürgen Popp
Ulf K.-M. Teichgräber
机构
[1] Jena University Hospital-Friedrich Schiller University,Department of Radiology
[2] Leibniz Institute of Photonic Technology,Institute of Physical Chemistry & Abbe Center of Photonics
[3] Friedrich Schiller University Jena,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Paclitaxel drug coated balloons (DCBs) should provide optimal drug transfer exclusively to the target tissue. The aim of this study was to evaluate the particle loss by handling during angioplasty. A robotic arm was developed for systematic and reproducible drug abrasion experiments. The contact force on eight different commercially available DCB types was gradually increased, and high-resolution microscopic images of the deflated and inflated balloons were recorded. Three types of DCBs were classified: no abrasion of the drug in both statuses (deflated and inflated), significant abrasion only in the inflated status, and significant abrasion in both statuses. Quantitative measurements via image processing confirmed the qualitative classification and showed changes of the drug area between 2.25 and 45.73% (13.28 ± 14.29%) in the deflated status, and between 1.66 and 40.41% (21.43 ± 16.48%) in the inflated status. The structures and compositions of the DCBs are different, some are significantly more susceptible to drug loss. Particle loss by handling during angioplasty leads to different paclitaxel doses in the target regions for same DCB types. Susceptibility to involuntary drug loss may cause side effects, such as varying effective paclitaxel doses, which may explain variations in studies regarding the therapeutic outcome.
引用
收藏
相关论文
共 33 条
  • [31] Comparative Effectiveness of Plain Balloon Angioplasty, Bare Metal Stents, Drug-Coated Balloons, and Drug-Eluting Stents for the Treatment of Infrapopliteal Artery Disease: Systematic Review and Bayesian Network Meta-analysis of Randomized Controlled Trials
    Katsanos, Konstantinos
    Kitrou, Panagiotis
    Spiliopoulos, Stavros
    Diamantopoulos, Athanasios
    Karnabatidis, Dimitris
    JOURNAL OF ENDOVASCULAR THERAPY, 2016, 23 (06) : 851 - 863
  • [32] Drug-coated balloon versus uncoated percutaneous transluminal angioplasty for the treatment of atherosclerotic lesions in the superficial femoral and proximal popliteal artery: 2-year results of the MDT-2113 SFA Japan randomized trial
    Iida, Osamu
    Soga, Yoshimitsu
    Urasawa, Kazushi
    Saito, Shigeru
    Jaff, Michael R.
    Wang, Hong
    Ookubo, Hiroko
    Yokoi, Hiroyoshi
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 93 (04) : 664 - 672
  • [33] Drug-Coated Balloon vs Standard Percutaneous Transluminal Angioplasty for the Treatment of Atherosclerotic Lesions in the Superficial Femoral and Proximal Popliteal Arteries: One-Year Results of the MDT-2113 SFA Japan Randomized Trial
    Iida, Osamu
    Soga, Yoshimitsu
    Urasawa, Kazushi
    Saito, Shigeru
    Jaff, Michael R.
    Wang, Hong
    Ookubo, Hiroko
    Yokoi, Hiroyoshi
    JOURNAL OF ENDOVASCULAR THERAPY, 2018, 25 (01) : 109 - 117