An improved polymer electrolyte-based amperometric hydrogen sensor

被引:0
|
作者
C. Ramesh
G. Velayutham
N. Murugesan
V. Ganesan
K. S. Dhathathreyan
G. Periaswami
机构
[1] Indira Gandhi Centre for Atomic Research,Materials Chemistry Division
[2] Centre For Electrochemical & Energy Research,undefined
[3] Spic Science Foundation,undefined
关键词
Polymer electrolyte; Amperometric method; Hydrogen sensor; Diffusion barrier; Fuel cell;
D O I
暂无
中图分类号
学科分类号
摘要
An improved polymer electrolyte membrane (PEM) fuel cell-based amperometric hydrogen sensor that operates at room temperature has been developed. The electrolyte used in the sensor is a PVA/H3PO4 blend, which is a proton-conducting solid polymer electrolyte. A thin film of palladium is used as the anode and platinum supported on carbon as the cathode. The sensor functions as a fuel cell, H2/Pd//PVA-H3PO4//Pt/O2, and the short-circuit current is found to be linearly related to the hydrogen concentration. The basic principle, details of assembly, response behaviour of the sensor and its application are discussed.
引用
收藏
页码:511 / 516
页数:5
相关论文
共 50 条
  • [41] Solid electrolyte-based NOX sensors
    Thamboon, P
    Yao, S
    Gouma, P
    Akbar, SA
    ELECTROCHEMISTRY OF GLASS AND CERAMICS, 1999, 92 : 221 - 230
  • [42] Effect of the geometry of a working electrode on the behavior of a planar amperometric NO2 sensor based on solid polymer electrolyte
    Kubersky, P.
    Hamacek, A.
    Nespurek, S.
    Soukup, R.
    Vik, R.
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 187 : 546 - 552
  • [43] SOLID-STATE HYDROGEN SENSOR-BASED ON A SOLID-POLYMER ELECTROLYTE
    SAMEC, Z
    OPEKAR, F
    CRIJNS, GJEF
    ELECTROANALYSIS, 1995, 7 (11) : 1054 - 1058
  • [44] Amperometric hydrogen permeation measurement in iron using solid polymer electrolyte fuel cells
    Ng, HC
    Newman, RC
    CORROSION SCIENCE, 2005, 47 (05) : 1197 - 1210
  • [45] Polyacrylonitrile electrolyte-based Li ion batteries
    Abraham, KM
    Choe, HS
    Pasquariello, DM
    ELECTROCHIMICA ACTA, 1998, 43 (16-17) : 2399 - 2412
  • [46] Electrolyte-based on-demand and disposable microbattery
    Lee, KB
    Lin, LW
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2003, 12 (06) : 840 - 847
  • [47] Electrolyte-based ionic control of functional oxides
    Chris Leighton
    Nature Materials, 2019, 18 : 13 - 18
  • [48] Amperometric hydrogen sensor based on pyrrolidinium hydrogen sulfate under anaerobic conditions
    Wang, Rui
    Wu, Ping-Hui
    Zhi, Zi-Nan
    Gao, Wan-Shuo
    Hua, Zhong-Qiu
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 50 (09)
  • [49] A hydrogen sensor based on a hydrogen ion conducting solid electrolyte
    Maffei, N
    Kuriakose, AK
    SENSORS AND ACTUATORS B-CHEMICAL, 1999, 56 (03) : 243 - 246
  • [50] Amperometric biosensor based on redox polymer for measurement of hydrogen peroxide
    State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing 100080, China
    Chin. J. Sens. Actuators, 2006, 3 (549-551):