Usefulness of an automated urinary flow cytometer in mass screening for nephritis

被引:0
|
作者
Kazunari Kaneko
Mutsumi Murakami
Kazumi Shiraishi
Masaru Matsumoto
Kuniaki Yamauchi
Teruo Kitagawa
Yuichiro Yamashiro
机构
[1] Juntendo University Urayasu Hospital,Department of Pediatrics
[2] Nippon Medical School Hospital,Department of Pediatrics
[3] Tokyo Health Service Association,Department of Pediatrics
[4] Juntendo University School of Medicine,undefined
来源
Pediatric Nephrology | 2004年 / 19卷
关键词
Urinary screening; Automated urinary flow cytometer; Glomerular hematuria;
D O I
暂无
中图分类号
学科分类号
摘要
We aimed to assess the utility of a newly developed automated urinary flow cytometer (UFCM) in differentiating the origin of hematuria in the mass screening system for renal diseases in school children. In total, 4,620 children aged 6–14 years with abnormal urinary findings by the screening program in Tokyo were enrolled. Tentative diagnoses were made based on the criteria for this screening program: nephritis in 11, suspected nephritis in 104, hematuria in 771, minimal hematuria in 1,506, proteinuria in 477, urinary tract infection in 83, and healthy in 1,668. Glomerular hematuria, assessed by UFCM, was found in 81.8% of nephritis, 58.7% of suspected nephritis, 59.7% of hematuria, 57.4% of minimal hematuria, 13.4% of proteinuria, and 21.5% of the healthy group. The presence of glomerular hematuria assessed by UFCM had a sensitivity of 61.0%, specificity of 78.5%, positive predictive value of 16.3%, and negative predictive value of 96.7% for the diagnosis of nephritis and suspected nephritis. Thus, our results imply that the absence of glomerular hematuria as assessed by UFCM is highly predictive of the absence of nephritis. If “healthy” children with non-glomerular hematuria by UFCM could be excluded, the total annual cost saving would be approximately 147.4 million JPY, which is equivalent to 5.2% of the current system. In conclusion, a simple, automated and rapid test for glomerular hematuria using UFCM is useful for mass screening. It can precisely predict children with only transient hematuria who do not have any serious illness, and therefore can exclude further unnecessary examinations, resulting in the improvement of cost-effectiveness of the current program.
引用
收藏
页码:499 / 502
页数:3
相关论文
共 50 条
  • [31] The Diagnostic Performance of Urine Flow Cytometer UF1000i for Urinary Tract Infections
    Sun, S. J.
    Zuo, L. L.
    Liu, P. P.
    Wang, X. M.
    He, M. L.
    Wu, S. Y.
    CLINICAL LABORATORY, 2018, 64 (09) : 1395 - 1401
  • [32] AN APPROACH TO AUTOMATED MASS SCREENING OF DENTAL RADIOGRAPHS
    SHAPIRO, M
    NEGIN, M
    FEDERATION PROCEEDINGS, 1970, 29 (02) : A945 - +
  • [33] AUTOMATED MASS SCREENING FOR CARIES - PROGRESS REPORT
    SHAPIRO, M
    SUN, HH
    JOURNAL OF DENTAL RESEARCH, 1973, 52 : 266 - &
  • [34] URINARY CYTOLOGY AS A TEST IN MASS-SCREENING
    NEMOTO, R
    KATO, T
    SHIBATA, K
    KANO, M
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1981, 135 (01): : 115 - 116
  • [35] Mass urinary screening for Fabry disease: Is it feasible?
    Auray-Blais, Christiane
    Cyr, Denis
    Clarke, Joe T. R.
    Drouin, Rigen
    MOLECULAR GENETICS AND METABOLISM, 2008, 93 (02) : S15 - S15
  • [36] Automated mass spectrometric analysis of urinary and plasma serotonin
    de Jong, Wilhelmina H. A.
    Wilkens, Marianne H. L. I.
    de Vries, Elisabeth G. E.
    Kema, Ido P.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (07) : 2609 - 2616
  • [37] Automated mass spectrometric analysis of urinary and plasma serotonin
    Wilhelmina H. A. de Jong
    Marianne H. L. I. Wilkens
    Elisabeth G. E. de Vries
    Ido P. Kema
    Analytical and Bioanalytical Chemistry, 2010, 396 : 2609 - 2616
  • [38] Usefulness of mass screening for ovarian carcinoma using transvaginal ultrasonography
    Sato, S
    Yokoyama, Y
    Sakamoto, T
    Futagami, M
    Saito, Y
    CANCER, 2000, 89 (03) : 582 - 588
  • [39] Evaluation of the sysmex UF-5000 fluorescence flow cytometer as a screening platform for ruling out urinary tract infections in elderly patients presenting at the Emergency Department
    Alenkaer, Lasse Krogh
    Pedersen, Lise
    Szecsi, Pal Bela
    Bjerrum, Poul Jannik
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2021, 81 (05): : 379 - 384
  • [40] Development of a flow cytometer-based in vitro compartmentalization screening platform for directed protein evolution
    Wirtz, Georgette
    Pitzler, Christian
    Vojcic, Ljubica
    Martinez, Ronny
    Schwaneberg, Ulrich
    NEW BIOTECHNOLOGY, 2014, 31 : S149 - S149