Equipotency of insulin glargine and regular human insulin on glucose disposal in healthy subjects following intravenous infusion

被引:0
|
作者
H. E. Scholtz
S. G. Pretorius
D. H. Wessels
C. Venter
M. A. Potgieter
R. H. A. Becker
机构
[1] Farmovs-Parexel Clinical Research Organisation,
[2] Aventis Pharma Deutschland,undefined
来源
Acta Diabetologica | 2003年 / 40卷
关键词
Equimolar; Insulin glargine; Human insulin;
D O I
暂无
中图分类号
学科分类号
摘要
The absolute glucose disposal of insulin glargine (Lantus) was compared to that of regular human insulin in healthy subjects (n=20) using the euglycaemic clamp technique in a single-dose, double-blind, randomized, two-way crossover design. Subjects received 30-minute intravenous infusions of insulin glargine (0.1 IU/kg) or human insulin (0.1 IU/kg) and a 20% glucose solution infused at a variable rate to maintain euglycaemia at the subject’s baseline glucose level. At equal baseline blood glucose levels (4.42 mmol/l [range, 4.00–5.16 mmol/l] and 4.42 mmol/l [range, 4.01–4.94 mmol/l], respectively), the area under the glucose infusion rate (GIR) time curves from 0–6 hours (AUC(0–6h)) was within the bioequivalence range (insulin glargine, 663.92 mg/kg; human insulin, 734.85 mg/kg). Both the time to maximum GIR and the suppression of serum C-peptide were similar with insulin glargine and human insulin. The resulting maximum serum insulin concentrations (Cmax) were 151.16 µIU/ml and 202.23 µIU/ml, and the time to Cmax (Tmax) was 30 minutes (the duration of the infusion). The observed differences in the Cmax (the mean value for insulin glargine was about 25% lower than that of human insulin) could be explained by lower cross-reactivity of insulin glargine in the human insulin radioimmunoassay. The employed intravenous route, though definitely not the intended clinical use of insulin glargine, provided the clinical evidence in healthy subjects that on a molar basis insulin glargine is equipotent to regular human insulin regarding glucose disposal.
引用
收藏
页码:156 / 162
页数:6
相关论文
共 50 条
  • [21] Effect of inhaled insulin versus matched intravenous infusion on hepatic glucose balance following intraportal glucose infusion in dogs
    Edgerton, DS
    Cherrington, AD
    Neal, DW
    Scott, M
    Glass, D
    Bowen, LE
    Wilson, W
    Hobbs, CH
    Leach, C
    Sivakumaran, S
    Strack, TR
    DIABETOLOGIA, 2004, 47 : A313 - A313
  • [22] FOREARM INSULIN UPTAKE IN HEALTHY-SUBJECTS AFTER ORAL GLUCOSE AND INTRAVENOUS GLIPIZIDE
    NYGREN, A
    LINDBLAD, LE
    SUNDBLAD, L
    ACTA ENDOCRINOLOGICA, 1981, 98 (03): : 407 - 412
  • [23] Physiological responses during hypoglycaemia induced by regular human insulin or a novel human analogue, insulin glargine
    Dagogo-Jack, S
    Askari, H
    Morrill, B
    Lehner, LL
    Kim, B
    Sha, X
    DIABETES OBESITY & METABOLISM, 2000, 2 (06): : 373 - 383
  • [24] Glargine and regular human insulin similarly acutely enhance endothelium-dependent vasodilatation in normal subjects
    Westerbacka, J
    Bergholm, R
    Tiikkainen, M
    Yki-Järvinen, H
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2004, 24 (02) : 320 - 324
  • [25] INSULIN SENSITIVITY AND GLUCOSE DISPOSAL IN YOUNG NORMOGLYCEMIC OBESE SUBJECTS
    BURNAND, B
    HURNI, M
    JEQUIER, E
    DIABETES & METABOLISM, 1982, 8 (01) : 9 - 14
  • [26] EFFECT OF ATROPINE ON INSULIN RELEASE CAUSED BY ORAL AND INTRAVENOUS GLUCOSE IN HUMAN SUBJECTS
    HENDERSON, JR
    JEFFERYS, DB
    JONES, RH
    STANLEY, D
    ACTA ENDOCRINOLOGICA, 1976, 83 (04): : 772 - 780
  • [27] Equipotency of insulin glargine 300 and 100U/mLwith intravenous dosing but differential bioavailability with subcutaneous dosing in dogs
    Werner, Ulrich
    Tennagels, Norbert
    Fanelli, Carmine G.
    Bolli, Geremia B.
    DIABETES OBESITY & METABOLISM, 2021, 23 (01): : 166 - 174
  • [28] Blood Glucose, Insulin and Inorganic Phosphorus in Healthy and Ketotic Dairy Cows after Intravenous Infusion of Glucose Solution
    Djokovic, Radojica
    Samanc, Horea
    Ilic, Zoran
    Kurcubic, Vladimir
    ACTA VETERINARIA BRNO, 2009, 78 (03) : 449 - 453
  • [29] Intravenous glargine and regular insulin have similar effects on endogenous glucose output and peripheral activation/deactivation kinetic profiles
    Mudaliar, S
    Mohideen, P
    Deutsch, R
    Ciaraldi, TP
    Armstrong, D
    Kim, B
    Sha, X
    Henry, RR
    DIABETES CARE, 2002, 25 (09) : 1597 - 1602
  • [30] INSULIN SECRETION DURING CONTINUOUS GLUCOSE INFUSION IN PATIENTS WITH HEPATITIS OR CIRRHOSIS OF LIVER AND IN HEALTHY SUBJECTS
    KNEER, P
    FRERICHS, H
    CREUTZFE.W
    DIABETOLOGIA, 1970, 6 (06) : 634 - &