Use of virtual monoenergetic images for reduction of extensive dental implant associated artifacts in photon-counting detector CT

被引:0
|
作者
Yannik C. Layer
Narine Mesropyan
Patrick A. Kupczyk
Julian A. Luetkens
Alexander Isaak
Tatjana Dell
Benjamin P. Ernst
Ulrike I. Attenberger
Daniel Kuetting
机构
[1] University Hospital Bonn,Department of Diagnostic and Interventional Radiology
[2] University Hospital Bonn,Department of Otorhinolaryngology
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Aim of this study was to assess the impact of virtual monoenergetic images (VMI) on dental implant artifacts in photon-counting detector computed tomography (PCD-CT) compared to standard reconstructed polychromatic images (PI). 30 scans with extensive (≥ 5 dental implants) dental implant-associated artifacts were retrospectively analyzed. Scans were acquired during clinical routine on a PCD-CT. VMI were reconstructed for 100–190 keV (10 keV steps) and compared to PI. Artifact extent and assessment of adjacent soft tissue were rated using a 5-point Likert grading scale for qualitative assessment. Quantitative assessment was performed using ROIs in most pronounced hypodense and hyperdense artifacts, artifact-impaired soft tissue, artifact-free fat and muscle tissue. A corrected attenuation was calculated as difference between artifact-impaired tissue and tissue without artifacts. Qualitative assessment of soft palate and cheeks improved for all VMI compared to PI (Median PI: 1 (Range: 1–3) and 1 (1–3); e.g. VMI130 keV 2 (1–5); p < 0.0001 and 2 (1–4); p < 0.0001). In quantitative assessment, VMI130 keV showed best results with a corrected attenuation closest to 0 (PI: 30.48 ± 98.16; VMI130 keV: − 0.55 ± 73.38; p = 0.0026). Overall, photon-counting deducted VMI reduce the extent of dental implant-associated artifacts. VMI of 130 keV showed best results and are recommended to support head and neck CT scans.
引用
收藏
相关论文
共 50 条
  • [31] The first mobile photon-counting detector CT: the human images and technical performance study
    Park, Su-Jin
    Park, Junyoung
    Kim, Doil
    Lee, Duhgoon
    Lee, Chang-Lae
    Bechwati, Ibrahim
    Wu, Dufan
    Gupta, Rajiv
    Jung, Jinwook
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (09):
  • [32] Optimisation of virtual monoenergetic reconstructions for the diagnosis of pulmonary embolism using photon-counting detector computed tomography angiography
    Chamberlin, Jordan H.
    Toth, Adrienn
    Hinen, Shaun
    O'Doherty, Jim
    Baruah, Dhiraj
    Maisuria, Dhruw
    Mcguire, Aaron
    Knight, Heather
    Schoepf, U. Joseph
    Munden, Reginald F.
    Kabakus, Ismail M.
    POLISH JOURNAL OF RADIOLOGY, 2024, 89 : e63 - e69
  • [33] Photon-counting detector computed tomography: iodine density versus virtual monoenergetic imaging of pancreatic ductal adenocarcinoma
    Zlatan Alagic
    Carlos Valls Duran
    Chikako Suzuki
    Kolbeinn Halldorsson
    Anders Svensson-Marcial
    Rebecca Saeter
    Seppo K. Koskinen
    Abdominal Radiology, 2025, 50 (4) : 1720 - 1730
  • [34] Metal artifacts from sternal wires: evaluation of virtual monoenergetic images from spectral-detector CT for artifact reduction
    Laukamp, Kai Roman
    Hokamp, Nils Grosse
    Alabar, Omar
    Obmann, Verena Carola
    Lennartz, Simon
    Zopfs, David
    Gilkeson, Robert
    Ramaiya, Nikhil
    Gupta, Amit
    CLINICAL IMAGING, 2020, 60 (02) : 249 - 256
  • [35] Photon-Counting Detector CT for Liver Lesion Detection-Optimal Virtual Monoenergetic Energy for Different Simulated Patient Sizes and Radiation Doses
    Racine, Damien
    Mergen, Victor
    Viry, Anais
    Frauenfelder, Thomas
    Alkadhi, Hatem
    Vitzthum, Veronika
    Euler, Andre
    INVESTIGATIVE RADIOLOGY, 2024, 59 (08) : 554 - 560
  • [36] Virtual monochromatic imaging with projection-based material decomposition algorithm for metal artifacts reduction in photon-counting detector computed tomography
    Chang, Chia-Hao
    Wu, Hsiang-Ning
    Hsu, Ching-Han
    Lin, Hsin-Hon
    PLOS ONE, 2023, 18 (03):
  • [37] Photon-counting Detector CT with Deep Learning Noise Reduction to Detect Multiple Myeloma
    Baffour, Francis I.
    Huber, Nathan R.
    Ferrero, Andrea
    Rajendran, Kishore
    Glazebrook, Katrina N.
    Larson, Nicholas B.
    Kumar, Shaji
    Cook, Joselle M.
    Leng, Shuai
    Shanblatt, Elisabeth R.
    McCollough, Cynthia H.
    Fletcher, Joel G.
    RADIOLOGY, 2023, 306 (01) : 229 - 236
  • [38] Combining virtual monoenergetic imaging and iterative metal artifact reduction in first-generation photon-counting computed tomography of patients with dental implants
    Patzer, Theresa Sophie
    Kunz, Andreas Steven
    Huflage, Henner
    Gruschwitz, Philipp
    Pannenbecker, Pauline
    Afat, Saif
    Herrmann, Judith
    Petritsch, Bernhard
    Bley, Thorsten Alexander
    Grunz, Jan-Peter
    EUROPEAN RADIOLOGY, 2023, 33 (11) : 7818 - 7829
  • [39] Triple-energy virtual monochromatic imaging with a photon-counting detector for reducing metal artifacts in half-beam dental computed tomography
    Lee, M.
    Lee, H.
    Lee, S.
    Kim, W.
    Lim, Y.
    Choa, H.
    Cha, B.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (11):
  • [40] Metal artifact reduction in patients with total hip replacements: evaluation of clinical photon counting CT using virtual monoenergetic images
    Schreck, Julian
    Laukamp, Kai Roman
    Niehoff, Julius Henning
    Michael, Arwed Elias
    Boriesosdick, Jan
    Woeltjen, Matthias Michael
    Kroeger, Jan Robert
    Reimer, Robert P. P.
    Grunz, Jan-Peter
    Borggrefe, Jan
    Lennartz, Simon
    EUROPEAN RADIOLOGY, 2023, 33 (12) : 9286 - 9295