A novel iterative reconstruction algorithm allows reduced dose multidetector-row CT imaging of mechanical prosthetic heart valves

被引:0
|
作者
Jesse Habets
Petr Symersky
Bas A. J. M. de Mol
Willem P. Th. M. Mali
Tim Leiner
Ricardo P. J. Budde
机构
[1] University Medical Center Utrecht,Department of Radiology
[2] Academic Medical Center,Department of Cardiothoracic Surgery
关键词
Prosthetic heart valve; Computed tomography; Iterative reconstruction; Artifacts; Image noise; Reconstruction algorithm;
D O I
暂无
中图分类号
学科分类号
摘要
Multidetector-row CT is promising for prosthetic heart valve (PHV) assessment but retrospectively ECG-gated scanning has a considerable radiation dose. Recently introduced iterative reconstruction (IR) algorithms may enable radiation dose reduction with retained image quality. Furthermore, PHV image quality on the CT scan mainly depends on extent of PHV artifacts. IR may decrease streak artifacts. We compared image noise and artifact volumes in scans of mechanical PHVs reconstructed with conventional filtered back projection (FBP) to lower dose scans reconstructed with IR. Four different PHVs (St. Jude, Carbomedics, ON-X and Medtronic Hall) were scanned in a pulsatile in vitro model. Ten retrospectively ECG-gated CT scans were performed of each PHV at 120 kV, 600 mAs (high-dose CTDIvol 35.3 mGy) and 120 kV, 300 mAs (low-dose CTDIvol 17.7 mGy) on a 64 detector-row scanner. Diastolic and systolic images were reconstructed with FBP (high and low-dose) and the IR algorithm (low-dose only). Hypo- and hyperdense artifact volumes were determined using two threshold filters. Image noise was measured. Mean hypo- and hyperdense artifact volumes (mm3) were 1,235/5,346 (high-dose FBP); 2,405/6,877 (low-dose FBP) and 1,218/5,333 (low-dose IR). Low-dose IR reconstructions had similar image noise compared to high-dose FBP (16.5 ± 1.7 vs. 16.3 ± 1.6, mean ± SD, respectively, P = 1.0). IR allows ECG-gated PHV imaging with similar image noise and PHV artifacts at 50% less dose compared to conventional FBP in an pulsatile in vitro model.
引用
收藏
页码:1567 / 1575
页数:8
相关论文
共 43 条
  • [1] A novel iterative reconstruction algorithm allows reduced dose multidetector-row CT imaging of mechanical prosthetic heart valves
    Habets, Jesse
    Symersky, Petr
    de Mol, Bas A. J. M.
    Mali, Willem P. Th. M.
    Leiner, Tim
    Budde, Ricardo P. J.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (06): : 1567 - 1575
  • [2] Multidetector-Row Computed Tomography Imaging Characteristics of Mechanical Prosthetic Valves
    Symersky, Petr
    Budde, Ricardo P. J.
    Prokop, Mathias
    de Mol, Bas A. J. M.
    JOURNAL OF HEART VALVE DISEASE, 2011, 20 (02): : 216 - 222
  • [3] Prosthetic heart valve assessment with multidetector-row CT: imaging characteristics of 91 valves in 83 patients
    Habets, Jesse
    Symersky, Petr
    van Herwerden, Lex A.
    de Mol, Bas A. J. M.
    Spijkerboer, Anje M.
    Mali, Willem P. Th. M.
    Budde, Ricardo P. J.
    EUROPEAN RADIOLOGY, 2011, 21 (07) : 1390 - 1396
  • [4] Prosthetic heart valve assessment with multidetector-row CT: imaging characteristics of 91 valves in 83 patients
    Jesse Habets
    Petr Symersky
    Lex A. van Herwerden
    Bas A. J. M. de Mol
    Anje M. Spijkerboer
    Willem P. Th. M. Mali
    Ricardo P. J. Budde
    European Radiology, 2011, 21 : 1390 - 1396
  • [5] A pulsatile in-vitro model to establish multidetector-row computed tomography imaging characteristics of mechanical prosthetic valves
    Symersky, P.
    Budde, R. P. J.
    Prokop, M.
    De Mol, B. A. J. M.
    EUROPEAN HEART JOURNAL, 2010, 31 : 293 - 293
  • [6] Multidetector-row CT image quality and radiation dose: Imaging the lung
    Judy, PF
    SEMINARS IN ROENTGENOLOGY, 2003, 38 (02) : 186 - 192
  • [7] Multidetector-Row Computed Tomography Allows Accurate Measurement of Mechanical Prosthetic Heart Valve Leaflet Closing Angles Compared With Fluoroscopy
    Sucha, Dominika
    Symersky, Petr
    Vonken, Evert-Jan P. A.
    Provoost, Esther
    Chamuleau, Steven A. J.
    Budde, Ricardo P. J.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (03) : 451 - 456
  • [8] Use of multidetector-row computed tomography scan to detect pannus formation in prosthetic mechanical aortic valves
    Aladmawi, Mohamed A.
    Pragliola, Claudio
    Vriz, Olga
    Galzerano, Domenico
    JOURNAL OF THORACIC DISEASE, 2017, 9 : S343 - S348
  • [9] Multidetector CT imaging of mechanical prosthetic heart valves: quantification of artifacts with a pulsatile in-vitro model
    Symersky, Petr
    Budde, Ricardo P. J.
    Westers, Paul
    de Mol, Bas A. J. M.
    Prokop, Mathias
    EUROPEAN RADIOLOGY, 2011, 21 (10) : 2103 - 2110
  • [10] Multidetector CT imaging of mechanical prosthetic heart valves: quantification of artifacts with a pulsatile in-vitro model
    Petr Symersky
    Ricardo P. J. Budde
    Paul Westers
    Bas A. J. M. de Mol
    Mathias Prokop
    European Radiology, 2011, 21 : 2103 - 2110