Galvanic Corrosion in Molten Salts: A Discussion of the Corrosion Mechanism of Two-Phase Ni–20Cr–20/30Cu Alloys in Eutectic (Li,K)2CO3 at 650°C

被引:0
|
作者
C. L. Zeng
J. Li
T. Zhou
机构
[1] Chinese Academy of Sciences,State Key Laboratory for Corrosion and Protection, Institute of Metal Research
来源
Oxidation of Metals | 2005年 / 64卷
关键词
Ternary Ni–Cr–Cu alloys; molten (Li, K); CO; galvanic corrosion; two-phase structure;
D O I
暂无
中图分类号
学科分类号
摘要
The corrosion of a Ni–20Cr and three ternary Ni–20Cr–Cu alloys containing 10, 20 and 30 wt.% Cu, respectively, in a eutectic (Li, K)2CO3 melt was studied at 650°C under air. Ni–20Cr and Ni–20Cr–10Cu are solid-solution alloys, while both Ni–20Cr–20Cu and Ni–20Cr–30Cu are two-phase alloys composed of a Cu-depleted matrix together with a small amount of a Cu-rich phase. The results indicate that Ni–20Cr and Ni–20Cr–10Cu have similar corrosion rates, forming a scale of external NiO and inner Cr-rich oxides. The two-phase Ni–20Cr–20/30 Cu alloys corrode rapidly, producing a mixture of Ni–Cr–rich oxides and a Ni–Cu metallic phase, which may be ascribed to the accelerated corrosion of the Cu-depleted matrix coupled with the cathodic Cu-rich phase of the alloys. As compared to Ni–20Cr–30Cu, Ni–20Cr–20Cu suffers from more-severe corrosion, due to a smaller area fraction of the cathodic Cu-rich phase in the alloy. The galvanic corrosion mechanism is also discussed.
引用
收藏
页码:207 / 218
页数:11
相关论文
共 24 条
  • [1] Galvanic corrosion in molten salts:: A discussion of the corrosion mechanism of two-phase Ni-20Cr-20/30Cu alloys in eutectic (Li,K)2CO3 at 650°C
    Zeng, CL
    Li, J
    Zhou, T
    OXIDATION OF METALS, 2005, 64 (3-4): : 207 - 218
  • [2] The corrosion behavior of two-phase Ni-Dy alloys in a eutectic (Li,K)2CO3 mixture at 650 ○C
    Zeng, CL
    Zhang, T
    Guo, PY
    Wu, WT
    CORROSION SCIENCE, 2004, 46 (09) : 2183 - 2189
  • [3] Study of the corrosion of Fe-Cr alloys in molten (Li-K)2CO3 at 650 °C
    Zeng, Chaoliu
    Wang, Wen
    Wu, Weitao
    Jinshu Xuebao/Acta Metallurgica Sinica, 2000, 36 (06): : 651 - 654
  • [4] Effects of Silicon and Water Vapour on Corrosion of Fe–20Cr and Fe–20Cr–20Ni Alloys in CO2 at 650 °C
    Thuan Dinh Nguyen
    Jianqiang Zhang
    David J. Young
    Oxidation of Metals, 2017, 87 : 541 - 573
  • [5] Corrosion of Ni-Ti alloys in the molten (Li,K)2CO3 eutectic mixture
    Zeng, CL
    Wu, WT
    CORROSION SCIENCE, 2002, 44 (01) : 1 - 12
  • [6] Electrochemical impedance of two-phase Ni-Ti alloys during corrosion in eutectic (0.62Li, 0.38K)2CO3 at 650 °C
    Zeng, CL
    Guo, PY
    Wu, WT
    ELECTROCHIMICA ACTA, 2004, 49 (14) : 2271 - 2277
  • [7] Electrochemical impedance spectra for the corrosion of two-phase Cu-15Al alloy in eutectic (Li, K)2CO3 at 650 °C in air
    Zeng, CL
    Guo, PY
    Wu, WT
    ELECTROCHIMICA ACTA, 2004, 49 (9-10) : 1445 - 1450
  • [8] Electrochemical Impedance Spectroscopy Studies of Corrosion of Two-phase Ni-Dy Alloys in Molten (0.62Li,0.38K)2CO3 at 650 °C
    Liu, S. N.
    Su, W.
    Lv, W. Y.
    Wei, Z. F.
    Zeng, C. L.
    HIGH TEMPERATURE MATERIALS AND PROCESSES, 2013, 32 (05) : 443 - 449
  • [9] Corrosion behavior of pre-oxidized Ni-Ti alloys in eutectic (Li, K)2CO3 mixture at 650 °C
    Zeng, CL
    Zhou, T
    Wu, WT
    JOURNAL OF MATERIALS SCIENCE LETTERS, 2002, 21 (12) : 907 - 909
  • [10] Electrochemical impedance study of the corrosion of Fe-Cr alloys in molten (Li,K)2CO3 eutectic mixture
    Zeng, CL
    Wang, W
    Niu, Y
    Wu, WT
    HIGH TEMPERATURE CORROSION AND PROTECTION OF MATERIALS 5, PTS 1 AND 2, 2001, 369-3 : 809 - 816