Assessment of absorbed dose of gamma rays using the simultaneous determination of inactive hemoglobin derivatives as a biological dosimeter

被引:0
|
作者
A. M. M. Attia
W. M. Aboulthana
G. M. Hassan
E. Aboelezz
机构
[1] National Research Centre,Genetic Engineering and Biotechnology Division, Biochemistry Department
[2] National Institute of Standards,Division of Thermometry and Ionizing Radiation Metrology, Department of Ionizing Radiation Metrology
来源
关键词
Biological dosimetry; γ-Irradiation; Carboxyhemoglobin (HbCO); Methemoglobin (MetHb); Oxyhemoglobin (HbO; ); Sulfhemoglobin (SHb);
D O I
暂无
中图分类号
学科分类号
摘要
Biological dosimetry based on sulfhemoglobin (SHb), methemoglobin (MetHb), and carboxyhemoglobin (HbCO) levels was evaluated. SHb, MetHb and HbCO levels were estimated in erythrocytes of mice irradiated by γ rays from a 60Co source using the method of multi-component spectrophotometric analysis developed recently. In this method, absorption measurements of diluted aqueous Hb-solution were made at λ = 500, 569, 577 and 620 nm, and using the mathematical formulas based on multi-component spectrophotometric analysis and the mathematical Gaussian elimination method for matrix calculation, the concentrations of various Hb-derivatives and total Hb in mice blood were estimated. The dose range of γ rays was from 0.5 to 8 Gy and the dose rate was 0.5 Gy min−1. Among all Hb-derivatives, MetHb, SHb and HbCO demonstrated an unambiguous dose-dependent response. For SHb and MetHb, the detection limits were about 0.5 Gy and 1 Gy, respectively. After irradiation, high levels of MetHb, SHb and HbCO persisted for at least 10 days, and the maximal increase of MetHb, SHb and HbCO occurred up to 24 h following γ irradiation. The use of this “MetHb + SHb + HbCO”-derivatives-based absorbed dose relationship showed a high accuracy. It is concluded that simultaneous determination of MetHb, SHb and HbCO, by multi-component spectrophotometry provides a quick, simple, sensitive, accurate, stable and inexpensive biological indicator for the early assessment of the absorbed dose in mice.
引用
收藏
页码:131 / 144
页数:13
相关论文
共 23 条
  • [1] Assessment of absorbed dose of gamma rays using the simultaneous determination of inactive hemoglobin derivatives as a biological dosimeter
    Attia, A. M. M.
    Aboulthana, W. M.
    Hassan, G. M.
    Aboelezz, E.
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2020, 59 (01) : 131 - 144
  • [2] ASSESSMENT OF ABSORBED DOSE FROM-GAMMA RAYS AND FAST-NEUTRONS WITH A SURFACE DOSIMETER
    CLIFFORD, CE
    FACEY, RA
    PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (06): : 887 - &
  • [3] Ionometric determination of absorbed dose to water for cobalt-60 gamma rays
    Boutillon, M.
    Perroche, A.-M.
    Physics in Medicine and Biology, 1993, 38 (03):
  • [4] IONOMETRIC DETERMINATION OF ABSORBED DOSE TO WATER FOR CO-60 GAMMA-RAYS
    BOUTILLON, M
    PERROCHE, AM
    PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (03): : 439 - 454
  • [5] Determination of a Dose Absorbed in a Biological Sample under Mixed Gamma–Neutron Irradiation
    S. S. Arzumanov
    V. V. Safronov
    A. N. Strepetov
    Technical Physics, 2018, 63 : 1533 - 1536
  • [6] Determination of absorbed dose in CDTN gamma irradiator using Fricke dosimeters
    Centro de Desenvolvimento da Tecnologia Nuclear - CDTN, Comissão Nacional de Energia Nuclear - CNEN, Belo Horizonte, Brazil
    Int. J. Nucl. Energy Sci. Technol., 2 (105-115):
  • [7] Determination of a Dose Absorbed in a Biological Sample under Mixed Gamma-Neutron Irradiation
    Arzumanov, S. S.
    Safronov, V. V.
    Strepetov, A. N.
    TECHNICAL PHYSICS, 2018, 63 (10) : 1533 - 1536
  • [8] PERTURBATION CORRECTION FOR THE IONOMETRIC DETERMINATION OF ABSORBED DOSE IN A GRAPHITE PHANTOM FOR CO-60 GAMMA-RAYS
    BOUTILLON, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (04): : 375 - 388
  • [9] ABSORBED DOSE DETERMINATION OF ORTHOVOLTAGE X-RAYS USING PHOTON ENERGY FLUENCE CALORIMETER
    RAO, ISS
    NAIK, SB
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1984, 35 (01): : 15 - 20
  • [10] Determination of volume averaging correction factors using an elliptical absorbed dose model for Gamma Knife Perfexion
    Segedin, Nikola
    Hrsak, Hrvoje
    Babic, Sanja Dolanski
    Jurkovic, Slaven
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (10):