Optimum Auxiliary Fan Location to Control Air Recirculation

被引:0
|
作者
Ramakrishna Morla
Shivakumar Karekal
Ajit Godbole
Purushotham Tukkaraja
Ping Chang
机构
[1] Norton Gold Fields,Department of Mining Engineering and Management
[2] School of Civil,undefined
[3] Mining and Environmental Engineering,undefined
[4] University of Wollongong,undefined
[5] South Dakota School of Mines,undefined
[6] WA School of Mines: Minerals,undefined
[7] Energy and Chemical Engineering,undefined
[8] Curtin University,undefined
来源
关键词
Dead end; Recirculation; Auxiliary fan; Crosscut; DPF; DPM; CFD simulation;
D O I
暂无
中图分类号
学科分类号
摘要
This paper presents the optimum auxiliary fan(s) location to control air recirculation in dead-end workings where diesel-powered vehicles operate. Investigations were conducted with various secondary fan locations from the dead-end crosscut with varying the intake air quantities using a 30 m3/s capacity twin 75 kW auxiliary fan and 45 m3/s capacity twin 110 kW auxiliary fan to control air recirculation and DPM. The results showed that if the drive intake airflow rate matches the fan capacity, air recirculation will occur even when the fan is located 10 m away from the crosscut entry. Results also showed that if the intake drive air quantity was greater than or equal to 150% of fan capacity, no recirculation was observed when the twin 75 kW fan location was at least 5 m and the twin 110 kW fan location was at least 10 m away from the dead-end crosscut access.
引用
收藏
页码:2291 / 2299
页数:8
相关论文
共 50 条
  • [31] Optimum condition search for tangential flow fan integrated to an air conditioning system with a diffusing ceiling
    Funfschilling, O
    Lenat, Y
    INTER-NOISE 96 - THE 1996 INTERNATIONAL CONGRESS ON NOISE CONTROL ENGINEERING, 25TH ANNIVERSARY CONGRESS - LIVERPOOL, PROCEEDINGS, BOOKS 1-6: NOISE CONTROL - THE NEXT 25 YEARS, 1996, : 1851 - 1854
  • [33] Parameter optimization and control of air suspension with adjustable auxiliary chamber
    Li, Zhongxing
    Ju, Longyu
    Jiang, Hong
    Huang, Dingshi
    Qiche Gongcheng/Automotive Engineering, 2015, 37 (08): : 941 - 945
  • [34] Selection of fan or fan location in ventilation of long drivages
    Sarac, S
    Onder, M
    COMPUTER APPLICATIONS IN THE MINERALS INDUSTRIES, 2001, : 543 - 548
  • [35] Selection of fan or fan location in ventilation of long drivages
    Onder, M
    MINE PLANNING AND EQUIPMENT SELECTION 2000, 2000, : 105 - 109
  • [36] Noise characterization of automotive auxiliary fan drives
    Hofmann, Stefan
    Leitner, Stefan
    Mosshammer, Markus
    Muetze, Annette
    ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2020, 137 (4-5): : 235 - 241
  • [37] FOUNDRY PROCESS AIR RECIRCULATION
    POTOKAR, RW
    JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1979, 29 (01): : 18 - 20
  • [39] BATCH DRYNG WITH AIR RECIRCULATION
    KEEY, RB
    CHEMICAL ENGINEERING SCIENCE, 1968, 23 (11) : 1299 - &
  • [40] Air Recirculation in Coastal Regions
    Surkova, G.
    Salikhova, N.
    MEDCOAST 09: NINTH INTERNATIONAL CONFERENCE ON THE MEDITERRANEAN COASTAL ENVIRONMENT, VOLS 1 AND 2, 2009, : 1001 - 1006