Experimental and Analytical Behavior of Square CFDST Column Blind Bolted to Steel Beam Connections

被引:0
|
作者
Jingfeng Wang
Lei Guo
机构
[1] Hefei University of Technology,School of Civil Engineering
[2] Anhui Civil Engineering Structures and Materials Laboratory,undefined
关键词
Concrete filled double-skin steel tube (CFDST) column joint; Blind fasteners; FE analytical modelling; Parametric analysis;
D O I
暂无
中图分类号
学科分类号
摘要
In recent years, steel or composite beam-column connections adopting blind fasteners have drawn increasing praise due to the rapid development of assembled steel structures. However, limited researches have paid attention to the experimental and analytical behavior of concrete filled double-skin steel tube (CFDST) column blind bolted joints. For investigating the structural performance and seismic behavior of this type of connection, cyclic tests on blind bolted joints to square CFDST columns were carried out to explore the effects of column hollow ratio and end plate type. Finite element analytical modelling of the semi-rigid joint was performed considering complex contact interactions and material models. Good agreement between the test and analytical results was observed in terms of the failure modes and the hysteretic behavior. Substantial parametric analyses were conducted on typical CFDST column connections to observe the influence of parameters including strength of steel tube, column hollow ratio and bolt pretension force. Furthermore, certain constructional measures commonly employed in engineering practice were also discussed. It was concluded that the CFDST column blind bolted to the steel beam joint has favorable seismic behavior and is feasible for application in high-intensity earthquake regions.
引用
收藏
页码:612 / 635
页数:23
相关论文
共 50 条
  • [21] Bolted large seismic steel beam-to-column connections Part 1: experimental study
    Popov, EP
    Takhirov, SM
    ENGINEERING STRUCTURES, 2002, 24 (12) : 1523 - 1534
  • [22] RC Beam–Column Connections Retrofitted by Steel Prop: Experimental and Analytical Studies
    Ali Kheyroddin
    Ebrahim Emami
    Ali Khalili
    International Journal of Civil Engineering, 2020, 18 : 501 - 518
  • [23] Experimental and numerical analysis of assembled steel beam to CFDST column joint
    Fan, Junchao
    Zhao, Junhai
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 218
  • [24] Experimental study on stainless steel blind bolted T-stub to square hollow section connections
    Li, Ying-Lei
    Zhao, Xiao-Ling
    THIN-WALLED STRUCTURES, 2021, 167
  • [25] Experimental Study and Analysis on Rotational Behavior of Bamboo Scrimber Beam-to-Column Bolted Connections
    Leng, Yubing
    Wang, Zhuolin
    Xu, Ming
    JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (09)
  • [26] I-beam to square hollow column blind bolted moment connection: Experimental and numerical study
    Tahir, Mahmood Md.
    Mohammadhosseini, Hossein
    Ngian, Shek Poi
    Effendi, Mahmud Kori
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 148 : 383 - 398
  • [27] Elasto plastic behavior of steel beam to square concrete filled steel tube (CFT) column connections
    Fukumoto, T
    Morita, K
    COMPOSITE AND HYBRID STRUCTURES, VOLS 1 AND 2, 2000, : 565 - 572
  • [28] Experimental study on demountable and reusable steel beam-to-column joints with bolted-pinned connections
    Yang, Lu
    Peng, Lei
    Ban, Huiyong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 214
  • [29] EXPERIMENTAL STUDY OF RESILIENT PREFABRICATED STEEL FRAME WITH ALL-BOLTED BEAM-TO-COLUMN CONNECTIONS
    Zhang, Ai-Lin
    Shangguan, Guang-Hao
    Zhang, Yan-Xia
    Wang, Qing-Bo
    Cai, Wen-Chao
    ADVANCED STEEL CONSTRUCTION, 2020, 16 (03): : 255 - 271
  • [30] Rotational behavior and modeling of bolted glulam beam-to-column connections with slotted-in steel plate
    Sun, Xiaoluan
    Qu, Yiheng
    Liu, Weiqing
    Lu, Weidong
    Yuan, Shenglin
    ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (09) : 1989 - 2000