The performance of biological and tertiary wastewater treatment procedures for rotaviruses A removal

被引:0
|
作者
Chourouk Ibrahim
Salah Hammami
Pierre Pothier
Nesserine Khelifi
Abdennaceur Hassen
机构
[1] Centre of Research and Water Technologies (CERTE),Laboratory of Treatment and Valorization of Water Rejects (LTVRH)
[2] University of Tunis El Manar,Faculty of Mathematical, Physical and Natural Sciences of Tunis
[3] University of Manouba,National School of Veterinary Medicine at Sidi
[4] University Hospital of Dijon,Thabet, IRESA
关键词
Sewage; Biological treatment; Tertiary treatment; Performance; Removal; Viral gastroenteritis;
D O I
暂无
中图分类号
学科分类号
摘要
Enteric viruses, generally found in sewage, are recognized as the main cause of waterborne and foodborne public health outbreaks. Among leading enteric viruses, the Rotavirus A (RVA) detection in wastewater appeared to be a novel approach to monitor the emergence of these viruses in some countries where the viral gastroenteritis surveillance is almost absent such as in Tunisia. The RVA detection and quantification in an industrial sewage purification plant of Charguia I (Tunis, Tunisia) were achieved to evaluate the performance of activated sludge procedures coupled to a macrofiltration monolamp ultraviolet irradiation type C (UV-C254) disinfection reactor. This UV-C254 system was preceded by a fiberglass cartridge filter system with an average porosity of 45 μm to clarify the water and thus increase its UV transmittance. A total of 140 composite sewage samples was collected from this line of treatment and analyzed for RVA detection. The detection and the viral load quantification of RVA were performed using real-time reverse transcription polymerase chain reaction (RT-PCR). The virological results showed in general that RVA were detected at high frequency of 98% (137/140). In fact, the RVA detection rates at the exit of the two studied wastewater treatment were about 100% at the exit of the activated sludge procedure. It means that all wastewater sampled at this last step of treatment was positive for RVA detection. On the other hand, 92.5% of the wastewater samples taken at the exit of the monolamp UV-C254 reactor were positive for the RVA. However, the RVA quantification results expressed as viral load showed a significant reduction in the means of RVA viral loads at the exit of the biological activated sludge procedure and the tertiary UV-C254 treatment, showing in general an improved treated wastewater virological quality. Therefore, the RVA load removal rates recorded at the two successive stages of treatment, the activated sludge and the UV-C254 treatment, were around 85% and 73%, respectively, as compared to the one with 100% registered for the raw wastewater. In addition, good physical-chemical and bacteriological qualities of the treated sewage were found at the exit of the two considered wastewater treatment procedures. The present investigation represents the first Tunisian environmental report showing the good effectiveness and performance of the biological and the tertiary treatments for RVA removal. Therefore, an improved and an optimized tertiary disinfection treatment was needed since it could be a good means for getting better viral water quality and for minimizing the transmission and dissemination of human infectious viral diseases.
引用
下载
收藏
页码:5718 / 5729
页数:11
相关论文
共 50 条
  • [21] Nanomaterial Removal and Transformation During Biological Wastewater Treatment
    Westerhoff, Paul K.
    Kiser, Ayla
    Hristovski, Kiril
    ENVIRONMENTAL ENGINEERING SCIENCE, 2013, 30 (03) : 109 - 117
  • [22] Biological nitrogen removal at small wastewater treatment facilities
    Pare, Mark K.
    Journal of New England Water Environment Association, 1994, 28 (02): : 154 - 163
  • [23] Thermophilic biological nitrogen removal in industrial wastewater treatment
    Lopez-Vazquez, C. M.
    Kubare, M.
    Saroj, D. P.
    Chikamba, C.
    Schwarz, J.
    Daims, H.
    Brdjanovic, D.
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2014, 98 (02) : 945 - 956
  • [24] Assays for the tertiary biological treatment of wastewater using autotrophic biomass
    Espigares, M
    Lopez, JAP
    FernandezCrehuet, M
    Galvez, R
    ENVIRONMENTAL TOXICOLOGY AND WATER QUALITY, 1996, 11 (01): : 37 - 44
  • [25] Biological wastewater treatment followed by physicochemical treatment for the removal of fluorinated surfactants
    Schroeder, H. Fr
    Jose, H. J.
    Gebhardt, W.
    Moreira, R. F. P. M.
    Pinnekamp, J.
    WATER SCIENCE AND TECHNOLOGY, 2010, 61 (12) : 3208 - 3215
  • [26] Removal of micropollutants during tertiary wastewater treatment by biofiltration: Role of nitrifiers and removal mechanisms
    Rattier, M.
    Reungoat, J.
    Keller, J.
    Gernjak, W.
    WATER RESEARCH, 2014, 54 : 89 - 99
  • [27] Removal efficiency of commonly prescribed antibiotics via tertiary wastewater treatment
    Kayla D. Burch
    Bangshuai Han
    John Pichtel
    Tykhon Zubkov
    Environmental Science and Pollution Research, 2019, 26 : 6301 - 6310
  • [28] Particle removal in different filtration systems for tertiary wastewater treatment - A comparison
    Kobler, D
    Boller, M
    WATER SCIENCE AND TECHNOLOGY, 1997, 36 (04) : 259 - 267
  • [29] Removal efficiency of commonly prescribed antibiotics via tertiary wastewater treatment
    Burch, Kayla D.
    Han, Bangshuai
    Pichtel, John
    Zubkov, Tykhon
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2019, 26 (07) : 6301 - 6310
  • [30] Tracing the limits of organic micropollutant removal in biological wastewater treatment
    Falas, Per
    Wick, Arne
    Castronovo, Sandro
    Habermacher, Jonathan
    Ternes, Thomas A.
    Joss, Adriano
    WATER RESEARCH, 2016, 95 : 240 - 249