Single-point parallel disk correction for asymptotically nonlinear oscillatory shear

被引:0
|
作者
N. Ashwin Bharadwaj
Randy H. Ewoldt
机构
[1] University of Illinois at Urbana-Champaign,Department of Mechanical Science and Engineering
来源
Rheologica Acta | 2015年 / 54卷
关键词
Parallel disk rheometry; Single point correction; Asymptotically nonlinear rheology; Large amplitude oscillatory shear; Uncertainty propagation in MAOS; MAOS;
D O I
暂无
中图分类号
学科分类号
摘要
We derive exact single-point corrections for parallel disk measurements of all four asymptotically nonlinear measures under strain-controlled oscillatory shear. In this regime, sometimes called medium-amplitude oscillatory shear (MAOS), the derivatives appearing in the general stress correction are constant over the range of interest. This enables an exact single-point correction of all four shear stress components and material functions in the asymptotically nonlinear regime. This greatly simplifies the data processing and allows convenient measurements of true nonlinear material functions with parallel disk geometries. We use a strain amplitude expansion for the stress response, introducing a general non-integer strain amplitude scaling for the leading order nonlinearity, σ ∼ γα, where typically α = 3 has been assumed in the past. The stress corrections are a multiplicative amplification by a factor fα=α+34\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$f\left (\alpha \right )=\frac {\alpha +3}{4}$\end{document}, shown for the first time for all four asymptotically nonlinear coefficients. Experimental measurements are presented for the four asymptotically nonlinear signals on an entangled polymer melt of cis-1,4-polyisoprene, using both parallel disk and cone fixtures. The polymer melt follows a cubic (α = 3) strain amplitude scaling in the MAOS regime. The theoretical corrections indicate a 50 % amplification of the apparent signals measured with the parallel disk fixture. The corrected (amplified) signals match the measurements with the cone.
引用
收藏
页码:223 / 233
页数:10
相关论文
共 27 条
  • [21] Two-directional toolpath correction in single-point incremental forming using model predictive control
    Lu, Haibo
    Kearney, Michael
    Liu, Sheng
    Daniel, William J. T.
    Meehan, Paul A.
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2017, 91 (1-4): : 91 - 106
  • [22] Two-directional toolpath correction in single-point incremental forming using model predictive control
    Haibo Lu
    Michael Kearney
    Sheng Liu
    William J.T. Daniel
    Paul A. Meehan
    The International Journal of Advanced Manufacturing Technology, 2017, 91 : 91 - 106
  • [23] Single-point blow-up for a degenerate parabolic problem with a nonlinear source of local and nonlocal features
    Chan, CY
    Tian, HY
    APPLIED MATHEMATICS AND COMPUTATION, 2003, 145 (2-3) : 371 - 390
  • [24] T-SPP: Improving GNSS Single-Point Positioning Performance Using Transformer-Based Correction
    Wu, Fan
    Wei, Liangrui
    Luo, Haiyong
    Zhao, Fang
    Ma, Xin
    Ning, Bokun
    INTERNATIONAL JOURNAL OF INTELLIGENT SYSTEMS, 2024, 2024
  • [25] Single-point Residual Correction Method for Articulated Arm Coordinate Measuring Machine Based on Pose Configuration's polynomial model
    Xu, You
    Gao, Qun
    Yu, Limin
    Yang, Yong
    2017 IEEE 7TH ANNUAL INTERNATIONAL CONFERENCE ON CYBER TECHNOLOGY IN AUTOMATION, CONTROL, AND INTELLIGENT SYSTEMS (CYBER), 2017, : 189 - 193
  • [26] The far downstream evolution of the high-Reynolds-number axisymmetric wake behind a disk. Part 1. Single-point statistics
    Johansson, PBV
    George, WK
    JOURNAL OF FLUID MECHANICS, 2006, 555 : 363 - 385
  • [27] Centrifugal multiplexing fixed-volume dispenser on a plastic lab-on-a-disk for parallel biochemical single-end-point assays
    La, Moonwoo
    Park, Sang Min
    Kim, Dong Sung
    BIOMICROFLUIDICS, 2015, 9 (01):