Prognostic value of real-time three-dimensional echocardiography compared to two-dimensional echocardiography in patients with systolic heart failure

被引:0
|
作者
Frederico J. N. Mancuso
Valdir A. Moises
Dirceu R. Almeida
Dalva Poyares
Luciana J. Storti
Flavio S. Brito
Sergio Tufik
Angelo A. V. de Paola
Antonio C. C. Carvalho
Orlando Campos
机构
[1] Universidade Federal de São Paulo/Escola Paulista de Medicina (UNIFESP/EPM),Cardiology Department
[2] Universidade Federal de São Paulo/Escola Paulista de Medicina (UNIFESP/EPM),Sleep Institute
关键词
Heart failure; Real-time three-dimensional echocardiography; Prognosis;
D O I
暂无
中图分类号
学科分类号
摘要
Heart failure (HF) is associated with morbidity and mortality. Real-time three-dimensional echocardiography (RT3DE) may offer additional prognostic data in patients with HF. The study aimed to evaluate the prognostic value of real-time three-dimensional echocardiography (RT3DE). This is a prospective study that included 89 patients with HF and left ventricular ejection fraction (LVEF) < 0.50 who were followed for 48 months. Left atrium and ventricular volumes and functions were evaluated by RT3DE. TDI and two-dimensional echocardiography parameters were also obtained. The endpoint was a composite of death, heart transplantation and hospitalization for acute decompensated HF. The mean age was 55 ± 11 years, and the LVEF was 0.32 ± 0.10. The composite endpoint occurred in 49 patients (18 deaths, 30 hospitalizations, one heart transplant). Patients with outcomes had greater left atrial volume (40 ± 16 vs. 32 ± 12 mL/m2; p < 0.01) and right ventricle diameter (41 ± 9 vs. 37 ± 8 mm, p = 0.01), worse total emptying fraction of the left atrium (36 ± 13% vs. 41 ± 11%; p = 0.03), LVEF (0.30 ± 0.09 vs. 0.34 ± 0.11; p = 0.02), right ventricle fractional area change (34.8 ± 12.1% vs. 39.2 ± 11.3%; p = 0.04), and greater E/e′ ratio (19 ± 9 vs. 16 ± 8; p = 0.04) and systolic pulmonary artery pressure (SPAP) (50 ± 15 vs. 36 ± 11 mmHg; p < 0.01). In multivariate analysis, LVEF (OR 4.6; CI 95% 1.2–17.6; p < 0.01) and SPAP (OR 12.5; CI 95% 1.8–86.9; p < 0.01) were independent predictors of patient outcomes. LVEF and the SPAP were independent predictors of outcomes in patients with HF.
引用
收藏
页码:553 / 560
页数:7
相关论文
共 50 条
  • [31] Left ventricular systolic dyssynchrony is common in heart failure patients with narrow QRS complexes: a real-time three-dimensional echocardiography study
    Ma, C. Y.
    Zhang, Q.
    Chan, Y. S.
    Fung, J. W. H.
    Yip, G. W. K.
    Fang, F.
    Li, C. M.
    Xie, J. M.
    Liang, Y. J.
    Yu, C. M.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 125 : S46 - S47
  • [32] Prognostic value of biventricular remodeling by real-time three-dimensional echocardiography in patients with idiopathic pulmonary arterial hypertension
    Yao, H. H.
    Shu, X. H.
    Kong, D. H.
    Pan, C. Z.
    Dong, L. L.
    Zhou, D. X.
    Ge, J. B.
    EUROPEAN HEART JOURNAL, 2016, 37 : 467 - 467
  • [33] Real Time Three-Dimensional Echocardiography
    Ahmad, Masood
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (01): : 64 - 65
  • [34] Real-time three-dimensional echocardiography for left atrial volume assessment in Thoroughbred racehorses: Observer variability and comparison with two-dimensional echocardiography
    Worsman, Francesca C. F.
    Miller, Zack J.
    Shaw, Darren J.
    Blissitt, Karen J.
    Keen, John A.
    EQUINE VETERINARY JOURNAL, 2022, 54 (01) : 176 - 190
  • [35] Detection of left ventricular systolic dysfunction and dyssynchrony in patients with single or dual chamber pacemaker using two-dimensional and real-time three-dimensional echocardiography
    Elnaggar, Heba M.
    Aboul-Fadl, Rawad T.
    Mohammad, Hamdy Shams-Eddin
    Fouad, Doaa A.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2020, 22 (0K) : K6 - K6
  • [36] True mitral annulus diameter is underestimated by two-dimensional echocardiography as evidenced by real-time three-dimensional echocardiography and magnetic resonance imaging
    Anwar, Ashraf M.
    Soliman, Osama I. I.
    ten Cate, Folkert J.
    Nemes, Attila
    McGhie, Jackie S.
    Krenning, Boudewijn J.
    van Geuns, Robert-Jan
    Galema, Tjebbe W.
    Geleijnse, Marcel L.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2007, 23 (05): : 541 - 547
  • [37] True mitral annulus diameter is underestimated by two-dimensional echocardiography as evidenced by real-time three-dimensional echocardiography and magnetic resonance imaging
    Ashraf M. Anwar
    Osama I. I. Soliman
    Folkert J. ten Cate
    Attila Nemes
    Jackie S. McGhie
    Boudewijn J. Krenning
    Robert-Jan van Geuns
    Tjebbe W. Galema
    Marcel L. Geleijnse
    The International Journal of Cardiovascular Imaging, 2007, 23 : 541 - 547
  • [38] En Face View of Atrial Septal Defect by Two-Dimensional Transthoracic Echocardiography: Comparison to Real-Time Three-Dimensional Transesophageal Echocardiography
    Huang, Xinsheng
    Shen, Junjun
    Huang, Yigao
    Zheng, Zhichao
    Fei, Hongwen
    Hou, Yueshuang
    Xu, Yan
    Huang, Tao
    Huang, Wenhui
    Zhang, Caojin
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (07) : 714 - 721
  • [39] Overestimation of Left Ventricular Mass and Misclassification of Ventricular Geometry in Heart Failure Patients by Two-Dimensional Echocardiography in Comparison with Three-Dimensional Echocardiography
    Abramov, Dmitry
    Helmke, Stephen
    Rumbarger, Lyna El-Khoury
    King, Donald L.
    Maurer, Mathew S.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2010, 27 (03): : 223 - 229
  • [40] Comparison of Real-Time Three-Dimensional Transesophageal Echocardiography to Two-Dimensional Transesophageal Echocardiography for Quantification of Mitral Valve Prolapse in Patients With Severe Mitral Regurgitation
    Izumo, Masaki
    Shiota, Maiko
    Kar, Saibal
    Gurudevan, Swaminatha V.
    Tolstrup, Kirsten
    Siegel, Robert J.
    Shiota, Takahiro
    AMERICAN JOURNAL OF CARDIOLOGY, 2013, 111 (04): : 588 - 594