Application of Time-Domain Reflectometry for Measurement of Moisture Profiles in a Drying Experiment

被引:0
|
作者
Z. Pavlík
J. Mihulka
L. Fiala
R. Černý
机构
[1] Czech Technical University in Prague,Department of Materials Engineering and Chemistry, Faculty of Civil Engineering
来源
关键词
Calcium silicate; Drying experiment; Moisture content; TDR method;
D O I
暂无
中图分类号
学科分类号
摘要
The time-domain reflectometry (TDR) method is used for the measurement of moisture profiles in calcium silicate during a drying experiment. The specimens are saturated at first by water, and their lateral sides and one of the face sides are water- and vapor-proof insulated to ensure one-dimensional (1-D) water transport. Then, the drying process is started in an environment with a relative humidity of 20%. Moisture profiles are measured at specified time intervals using the TDR method. The experiment is stopped when the moisture content along the whole length of the sample is lower than the maximum hygroscopic moisture content. The obtained results can be used for the determination of moisture diffusivity in the drying phase of moisture transport.
引用
收藏
页码:1661 / 1673
页数:12
相关论文
共 50 条
  • [21] Rapid measurement of soil matric suction by time-domain reflectometry
    He, L
    Leong, EC
    Rahardjo, H
    FIELD MEASUREMENTS OF GEOMECHANICS, 1999, : 543 - 548
  • [22] Measurement of the electromagnetic constants of concrete materials by time-domain reflectometry
    Xu, QW
    Shi, LH
    Gao, C
    2002 3RD INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, 2002, : 230 - 233
  • [23] Dielectric constant measurement of zeolite powders by time-domain reflectometry
    Sun, Minwei
    Maichen, Wolfgang
    Pophale, Ramdas
    Liu, Yan
    Cai, Rui
    Lew, Christopher M.
    Hunt, Heather
    Deem, Michael W.
    Davis, Mark E.
    Yan, Yushan
    MICROPOROUS AND MESOPOROUS MATERIALS, 2009, 123 (1-3) : 10 - 14
  • [24] APPLICATION OF METHOD OF TIME-DOMAIN REFLECTOMETRY TO STUDY OF ELECTRODE PROCESSES
    PAYNE, R
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1968, 19 (1-2): : 1 - &
  • [25] A TIME-DOMAIN REFLECTOMETRY USING ENVELOPE EXTRACTION AND ITS APPLICATION TO MEASUREMENT OF STRIPLINE RESONATOR CHARACTERISTICS
    OMORI, T
    YASHIRO, K
    OHKAWA, S
    IEICE TRANSACTIONS ON ELECTRONICS, 1994, E77C (06) : 908 - 912
  • [26] Laboratory calibration and in situ measurements of moisture by using time-domain reflectometry probes
    Diefenderfer, BK
    Al-Qadi, IL
    Loulizi, A
    PAVEMENT MANAGEMENT AND MONITORING: PAVEMENT DESIGN, MANAGEMENT, AND PERFORMANCE, 2000, (1699): : 142 - 150
  • [27] Is the Time-Domain Reflectometry (TDR) Technique Suitable for Moisture Content Measurement in Low-Porosity Building Materials?
    Freitas, Teresa Stingl
    Guimaraes, Ana Sofia
    Roels, Staf
    Peixoto de Freitas, Vasco
    Cataldo, Andrea
    SUSTAINABILITY, 2020, 12 (19)
  • [28] Laboratory calibration and in situ measurements of moisture by using time-domain reflectometry probes
    Transportation Institute, Virginia Polytech. Inst. State Univ., 3500 Transportation Research Drive, Blacksburg, VA 24061, United States
    Transportation Research Record, 2000, (1699) : 142 - 150
  • [29] Determination of moisture content in a deformable soil using time-domain reflectometry (TDR)
    Kim, DJ
    Choi, SI
    Ryszard, O
    Feyen, J
    Kim, HS
    EUROPEAN JOURNAL OF SOIL SCIENCE, 2000, 51 (01) : 119 - 127
  • [30] METHODOLOGY OF MOISTURE MEASUREMENT IN POROUS MATERIALS USING TIME DOMAIN REFLECTOMETRY
    Suchorab, Zbigniew
    Widomski, Marcin K.
    Lagod, Grzegorz
    Barnat-Hunek, Danuta
    Smarzewski, Piotr
    CHEMISTRY-DIDACTICS-ECOLOGY-METROLOGY, 2014, 19 (1-2) : 97 - 107