Flux calculation in LSNAA using an 241Am-Be source

被引:0
|
作者
R. Khelifi
P. Bode
A. Amokrane
机构
[1] Université Saad DAHLAB,Department de Physique
[2] Interfaculty Reactor Institute,undefined
[3] Faculté de Physique,undefined
关键词
Neutron Source; Flux Distribution; Neutron Spectrum; Thermal Flux; Flux Calculation;
D O I
暂无
中图分类号
学科分类号
摘要
The CITATION code based on neutron diffusion theory is used for flux calculation inside voluminous sample in prompt gamma activation analysis with an isotopic neutron source (241Am-Be). The code used the specific parameters related to energy spectrum source, irradiation system materials (shielding, reflector, etc.), geometry and elemental composition of the sample. The flux distribution (thermal and fast) was calculated on three-dimensional geometry for the system: source, air, and polyethylene and water cylindrical sample of 125 liters. The thermal flux was calculated in series of points inside the sample, and agreed with the results obtained by measurements with good statistical uncertainty. The maximum thermal flux was measured at distance of 4.1 cm and calculated at 4.3 cm by the CITATION code. Beyond a depth of 7.2 cm, the ratio of thermal flux to fast flux increases up to twice and allows us the optimization of the detection system in the scope of in-situ PGNAA.
引用
收藏
页码:639 / 642
页数:3
相关论文
共 50 条
  • [21] Prompt gamma neutron activation analysis of boron with a 241Am-Be neutron source
    Ş. Turhan
    H. Yücel
    A. Demirbaş
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 262 (3) : 661 - 664
  • [22] Parameters fitting of the neutron field formed by 241Am-Be neutron source in the coal
    Yang, Yi-Gang
    Li, Yuan-Jing
    Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology, 2003, 23 (03):
  • [23] IMPROVING THE PERFORMANS OF 241Am-Be FOR PGNAA APPLICATIONS USING A PROPER SHIELDING FOR NEUTRON SOURCE AND THE NaI DETECTOR
    Panjeh, Hamed
    Hakimabad, Hashem M.
    Motavalli, Lalle R.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2010, 25 (03): : 205 - 211
  • [24] Neutron shielding design for 241Am-Be neutron source considering different sites to achieve maximum thermal and fast neutron flux using MCNPX code
    Nasrabadi, M. N.
    Baghban, G.
    ANNALS OF NUCLEAR ENERGY, 2013, 59 : 47 - 52
  • [25] Study of neutron spectra emitted by moderated 241Am-Be source for various moderating materials by using simulation technique
    Kumari, N. Sujatha
    Sathian, V.
    Ghodke, S. S.
    Singh, Yashoda
    Mahant, A. K.
    Ganesan, S.
    RADIATION PROTECTION DOSIMETRY, 2012, 150 (01) : 96 - 100
  • [26] MONTE CARLO SIMULATION STUDY ON THE 241Am-Be RADIONUCLIDE SOURCE REFERENCE NEUTRON RADIATION
    Liu, Yixin
    Zhang, Song
    Qian, Yikun
    Huang, Yuchen
    Mao, Benjiang
    Feng, Peng
    Chen, Zhiqiang
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2020, 35 (04): : 283 - 293
  • [27] Compact shielding design for 740 GBq 241Am-Be neutron source transport container
    Basu, Pew
    Sarangapani, R.
    Venkatraman, B.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 170
  • [28] Determination of the Optimal Position of Sample for Neutron Activation Analysis in 241Am-Be Neutron Source Facility
    Tahanipour, Nasser
    Tajik, Mojtaba
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY TRANSACTION A-SCIENCE, 2022, 46 (03): : 1011 - 1017
  • [29] Monte Carlo study of a flexible device for in situ PGNAA using 241Am-Be source: application to total chlorine determination
    Khelifi, R.
    Bode, P.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 309 (01) : 189 - 193
  • [30] Verification of a fusion neutron diagnostic Bonner sphere spectrometer on measurement of a 241Am-Be neutron source
    Cao, Jing
    Jiang, Chun-Yu
    Yang, Qing-Wei
    Yin, Ze-Jie
    NUCLEAR SCIENCE AND TECHNIQUES, 2016, 27 (06)