Comparison of dual-source CT angiography and MR angiography in preoperative evaluation of intra- and extracranial vessels: a pilot study

被引:0
|
作者
Georg Mühlenbruch
Marco Das
Gottfried Mommertz
Meike Schaaf
Stefan Langer
Andreas Horst Mahnken
Joachim Ernst Wildberger
A. Thron
Rolf W. Günther
Timo Krings
机构
[1] RWTH Aachen University,Department of Diagnostic and Interventional Radiology
[2] RWTH Aachen University,Department of Vascular Surgery
[3] University Hospital Maastricht,Department of Radiology
[4] RWTH Aachen University,Department of Neuroradiology
来源
European Radiology | 2010年 / 20卷
关键词
Carotid artery; CT angiography; MR angiography; Carotid stenosis; Image quality;
D O I
暂无
中图分类号
学科分类号
摘要
Besides the assessment of carotid artery stenosis, evaluation of the vascular anatomy and lesions within both the extra- and intracranial arteries is crucial for proper clinical evaluation, treatment choice and planning. The purpose of our study was to evaluate the potential of dual-source CTA and 3T-MRA. In 16 symptomatic CAS patients, contrast-enhanced DSCT and 3T-MRA examinations were performed. For DSCT a dual-energy protocol with a 64 × 0.6-mm collimation was applied. In 3T-MRA intracranial high-resolution unenhanced TOF and extracranial contrast-enhanced MRA were performed. All examinations were analyzed for relevant morphologic and pathologic features or anomalies, and a total of 624 vessel segments were scored. All examinations were of diagnostic image quality with good to excellent vessel visibility. Almost all intracranial arteries were significantly better visualized by MRA compared to CTA (five of six vessels, p < 0.05). DSCT however allowed for further morphological carotid stenosis description, especially with respect to calcification. Although MRA proved to be superior in visualization of smaller intracranial arteries, all pre-interventionally relevant information could be perceived from DSCT. DSCT and MRA may both be regarded as a reliable, fast, pre-interventional imaging investigation in patients with carotid artery stenosis.
引用
收藏
页码:469 / 476
页数:7
相关论文
共 50 条
  • [21] Low dose dual-source CT angiography of the thoracic aorta
    Farrelly, Cormac
    Davarpanah, Amir
    Keeling, Aoife N.
    Sheehan, John
    Ragin, Ann
    Yaghmai, Vahid
    Carr, James C.
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07): : 1025 - 1034
  • [22] Is dual-source CT coronary angiography ready for the real world?
    Cademartiri, Filippo
    Maffei, Erica
    Mollet, Nico R.
    [J]. EUROPEAN HEART JOURNAL, 2008, 29 (06) : 701 - 703
  • [23] Low dose dual-source CT angiography of the thoracic aorta
    Cormac Farrelly
    Amir Davarpanah
    Aoife N. Keeling
    John Sheehan
    Ann Ragin
    Vahid Yaghmai
    James C. Carr
    [J]. The International Journal of Cardiovascular Imaging, 2011, 27 : 1025 - 1034
  • [24] Dual-Source Versus Single-Source Cardiac CT Angiography: Comparison of Diagnostic Image Quality
    Donnino, Robert
    Jacobs, Jill E.
    Doshi, Jay V.
    Hecht, Elizabeth M.
    Kim, Danny C.
    Babb, James S.
    Srichai, Monvadi B.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (04) : 1051 - 1056
  • [25] Emergent Computed Tomography Angiography of Intra- and Extracranial Vessels; Ordering Patterns and Yield at a Single Institution
    Hextrum, Shannon
    Ortiz, Jorge
    Hornik, Jonatan
    Rosenblum, Jordan
    Bar, Barak
    [J]. ANNALS OF NEUROLOGY, 2017, 82 : S99 - S100
  • [26] Comparison of dual-source computed tomography (CT) dual-energy angiography with conventional 3D imaging towards caudomedial vessels
    Li, Daowei
    Liu, Na
    Ma, Qiang
    He, Dan
    [J]. BIOMEDICAL RESEARCH-INDIA, 2017, 28 (12): : 5445 - 5449
  • [27] 3-T MR Angiography for Comprehensive Renal Evaluation of Living Renal Donors: Pilot Study With CT Angiography Comparison
    Gulati, M.
    Raman, S.
    Gomez, A.
    Margolis, D.
    Bliss, S.
    Lu, D.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [28] Detection of coronary artery anomalies by dual-source CT coronary angiography
    Cheng, Z.
    Wang, X.
    Duan, Y.
    Wu, L.
    Wu, D.
    Liang, C.
    Liu, C.
    Xu, Z.
    [J]. CLINICAL RADIOLOGY, 2010, 65 (10) : 815 - 822
  • [29] Diagnostic accuracy of dual-source CT angiography and coronary risk stratification
    Yang, Xia
    Gai, Lu-yue
    Li, Ping
    Chen, Yun-dai
    Li, Tao
    Yang, Li
    [J]. VASCULAR HEALTH AND RISK MANAGEMENT, 2010, 6 : 935 - 941
  • [30] Comparison of diagnostic accuracy of dual-source CT and conventional angiography in detecting congenital heart diseases
    Sedaghat, Fariborz
    Pouraliakbar, Hamidreza
    Motevalli, Marzieh
    Karimi, Mohammad Ali
    Armand, Sandbad
    [J]. POLISH JOURNAL OF RADIOLOGY, 2014, 79 : 164 - 168