Fatigue Performance of Fluidized Bed Heat Treated 319 Alloy Diesel Cylinder Heads

被引:0
|
作者
Sujoy K. Chaudhury
Diran Apelian
Philippe Meyer
Denis Massinon
Julien Morichon
机构
[1] Metal Processing Institute (MPI),Department of Metallurgy
[2] Worcester Polytechnic Institute (WPI),undefined
[3] Montupet S.A,undefined
[4] Indus University,undefined
[5] Aleris,undefined
关键词
Fatigue; Fatigue Life; Fatigue Strength; Stress Amplitude; Solution Heat Treatment;
D O I
暂无
中图分类号
学科分类号
摘要
Effects of various heat treatment tempers on fatigue performance of 319 alloy diesel cylinder heads were investigated. Castings were heat treated to T5, T6, and T7 tempers. Castings were solution heat treated and quenched using fluidized beds and aged using both conventional air convective furnace and fluidized bed for T6 and T7 tempers; while they were aged after casting for T5 temper using conventional furnace. Fatigue tests were performed at 373 K (100 °C) and stress ratio equal to −1. Results show that heat treatment has significant effect on the fatigue behavior of 319 alloy. The fatigue strength of T6 tempered 319 alloy is greater than T5 and T7 treatments. Weibull analysis shows that the Weibull modulus and characteristic fatigue life of castings treated (using conventional forced air circulation electrical resistance furnace) to T6 and T7 tempers are greater than T5 temper. This implies that castings treated to T6 and T7 tempers have greater reliability vis-à-vis T5 temper. Fractographic analyses reveal three distinct regions. These are: (I) crack initiation region from the surface, (II) crack propagation region, and (III) catastrophic or monotonic failure region. The relative size of the crack propagation region in T6 and T7 treated samples is greater than T5 treated samples. In general, the monotonic failure region shows typical dimple morphology, which implies significant plastic deformation prior to failure. Dimples on the fractured surface of T5 treated alloy are relatively more faceted than those treated to T6 and T7 tempers. This implies that the 319 alloy treated to T6 and T7 tempers underwent higher degree of plasticity prior to failure than that in the T5 condition.
引用
收藏
页码:3015 / 3027
页数:12
相关论文
共 50 条
  • [21] Heat transfer between FCC catalyst and an electrically heated horizontal cylinder in a circulating fluidized bed
    Courbariaux, Y
    Pugsley, T
    Couturier, M
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1999, 77 (02): : 213 - 222
  • [22] INVESTIGATION OF LOCAL HEAT-TRANSFER BETWEEN A FIXED HORIZONTAL CYLINDER AND A FLUIDIZED-BED
    BERG, BV
    BASKAKOV, AP
    INTERNATIONAL CHEMICAL ENGINEERING, 1974, 14 (03): : 440 - 443
  • [23] Cast Aluminum Alloy for thermo-mechanically highly loaded Diesel and Petrol Engine-Cylinder Heads
    Stauder, Bernhard
    Feikus, Franz-Josef
    Oberschelp, Christian
    VENTILTRIEB UND ZYLINDERKOPF 2017, 2017, 2291 : 129 - 140
  • [24] Investigation on Heat Transfer Performance of External Heat Exchanger for Circulating Fluidized Bed Boiler
    Zhang, Dalong
    Yang, Dinghua
    Yang, Gensheng
    Li, Zhong
    Lv, Junfu
    THERMAL, POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 732-733 : 11 - +
  • [25] Performance of circulating fluidized bed boiler with compact external heat exchanger
    Li, W
    Fang, JH
    Yang, ZL
    Wang, HG
    Yan, GZ
    Hua, Z
    Chen, HZ
    Liu, S
    ENERGY CONVERSION AND APPLICATION, VOL I AND II, 2001, : 695 - 698
  • [26] Assessment of heat transfer performance in a swirling fluidized bed with binary mixture
    Wu, Qiang
    Wang, Shuai
    Zhang, Kai
    He, Yurong
    APPLIED THERMAL ENGINEERING, 2021, 194
  • [27] Mechanical performance of heat treated 319 alloys as a function of alloying and aging parameters
    Alkahtani, Saleh
    MATERIALS & DESIGN, 2012, 41 : 358 - 369
  • [28] Advance in fluidized bed coating: An experimental investigation on a performance polymer coating alloy
    Barletta, M.
    Simone, G.
    Tagliaferri, V.
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2006, 178 (1-3) : 170 - 180
  • [29] HEAT-TRANSFER BETWEEN A HORIZONTAL CYLINDER AND A MIXED PARTICLE-SIZE FLUIDIZED-BED
    PITTS, DR
    FIGLIOLA, RS
    HAMLYN, KM
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1982, 104 (03): : 563 - 565
  • [30] LOCAL HEAT-TRANSFER COEFFICIENTS OF A HORIZONTAL CYLINDER IN A GAS-SOLID FLUIDIZED-BED
    MAGILIOTOU, MC
    ASSAEL, MJ
    NYCHAS, SG
    CHEMICAL ENGINEERING COMMUNICATIONS, 1986, 40 (1-6) : 335 - 344