Development of a simplified method for the simultaneous determination of retinol, α-tocopherol, and β-carotene in serum by liquid chromatography–tandem mass spectrometry with atmospheric pressure chemical ionization

被引:0
|
作者
Roberta Andreoli
Paola Manini
Diana Poli
Enrico Bergamaschi
Antonio Mutti
Wilfried M. A. Niessen
机构
[1] University of Parma,ISPESL Research Center
[2] University of Parma,Laboratory of Industrial Toxicology, Department of Clinical Medicine, Nephrology and Health Sciences
[3] hyphen MassSpec Consultancy,undefined
来源
关键词
Retinol; α-Tocopherol; β-Carotene; Serum; LC-APCI-MS-MS; Ozone;
D O I
暂无
中图分类号
学科分类号
摘要
A new and simple method for the determination of fat-soluble vitamins (retinol, α-tocopherol, and β-carotene) in human serum was developed and validated by using liquid chromatography–tandem mass spectrometry with atmospheric pressure chemical ionization (LC-APCI-MS-MS). Different solvent mixtures were tested to obtain deproteinization and extraction of the analytes from the matrix. As a result, a volume of 240 μL of a 1:1 (v/v) ethanol/ethyl acetate mixture added to 60 μL of serum was found to be suitable for both protein precipitation and antioxidants solubilization, giving the best recovery for all three analytes. Deproteinized samples (20 μL) were injected after dilution, without the need for concentration or evaporation to dryness and reconstruction of the sample. Vitamins were separated on a C-8 column using a 95:5 (v/v) methanol/dichloromethane mixture and ionized in the positive-ion mode; detection was performed in the selected-reaction monitoring mode. Linearity of the LC-APCI-MS-MS method was established over 5 orders of magnitude for retinol and α-tocopherol, whereas in the case of β-carotene it was limited to 4 orders. Lower limits of quantitation were 1.7, 2.3, and 4.1 nM for retinol, α-tocopherol, and β-carotene, respectively. Serum concentrations of retinol, α-tocopherol, and α+β-carotene determined in a group of healthy volunteers were 2.48, 38.07, and 0.50 μM, respectively, in samples collected in winter (n=122) and 2.69, 45.88, and 0.90 μM during summer (n=66).
引用
收藏
页码:987 / 994
页数:7
相关论文
共 50 条
  • [31] High performance liquid chromatography atmospheric pressure chemical ionization mass spectrometry for the determination of carotenoids
    Clarke, PA
    Barnes, KA
    Startin, JR
    Ibe, FI
    Shepherd, MJ
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1996, 10 (14) : 1781 - 1785
  • [32] Determination of α-tocopherol in infant foods by liquid chromatography combined with atmospheric pressure chemical ionisation mass spectrometry
    Kalman, A
    Mujahid, C
    Mottier, P
    Heudi, O
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (07) : 723 - 727
  • [33] Development of a liquid chromatography tandem mass spectrometry method for the simultaneous determination of zearalenone, deoxynivalenol and their metabolites in pig serum
    Brezina, Ulrike
    Valenta, Hana
    Rempe, Inga
    Kersten, Susanne
    Humpf, Hans-Ulrich
    Daenicke, Sven
    MYCOTOXIN RESEARCH, 2014, 30 (03) : 171 - 186
  • [34] Development of a liquid chromatography tandem mass spectrometry method for the simultaneous determination of zearalenone, deoxynivalenol and their metabolites in pig serum
    Ulrike Brezina
    Hana Valenta
    Inga Rempe
    Susanne Kersten
    Hans-Ulrich Humpf
    Sven Dänicke
    Mycotoxin Research, 2014, 30 : 171 - 186
  • [35] Determination of astragalosides in the roots of Astragalus spp. using liquid chromatography tandem atmospheric pressure chemical ionization mass spectrometry
    Xu, Qing
    Ma, Xiaoqiong
    Liang, Xinmiao
    PHYTOCHEMICAL ANALYSIS, 2007, 18 (05) : 419 - 427
  • [36] Quantitative determination of dexamethasone in bovine milk by liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry
    Cherlet, M
    De Baere, S
    De Backer, P
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (01): : 57 - 65
  • [37] Determination of nicotine and cotinine in human plasma by liquid chromatography tandem mass spectrometry with atmospheric-pressure chemical ionization interface
    Xu, AS
    Peng, LL
    Havel, JA
    Petersen, ME
    Fiene, JA
    Hulse, JD
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 682 (02): : 249 - 257
  • [38] Determination of Chlorantraniliprole Residues in Crops by Liquid Chromatography Coupled with Atmospheric Pressure Chemical Ionization Mass Spectrometry/Mass Spectrometry
    Grant, Joann
    Rodgers, Carol A.
    Chickering, Clark D.
    Hill, Sidney J.
    Stry, James J.
    JOURNAL OF AOAC INTERNATIONAL, 2010, 93 (04) : 1293 - 1301
  • [39] Simultaneous quantitative determination method for sphingolipid metabolites by liquid chromatography/ionspray ionization tandem mass spectrometry
    Mano, N
    Oda, Y
    Yamada, K
    Asakawa, N
    Katayama, K
    ANALYTICAL BIOCHEMISTRY, 1997, 244 (02) : 291 - 300
  • [40] SIMULTANEOUS DETERMINATION OF TENIDAP AND ITS STABLE ISOTOPE ANALOG IN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ATMOSPHERIC-PRESSURE CHEMICAL IONIZATION TANDEM MASS-SPECTROMETRY
    AVERY, MJ
    MITCHELL, DY
    FALKNER, FC
    FOUDA, HG
    BIOLOGICAL MASS SPECTROMETRY, 1992, 21 (07) : 353 - 357