Assessing diabetic retinopathy using two-field digital photography and the influence of JPEG-compression

被引:1
|
作者
Catharina Stellingwerf
Peter Hardus
Johanna Hooymans
机构
[1] University Hospital of Groningen,Department of Ophthalmology
来源
Documenta Ophthalmologica | 2004年 / 108卷
关键词
Analogue; Compression; Diabetic retinopathy; Digital; Photography;
D O I
暂无
中图分类号
学科分类号
摘要
Objective: To study the effectiveness of two digital 50° photographic fields per eye, stored compressed or integrally, in the grading of diabetic retinopathy, in comparison to 35-mm colour slides. Subjects and methods: Two-field digital non-stereoscopic retinal photographs and two-field 35-mm retinal photographs were made at the same time from patients visiting a diabetic retinopathy outpatient clinic. The digital images were stored integrally (TIFF-file) and in a compressed way (JPEG-file). Two ophthalmologists assessed the photographs in a masked fashion. The results were compared. The sensitivity and specificity for the detection of vision-threatening diabetic retinopathy were calculated, using only the grading of the most affected eye. The differences between the retinopathy gradings of the two kinds of photographs were analysed. Results: The agreement for the grading of DR compared to slides was good, both for the compressed and for the integrally stored images (kappa 0.63–0.68). The sensitivity for the detection of vision-threatening diabetic retinopathy using the JPEG-stored images was 0.72–0.74, specificity 0.93–0.98. The sensitivity for vision-threatening retinopathy detection using the integrally stored images was 0.86–0.92, specificity 0.93. Conclusions: Two-field digital retinal photography is effective in diabetic retinopathy grading and it can replace 35-mm retinal photography. Vision-threatening retinopathy can be detected on the images with reasonable to good sensitivity and specificity. An experienced grader should assess the images. The compression of the digital images seems to have some adverse effect on the detection of diabetic retinopathy.
引用
收藏
页码:203 / 209
页数:6
相关论文
共 48 条
  • [41] Assessment of diabetic retinopathy using two ultra-wide-field fundus imaging systems, the Clarus® and Optos systems
    Hirano, Takao
    Imai, Akira
    Kasamatsu, Hirotsugu
    Kakihara, Shinji
    Toriyama, Yuichi
    Murata, Toshinori
    [J]. BMC OPHTHALMOLOGY, 2018, 18
  • [42] Two novel methods for field measurements of hydrodynamic density of floodplain vegetation using terrestrial laser scanning and digital parallel photography
    Straatsma, M. W.
    Warmink, J. J.
    Middelkoop, H.
    [J]. INTERNATIONAL JOURNAL OF REMOTE SENSING, 2008, 29 (05) : 1595 - 1617
  • [43] Preventing diabetes blindness: Cost effectiveness of a screening programme using digital non-mydriatic fundus photography for diabetic retinopathy in a primary health care setting in South Africa
    Khan, Taskeen
    Bertram, Melanie Y.
    Jina, Ruxana
    Mash, Bob
    Levitt, Naomi
    Hofman, Karen
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 2013, 101 (02) : 170 - 176
  • [44] Comparison of quantitative assessment and efficiency of diabetic retinopathy diagnosis using ETDRS seven-field imaging and two ultra-widefield imaging
    Yuanyuan Xiao
    Zixu Huang
    Qiongqiong Yuan
    Xiaofeng Du
    Zeyu Li
    Xiaodong Nie
    Qianqian Shi
    Handong Dan
    Zongming Song
    [J]. Eye, 2023, 37 : 3558 - 3564
  • [45] Comparison of quantitative assessment and efficiency of diabetic retinopathy diagnosis using ETDRS seven-field imaging and two ultra-widefield imaging
    Xiao, Yuanyuan
    Huang, Zixu
    Yuan, Qiongqiong
    Du, Xiaofeng
    Li, Zeyu
    Nie, Xiaodong
    Shi, Qianqian
    Dan, Handong
    Song, Zongming
    [J]. EYE, 2023, 37 (17) : 3558 - 3564
  • [46] Full-field mapping of internal strain distribution in red sandstone specimen under compression using digital volumetric speckle photography and X-ray computed tomography
    Lingtao Mao
    Jianping Zuo
    Zexun Yuan
    Fu-Pen Chiang
    [J]. Journal of Rock Mechanics and Geotechnical Engineering, 2015, (02) : 136 - 146
  • [47] Full-field mapping of internal strain distribution in red sandstone specimen under compression using digital volumetric speckle photography and X-ray computed tomography
    Mao, Lingtao
    Zuo, Jianping
    Yuan, Zexun
    Chiang, Fu-Pen
    [J]. JOURNAL OF ROCK MECHANICS AND GEOTECHNICAL ENGINEERING, 2015, 7 (02) : 136 - 146
  • [48] Evaluation of 3D deformation field in siltstone with a pre-existing 3D surface flaw under uniaxial compression using X-ray computed tomography and digital volumetric speckle photography
    Mao, Lingtao
    Lei, Yu
    Ding, Leilei
    Wu, Jingcheng
    Li, Liyun
    Yang, Min
    Ju, Yang
    Chiang, Fu-pen
    [J]. MEASUREMENT, 2022, 189