Since their invention, ion-selective microelectrodes have become an indispensable tool for investigations of intracellular ion regulation and transport. While highly selective sensors for all major intracellular monovalent ions have been available for decades, the development of sensors for divalent cations seems to have presented more difficulties. As ion-selective microelectrodes typically have time-constants in the range of 0.5 to several seconds they turned out to be inapt for the investigation of intracellular Ca2+. The development of sensors for Mg2+-selective electrodes has made its most striking progress only over the past few years. While the first Mg2+ sensor, ETH 1117, was barely able to detect physiological Mg2+ concentrations in the presence of other mono- and divalent cations, the newest sensors allow measurements in the micromolar range. When used in macroelectrodes, the most recent developments, ETH 5506 and ETH 5504, have even been reported to do so in the presence of millimolar Ca2+ concentrations. Although there is still room for improvement to make these sensors applicable in microelectrodes, some preliminary data look extremely promising and indicate that a new era for Mg2+-selective microelectrodes is about to start.
引用
收藏
页码:237 / 249
页数:12
相关论文
共 50 条
  • [11] Putative mechanism of Mg2+/Mg2+ exchange and Na+/Mg2+ antiport
    Gunther, T
    MAGNESIUM-BULLETIN, 1996, 18 (01): : 2 - 6
  • [12] MECHANISMS AND REGULATION OF MG2+ EFFLUX AND MG2+ INFLUX
    GUNTHER, T
    MINERAL AND ELECTROLYTE METABOLISM, 1993, 19 (4-5) : 259 - 265
  • [13] A simple fluorescent receptor selective for Mg2+
    Ma, Yingying
    Liu, Hong
    Liu, Shaopu
    Yang, Rui
    ANALYST, 2012, 137 (10) : 2313 - 2317
  • [14] THE USE OF MAG-FURA-2 TO MEASURE THE INTRACELLULAR MG2+ CONCENTRATION [MG2+]I IN ISOLATED GUINEA-PIG VENTRICULAR MYOCYTES
    BURI, A
    FRY, CH
    MCGUIGAN, JAS
    NOBLE, D
    POWELL, T
    TWIST, VW
    JOURNAL OF PHYSIOLOGY-LONDON, 1991, 438 : P76 - P76
  • [15] Mg2+ sensing by the Mg2+ sensor PhoQ of Salmonella enterica
    Chamnongpol, S
    Cromie, M
    Groisman, EA
    JOURNAL OF MOLECULAR BIOLOGY, 2003, 325 (04) : 795 - 807
  • [16] The new methods of determination of Mg2+, Ca2+, Na+ and K+ ions in erythrocytes by ion selective electrodes
    Malon, A
    Maj-Zurawska, M
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2) : 828 - 831
  • [17] Sphingolipids regulate [Mg2+]o uptake and [Mg2+]i content in vascular smooth muscle cells: potential mechanisms and importance to membrane transport of Mg2+
    Zheng, Tao
    Li, Wenyan
    Altura, Bella T.
    Shah, Nilank C.
    Altura, Burton M.
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2011, 300 (02): : H486 - H492
  • [18] Prussian Blue Analogues as Positive Electrodes for Mg Batteries: Insights into Mg2+ Intercalation
    Trocoli, Rafael
    Houdeville, Raphaelle
    Frontera, Carlos
    Vincent, Smobin
    Garcia Lastra, Juan Maria
    Palacin, M. Rosa
    CHEMSUSCHEM, 2024, 17 (05)
  • [19] Sphingolipids regulate [Mg2+]o uptake and [Mg2+]i content in vascular smooth muscle cells
    Zheng, T
    Li, WY
    Altura, BT
    Altura, BM
    FASEB JOURNAL, 2002, 16 (04): : A273 - A273
  • [20] SEQUENCE SELECTIVE COORDINATION OF MG2+(AQ) TO DNA
    COWAN, JA
    HUANG, HW
    HSU, LY
    JOURNAL OF INORGANIC BIOCHEMISTRY, 1993, 52 (02) : 121 - 129