Midterm results of aortic valve replacement with Carpentier-Edwards porcine bioprosthesis

被引:0
|
作者
Sakata J. [1 ]
Tsukamoto M. [1 ]
Kuwaki K. [1 ]
Komatsu K. [1 ]
Harada N. [1 ]
Abe T. [1 ]
机构
[1] Department of Cardiovascular Surgery, Sapporo Med. Univ. Sch. of Medicine, Sapporo 060-8543, South 1, West 16, Chuo-ku
关键词
Bioprosthesis; Carpentier-Edwards valve; Midterm results;
D O I
10.1007/s100470200046
中图分类号
学科分类号
摘要
Since 1987 we have been using Carpentier-Edwards porcine bioprostheses for aortic valve replacements in patients of advanced age and those with a contraindication for anticoagulation therapy. The purpose of this study was to provide insight into the midterm results of our series of patients with Carpentier-Edwards porcine bioprostheses in the aortic position. From September 1987 through June 1999, 31 patients underwent aortic valve replacement with Capentier-Edwards porcine bioprostheses. The age of the patients ranged from 21 to 89 (average, 71 ± 11 years old), and 21 patients (67.7%) were 70 years old or older. There were no operative deaths. Three hospital deaths (9.7%) and one nonhospital death (3.2%) took place. The actuarial survival rate of 31 patients was 90.3% at 5 years and 81.3% at 7 years. Valve-related complications were seen in six patients (19.4%). The postoperative Doppler peak gradient of aortic prostheses was less than 30 mm Hg in all groups, irrespective of valve size. In conclusion, the Carpentier-Edwards porcine bioprosthesis affords good durability with a low rate of valve-related complications and reoperation. Furthermore, the postoperative function of the prosthesis was reasonable in the Doppler echo studies. © The Japanese Society for Artificial Organs 2002.
引用
收藏
页码:246 / 250
页数:4
相关论文
共 50 条
  • [21] Thromboembolic events after aortic valve replacement in elderly patients with a Carpentier-Edwards perimount pericardial bioprosthesis
    Mistiaen, W
    Van Cauwelaert, P
    Muylaert, P
    Sys, SU
    Harrisson, F
    Bortier, H
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 127 (04): : 1166 - 1170
  • [22] Pannus overgrowth after mitral valve replacement with a Carpentier-Edwards pericardial bioprosthesis
    Takeshi Oda
    Seiya Kato
    Eiki Tayama
    Shuji Fukunaga
    Hidetoshi Akashi
    Shigeaki Aoyagi
    Journal of Artificial Organs, 2009, 12 : 55 - 57
  • [23] HEMODYNAMIC ASSESSMENT OF CARPENTIER-EDWARDS BIOPROSTHESIS IN AORTIC POSITION
    GREHL, T
    LEE, G
    JOYE, JA
    DEMARIA, AN
    HURLEY, E
    KAKU, R
    HARTER, W
    WALLACE, S
    MASON, DT
    CLINICAL RESEARCH, 1978, 26 (02): : A92 - A92
  • [24] HEMODYNAMIC ASSESSMENT OF THE NEW AORTIC CARPENTIER-EDWARDS BIOPROSTHESIS
    LEE, G
    GREHL, TM
    JOYE, JA
    KAKU, RF
    HARTER, W
    DEMARIA, AN
    MASON, DT
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1978, 4 (04): : 373 - 381
  • [25] HEMODYNAMIC EVALUATION OF THE CARPENTIER-EDWARDS BIOPROSTHESIS IN THE AORTIC POSITION
    ROTHKOPF, M
    DAVIDSON, T
    LIPSCOMB, K
    NARAHARA, K
    HILLIS, LD
    WILLERSON, JT
    ESTRERA, A
    PLATT, M
    MILLS, L
    AMERICAN JOURNAL OF CARDIOLOGY, 1979, 44 (02): : 209 - 214
  • [26] HEMODYNAMIC ASSESSMENT OF CARPENTIER-EDWARDS BIOPROSTHESIS IN AORTIC POSITION
    JOYE, JA
    LEE, G
    GREHL, T
    DEMARIA, AN
    HURLEY, E
    KAKU, R
    HARTER, W
    WALLACE, S
    MASON, DT
    CLINICAL RESEARCH, 1978, 26 (03): : A241 - A241
  • [27] Performance of the Carpentier-Edwards SAV and Hancock-II porcine bioprostheses in aortic valve replacement
    Jamieson, WRE
    David, TE
    Feindel, CMS
    Miyagishima, RT
    Germann, E
    JOURNAL OF HEART VALVE DISEASE, 2002, 11 (03): : 424 - 430
  • [28] AGE AS A DETERMINANT FOR SELECTION OF PORCINE BIOPROSTHESES FOR CARDIAC-VALVE REPLACEMENT - EXPERIENCE WITH CARPENTIER-EDWARDS STANDARD BIOPROSTHESIS
    JAMIESON, WRE
    TYERS, GFO
    JANUSZ, MT
    MIYAGISHIMA, RT
    MUNRO, AI
    LING, H
    BURR, LH
    TUTASSAURA, H
    CANADIAN JOURNAL OF CARDIOLOGY, 1991, 7 (04) : 181 - 188
  • [29] EXPERIENCE WITH 813 AORTIC OR MITRAL-VALVE REPLACEMENTS WITH THE CARPENTIER-EDWARDS BIOPROSTHESIS - 5 YEAR RESULTS
    SOOTS, G
    PIERONNE, A
    ROUX, JP
    STANKOWIAK, C
    WAREMBOURG, H
    WATEL, A
    PRAT, A
    SEGBEYA, A
    MAATOUK, M
    CREPIN, F
    EUROPEAN HEART JOURNAL, 1984, 5 : 87 - 94
  • [30] CARPENTIER-EDWARDS STANDARD PORCINE BIOPROSTHESIS - EVALUATION OF VALVE-RELATED MORBIDITY AND MORTALITY
    JAMIESON, WRE
    MIYAGISHIMA, RT
    TYERS, GFO
    CHAN, F
    MACNAB, J
    JANUSZ, MT
    GEREIN, AN
    CLINICAL AND INVESTIGATIVE MEDICINE-MEDECINE CLINIQUE ET EXPERIMENTALE, 1986, 9 (03): : A7 - A7