A fast-neutron coincidence collar using liquid scintillators for fresh fuel verification

被引:0
|
作者
Jonathan S. Beaumont
Tae Hoon Lee
Mikhail Mayorov
Carlo Tintori
Francesco Rogo
Bruno Angelucci
Matteo Corbo
机构
[1] International Atomic Energy Agency,
[2] CAEN S.p.A,undefined
关键词
Safeguards; Non-destructive assay; Uranium assay; Neutron coincidence counting; Fast-neutron detection; Burnable neutron poisons;
D O I
暂无
中图分类号
学科分类号
摘要
The IAEA has developed a liquid scintillator-based system for the non-destructive assay of 235U in fresh fuel assemblies. The fast neutron coincidence collar (FNCL) addresses current limitations in existing neutron coincidence counting techniques when measuring fuel containing burnable neutron poisons. Detection of fast neutrons rather than thermal neutrons allows the minimisation of measurement time and biases (due to effects of burnable poisons). The FNCL hardware, software and instrument optimisation are discussed. Experimental results from measurements of mock-up uranium fuel assemblies at the institute for transuranium elements, Karlsruhe, Germany with varying 235U enrichment and burnable neutron poison content are presented.
引用
收藏
页码:803 / 812
页数:9
相关论文
共 50 条
  • [21] Low-Afterglow, High-Refractive-Index Liquid Scintillators for Fast-Neutron Spectrometry and Imaging Applications
    Lauck, Ronald
    Brandis, Michal
    Bromberger, Benjamin
    Dangendorf, Volker
    Goldberg, Mark B.
    Mor, Ilan
    Tittelmeier, Kai
    Vartsky, David
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 989 - 993
  • [22] Development of the Fast-Neutron Reactors Fuel Cycle.
    Barbe, Alain
    Bernard, Henri
    Boulinier, Claude
    Prouteau, Lucien
    Revue Generale Nucleaire, 1987, (03): : 258 - 262
  • [23] A FAST-NEUTRON DETECTOR USED IN VERIFICATION OF THE INF-TREATY
    EWING, RI
    MARLOW, KW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 299 (1-3): : 559 - 561
  • [24] Fast-neutron multiplicity analysis based on liquid scintillation
    Li, Sufen
    Qiu, Suizheng
    Zhang, Quanhu
    Huo, Yonggang
    Lin, Hongtao
    APPLIED RADIATION AND ISOTOPES, 2016, 110 : 53 - 58
  • [25] A LIQUID-HELIUM SCINTILLATOR AS A FAST-NEUTRON POLARIMETER
    IEKI, K
    HOSHINO, N
    IWASE, M
    OHNUMA, H
    TAKAHASHI, Y
    ORIHARA, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 262 (2-3): : 323 - 328
  • [26] THE FAST-NEUTRON REACTOR-FUEL ELEMENT AND ITS BEHAVIOR
    LECLERE, J
    MILLET, P
    ANNALES DE CHIMIE-SCIENCE DES MATERIAUX, 1984, 9 (04): : 423 - 431
  • [27] SWELLING OF FUEL CLADDING ALLOYS DURING FAST-NEUTRON IRRADIATION
    WOLFF, UE
    WITHOP, A
    LAURITZE.TA
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1969, 12 (01): : 114 - &
  • [28] MECHANICAL-BEHAVIOR OF THE FUEL CLADDING OF FAST-NEUTRON REACTORS
    CAUVIN, R
    BOUTARD, JL
    ANNALES DE CHIMIE-SCIENCE DES MATERIAUX, 1984, 9 (04): : 449 - 461
  • [29] TESTING PLUTONIUM FUEL ASSEMBLY PRODUCTION FOR FAST-NEUTRON REACTORS
    NOUGUES, B
    BENHAMOU, A
    BERTOTHY, G
    LEPETIT, H
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1975, 20 (APR21): : 574 - 576
  • [30] FAST-NEUTRON DOSIMETRY USING ACTIVATED THERMOLUMINESCENCE
    PEARSON, D
    WAGNER, J
    MORAN, PR
    CAMERON, JR
    HEALTH PHYSICS, 1973, 25 (03): : 304 - 304