Radiochemical determination of lead-210 in environmental water samples using Cerenkov counting

被引:0
|
作者
M. S. Al-Marri
A. Hamwi
H. Mikhallaty
机构
[1] Atomic Energy Comission of Syria,Department of Radiation Protection and Nuclear Safety
关键词
EDTA; Water Sample; Tritium; Alkaline Solution; Environmental Water;
D O I
暂无
中图分类号
学科分类号
摘要
A relatively simple method has been developed for the determination of210Pb via its β-emitting daughter,210Bi. Lead-210 was separated from interfering elements as lead sulphate. The precipitate was dissolved in an alkaline solution of EDTA and the Cerenkov signal produced by the build-up of210Bi was counted 30 days after storage using tritium channel of a liquid scintillation counter. Cerenkov counting efficiency was found to be approximately 20%. A lower limit of detection of 5.1 mBq/1 (based on 3σ of the background with 500 minute counting time) was achieved. Chemical recoveries in the range of 70–100% were determined gravimetrically. Interference associated with currently used methods is avoided. Data from from both spiked samples and natural samples are presented.
引用
收藏
页码:73 / 75
页数:2
相关论文
共 50 条
  • [31] Determination of 210Po and 210Pb in hydrometallurgical samples using liquid scintillation counting
    S. A. Brown
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 264 : 505 - 509
  • [32] Determination of lake sediment accumulation rates in an agricultural watershed using lead-210 and cesium-137
    Wren, D. G.
    Rigby, J. R.
    Davidson, G. R.
    Locke, M. A.
    JOURNAL OF SOIL AND WATER CONSERVATION, 2016, 71 (02) : 137 - 147
  • [33] Determination of lead-210 and its progenies in aerosol fractions of different particles sizes
    Wallner, G
    Irlweck, K
    RADIOCHIMICA ACTA, 1997, 78 : 173 - 176
  • [34] Rapid determination of strontium-90 in environmental samples by single Cerenkov counting using two different colour quench curves
    Torres, JM
    Garcia, JF
    Llaurado, M
    Rauret, G
    ANALYST, 1996, 121 (11) : 1737 - 1742
  • [35] 90Sr determination in water samples using Cerenkov radiation
    Todorovic, Natasa
    Stojkovic, Ivana
    Nikolov, Jovana
    Tenjovic, Branislava
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2017, 169 : 197 - 202
  • [36] DETERMINATION OF BLUE CARBON SEQUESTRATION RATES IN THE UK NORTH SEA USING LEAD-210 AND COMPLEMENTARY FINGERPRINTING TOOLS
    Dal Molin, Franck
    Blowers, Paul
    Brady, Daniel
    Brown, Nathan
    Cogan, Stephanie
    Davis, Terri
    Hamstead, Peter
    Huk, Mariusz
    Limbach, Hannah
    Smedley, Paul
    ENVIRONMENTAL RADIOCHEMICAL ANALYSIS VII, ERA14, 2024, 357 : 69 - 85
  • [37] DETERMINATION OF LEAD IN ENVIRONMENTAL SAMPLES
    BOGEN, DC
    KANTELO, MV
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1969, (APR): : AN30 - &
  • [38] Determination of 210Pb in environmental samples
    Ebaid, Y. Y.
    Khater, A. E. M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2006, 270 (03) : 609 - 619
  • [39] Determination of 210Pb in environmental samples
    Y. Y. Ebaid
    A. E. M. Khater
    Journal of Radioanalytical and Nuclear Chemistry, 2006, 270 : 609 - 619
  • [40] Determination of 210Po and 210Pb in hydro metallurgical samples using liquid scintillation counting
    Brown, SA
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 264 (02) : 505 - 509