Photon beam dosimetry with EBT3 film in heterogeneous regions: Application to the evaluation of dose-calculation algorithms

被引:0
|
作者
Hyunuk Jung
Oyeon Kum
Youngyih Han
Byungdo Park
Kwang-Ho Cheong
机构
[1] Sungkyunkwan University,Department of Health Sciences and Technology
[2] Korea Institute of Radiological and Medical Sciences,Heavy
[3] Sungkyunkwan University School of Medicine,ion Medical Accelerator Development Center
[4] Sungkyunkwan University School of Medicine,Department of Radiation Oncology, Samsung Medical Center
[5] Hallym University College of Medicine,Department of Radiation Oncology, Samsung Changwon Hospital
来源
关键词
EBT3; Heterogeneity; Film dosimetry; Monte Carlo simulation; Radiation treatment planning;
D O I
暂无
中图分类号
学科分类号
摘要
For a better understanding of the accuracy of state-of-the-art-radiation therapies, 2-dimensional dosimetry in a patient-like environment will be helpful. Therefore, the dosimetry of EBT3 films in non-water-equivalent tissues was investigated, and the accuracy of commercially-used dose-calculation algorithms was evaluated with EBT3 measurement. Dose distributions were measured with EBT3 films for an in-house-designed phantom that contained a lung or a bone substitute, i.e., an air cavity (3 × 3 × 3 cm3) or teflon (2 × 2 × 2 cm3 or 3 × 3 × 3 cm3), respectively. The phantom was irradiated with 6-MV X-rays with field sizes of 2 × 2, 3 × 3, and 5 × 5 cm2. The accuracy of EBT3 dosimetry was evaluated by comparing the measured dose with the dose obtained from Monte Carlo (MC) simulations. A dose-to-bone-equivalent material was obtained by multiplying the EBT3 measurements by the stopping power ratio (SPR). The EBT3 measurements were then compared with the predictions from four algorithms: Monte Carlo (MC) in iPlan, acuros XB (AXB), analytical anisotropic algorithm (AAA) in Eclipse, and superposition-convolution (SC) in Pinnacle. For the air cavity, the EBT3 measurements agreed with the MC calculation to within 2% on average. For teflon, the EBT3 measurements differed by 9.297% (±0.9229%) on average from the Monte Carlo calculation before dose conversion, and by 0.717% (±0.6546%) after applying the SPR. The doses calculated by using the MC, AXB, AAA, and SC algorithms for the air cavity differed from the EBT3 measurements on average by 2.174, 2.863, 18.01, and 8.391%, respectively; for teflon, the average differences were 3.447, 4.113, 7.589, and 5.102%. The EBT3 measurements corrected with the SPR agreed with 2% on average both within and beyond the heterogeneities with MC results, thereby indicating that EBT3 dosimetry can be used in heterogeneous media. The MC and the AXB dose calculation algorithms exhibited clinically-acceptable accuracy (<5%) in heterogeneities.
引用
收藏
页码:1829 / 1838
页数:9
相关论文
共 50 条
  • [1] Photon Beam Dosimetry with EBT3 Film in Heterogeneous Regions: Application to the Evaluation of Dose-calculation Algorithms
    Jung, Hyunuk
    Kum, Oyeon
    Han, Youngyih
    Park, Byungdo
    Cheong, Kwang-Ho
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (11) : 1829 - 1838
  • [2] External Photon Beam Dosimetry for Linac QA Using Gafchromic EBT3 Film
    Khan, I.
    Tahir, B.
    Rafique, M.
    Iqbal, T.
    Zulfiqar, S.
    Zahoor, A.
    Rehman, J.
    Iqbal, K.
    Chow, J.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E309 - E309
  • [3] Ion beam dosimetry using Gafchromic EBT3 film
    Hassan, M. G.
    El-Saftawy, A. A.
    Soliman, B. A.
    Abdelrahman, M. M.
    Abdelmageed, K. E.
    Hassouba, M. A.
    [J]. APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2024, 130 (06):
  • [4] Commissioning and evaluation of a radiochromic EBT3 film dosimetry system
    Khan, Muhammad Isa
    Tahir, Muhammad Bilal
    Rafique, Muhammad
    Iqbal, Tahir
    Zulfiqar, Sabiha
    Zahoor, Aliza
    Rehman, Jalil Ur
    Iqba, Khalid
    Chow, James
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (01) : 55 - 62
  • [5] Characteristic of EBT-XD and EBT3 radiochromic film dosimetry for photon and proton beams
    Khachonkham, Suphalak
    Dreindl, Ralf
    Heilemann, Gerd
    Lechner, Wolfgang
    Fuchs, Hermann
    Palmans, Hugo
    Georg, Dietmar
    Kuess, Peter
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (06):
  • [6] An inexpensive method of small photon field dosimetry with EBT3 radiochromic film
    Mourya A.
    Aggarwal L.M.
    Mandal A.
    Shahi U.P.
    Ram C.
    Asthana A.K.
    Pradhan S.
    [J]. Health and Technology, 2018, 8 (3) : 171 - 177
  • [7] In vivo Dosimetry for Dose Verification of Total Skin Electron Beam Therapy Using Gafchromic® EBT3 Film Dosimetry
    Baba, Misba Hamid
    Singh, Benoy Kumar
    Wani, Shaqul Qamar
    [J]. JOURNAL OF MEDICAL PHYSICS, 2022, 47 (04) : 362 - 366
  • [8] Investigation of the CyberKnife MultiPlan Monte Carlo Dose Calculation Using EBT3 Film Absolute Dosimetry for Delivery in a Heterogeneous Thorax Phantom
    Lamberto, M.
    Chen, H.
    Huang, K.
    Mourtada, F.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3454 - 3454
  • [9] Evaluation of Gafchromic EBT-XD film, with comparison to EBT3 film, and application in high dose radiotherapy verification
    Palmer, Antony L.
    Dimitriadis, Alexis
    Nisbet, Andrew
    Clark, Catharine H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (22): : 8741 - 8752
  • [10] Linearization of EBT3 film dose response and virtual film dosimetry for SBRT quality assurance
    Cai, M.
    Archibald-Heeren, B.
    Wang, Y.
    Metcalfe, P.
    [J]. MICRO-MINI & NANO-DOSIMETRY & INNOVATIVE TECHNOLOGIES IN RADIATION THERAPY (MMND&ITRO2016), 2017, 777