Patient-specific geometrical modeling of orthopedic structures with high efficiency and accuracy for finite element modeling and 3D printing

被引:0
|
作者
Huajun Huang
Chunling Xiang
Canjun Zeng
Hanbin Ouyang
Kelvin Kian Loong Wong
Wenhua Huang
机构
[1] The Third Affiliated Hospital of Southern Medical University (Academy of Orthopedics · Guangdong Province),Department of Orthopedics
[2] Southern Medical University,Department of Orthopedics and Traumatology, Nanfang Hospital
[3] Southern Medical University,Department of Anatomy, Guangdong Provincial Key Laboratory of Medical Biomechanics, School of Basic Medical Sciences
[4] The University of Western Australia,Engineering Computational Biology, School of Computer Science and Software Engineering
来源
Australasian Physical & Engineering Sciences in Medicine | 2015年 / 38卷
关键词
Orthopedic reconstruction; Image segmentation; Digitalization; Medical imaging; Mesh quality;
D O I
暂无
中图分类号
学科分类号
摘要
We improved the geometrical modeling procedure for fast and accurate reconstruction of orthopedic structures. This procedure consists of medical image segmentation, three-dimensional geometrical reconstruction, and assignment of material properties. The patient-specific orthopedic structures reconstructed by this improved procedure can be used in the virtual surgical planning, 3D printing of real orthopedic structures and finite element analysis. A conventional modeling consists of: image segmentation, geometrical reconstruction, mesh generation, and assignment of material properties. The present study modified the conventional method to enhance software operating procedures. Patient’s CT images of different bones were acquired and subsequently reconstructed to give models. The reconstruction procedures were three-dimensional image segmentation, modification of the edge length and quantity of meshes, and the assignment of material properties according to the intensity of gravy value. We compared the performance of our procedures to the conventional procedures modeling in terms of software operating time, success rate and mesh quality. Our proposed framework has the following improvements in the geometrical modeling: (1) processing time: (femur: 87.16 ± 5.90 %; pelvis: 80.16 ± 7.67 %; thoracic vertebra: 17.81 ± 4.36 %; P < 0.05); (2) least volume reduction (femur: 0.26 ± 0.06 %; pelvis: 0.70 ± 0.47, thoracic vertebra: 3.70 ± 1.75 %; P < 0.01) and (3) mesh quality in terms of aspect ratio (femur: 8.00 ± 7.38 %; pelvis: 17.70 ± 9.82 %; thoracic vertebra: 13.93 ± 9.79 %; P < 0.05) and maximum angle (femur: 4.90 ± 5.28 %; pelvis: 17.20 ± 19.29 %; thoracic vertebra: 3.86 ± 3.82 %; P < 0.05). Our proposed patient-specific geometrical modeling requires less operating time and workload, but the orthopedic structures were generated at a higher rate of success as compared with the conventional method. It is expected to benefit the surgical planning of orthopedic structures with less operating time and high accuracy of modeling.
引用
收藏
页码:743 / 753
页数:10
相关论文
共 50 条
  • [21] Method for patient-specific finite element modeling and simulation of deep brain stimulation
    Mattias Åström
    Ludvic U. Zrinzo
    Stephen Tisch
    Elina Tripoliti
    Marwan I. Hariz
    Karin Wårdell
    Medical & Biological Engineering & Computing, 2009, 47 : 21 - 28
  • [22] Anisotropic Finite Element Modeling Based on a Harmonic Field for Patient-Specific Sclera
    Jia, Xu
    Liao, Shenghui
    Duan, Xuanchu
    Zheng, Wanqiu
    Zou, Beiji
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [23] Method for patient-specific finite element modeling and simulation of deep brain stimulation
    Astrom, Mattias
    Zrinzo, Ludvic U.
    Tisch, Stephen
    Tripoliti, Elina
    Hariz, Marwan I.
    Wardell, Karin
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2009, 47 (01) : 21 - 28
  • [24] Female patient-specific finite element modeling of pelvic organ prolapse (POP)
    Chen, Zhuo-Wei
    Joli, Pierre
    Feng, Zhi-Qiang
    Rahim, Mehdi
    Pirro, Nicolas
    Bellemare, Marc-Emmanuel
    JOURNAL OF BIOMECHANICS, 2015, 48 (02) : 238 - 245
  • [25] Quality Control in 3D Printing: Accuracy Analysis of 3D-Printed Models of Patient-Specific Anatomy
    Dorweiler, Bernhard
    Baque, Pia Elisabeth
    Chaban, Rayan
    Ghazy, Ahmed
    Salem, Oroa
    MATERIALS, 2021, 14 (04) : 1 - 13
  • [26] A NUMERICAL AND 3D PRINTING FRAMEWORK FOR THE IN VIVO MECHANICAL ASSESSMENT OF PATIENT-SPECIFIC CARDIOVASCULAR STRUCTURES
    Fanni, Benigno M.
    Sauvage, Emilie
    Capelli, Claudio
    Gasparotti, Emanuele
    Vignali, Emanuele
    Schievano, Silvia
    Landini, Luigi
    Positano, Vincenzo
    Celi, Simona
    SECOND INTERNATIONAL CONFERENCE ON SIMULATION FOR ADDITIVE MANUFACTURING (SIM-AM 2019), 2019, : 31 - 39
  • [27] Automated generation of 3D bone models from planar X-ray images for patient-specific finite element modeling applications
    Galibarov, Re.
    Lennon, A. B.
    Prendergast, P. J.
    COMPUTATIONAL MODELLING OF OBJECTS REPRESENTED IN IMAGES: FUNDAMENTALS, METHODS AND APPLICATIONS, 2007, : 191 - 195
  • [28] Sub-modeling Finite Element Analysis of 3D Printed Structures
    Zarbakhsh, Javad
    Iravani, Armin
    Amin-Akhlaghi, Zeinab
    2015 16TH INTERNATIONAL CONFERENCE ON THERMAL, MECHANICAL AND MULTI-PHYSICS SIMULATION AND EXPERIMENTS IN MICROELECTRONICS AND MICROSYSTEMS (EUROSIME), 2015,
  • [29] 3D FINITE-ELEMENT MODELING OF CONDUCTING SUPPORT STRUCTURES IN COILGUNS
    HAINSWORTH, G
    RODGER, D
    LEONARD, PJ
    IEEE TRANSACTIONS ON MAGNETICS, 1995, 31 (03) : 2052 - 2055
  • [30] 3D finite element modeling and analysis of dynamic force in bone drilling for orthopedic surgery
    Qi, Lin
    Wang, Xiaona
    Meng, Max Q.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2014, 30 (09) : 845 - 856