Patient-specific geometrical modeling of orthopedic structures with high efficiency and accuracy for finite element modeling and 3D printing

被引:0
|
作者
Huajun Huang
Chunling Xiang
Canjun Zeng
Hanbin Ouyang
Kelvin Kian Loong Wong
Wenhua Huang
机构
[1] The Third Affiliated Hospital of Southern Medical University (Academy of Orthopedics · Guangdong Province),Department of Orthopedics
[2] Southern Medical University,Department of Orthopedics and Traumatology, Nanfang Hospital
[3] Southern Medical University,Department of Anatomy, Guangdong Provincial Key Laboratory of Medical Biomechanics, School of Basic Medical Sciences
[4] The University of Western Australia,Engineering Computational Biology, School of Computer Science and Software Engineering
来源
Australasian Physical & Engineering Sciences in Medicine | 2015年 / 38卷
关键词
Orthopedic reconstruction; Image segmentation; Digitalization; Medical imaging; Mesh quality;
D O I
暂无
中图分类号
学科分类号
摘要
We improved the geometrical modeling procedure for fast and accurate reconstruction of orthopedic structures. This procedure consists of medical image segmentation, three-dimensional geometrical reconstruction, and assignment of material properties. The patient-specific orthopedic structures reconstructed by this improved procedure can be used in the virtual surgical planning, 3D printing of real orthopedic structures and finite element analysis. A conventional modeling consists of: image segmentation, geometrical reconstruction, mesh generation, and assignment of material properties. The present study modified the conventional method to enhance software operating procedures. Patient’s CT images of different bones were acquired and subsequently reconstructed to give models. The reconstruction procedures were three-dimensional image segmentation, modification of the edge length and quantity of meshes, and the assignment of material properties according to the intensity of gravy value. We compared the performance of our procedures to the conventional procedures modeling in terms of software operating time, success rate and mesh quality. Our proposed framework has the following improvements in the geometrical modeling: (1) processing time: (femur: 87.16 ± 5.90 %; pelvis: 80.16 ± 7.67 %; thoracic vertebra: 17.81 ± 4.36 %; P < 0.05); (2) least volume reduction (femur: 0.26 ± 0.06 %; pelvis: 0.70 ± 0.47, thoracic vertebra: 3.70 ± 1.75 %; P < 0.01) and (3) mesh quality in terms of aspect ratio (femur: 8.00 ± 7.38 %; pelvis: 17.70 ± 9.82 %; thoracic vertebra: 13.93 ± 9.79 %; P < 0.05) and maximum angle (femur: 4.90 ± 5.28 %; pelvis: 17.20 ± 19.29 %; thoracic vertebra: 3.86 ± 3.82 %; P < 0.05). Our proposed patient-specific geometrical modeling requires less operating time and workload, but the orthopedic structures were generated at a higher rate of success as compared with the conventional method. It is expected to benefit the surgical planning of orthopedic structures with less operating time and high accuracy of modeling.
引用
收藏
页码:743 / 753
页数:10
相关论文
共 50 条
  • [1] Patient-specific geometrical modeling of orthopedic structures with high efficiency and accuracy for finite element modeling and 3D printing
    Huang, Huajun
    Xiang, Chunling
    Zeng, Canjun
    Ouyang, Hanbin
    Wong, Kelvin Kian Loong
    Huang, Wenhua
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2015, 38 (04) : 743 - 753
  • [2] Patient-specific finite element modeling of bones
    Poelert, Sander
    Valstar, Edward
    Weinans, Harrie
    Zadpoor, Amir A
    Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2012, 227 (04) : 464 - 478
  • [3] Patient-specific finite element modeling of bones
    Poelert, Sander
    Valstar, Edward
    Weinans, Harrie
    Zadpoor, Amir A.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H4) : 464 - 478
  • [4] Anisotropic finite element modeling for patient-specific mandible
    Liao, Sheng-Hui
    Tong, Ruo-Feng
    Dong, Jin-Xiang
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2007, 88 (03) : 197 - 209
  • [5] Finite element modeling of 3D interconnection structures
    Tan, JL
    Pan, GW
    ICMMT'98: 1998 INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY PROCEEDINGS, 1998, : 957 - 960
  • [6] How specific are patient-specific simulations? Analyzing the accuracy of 3D-printing and modeling to create patient-specific rehearsals for complex urological procedures
    Melnyk, Rachel
    Oppenheimer, Daniel
    Ghazi, Ahmed E.
    WORLD JOURNAL OF UROLOGY, 2022, 40 (03) : 621 - 626
  • [7] How specific are patient-specific simulations? Analyzing the accuracy of 3D-printing and modeling to create patient-specific rehearsals for complex urological procedures
    Rachel Melnyk
    Daniel Oppenheimer
    Ahmed E. Ghazi
    World Journal of Urology, 2022, 40 : 621 - 626
  • [8] Automating 3d meshing method for patient-specific modeling
    Guan, Yabo
    Zhang, Jiangyue
    Yoganandan, Narayan
    Pintar, Frank A.
    BIOMEDICAL SCIENCES INSTRUMENTATION, VOL 42, 2006, 42 : 199 - 204
  • [9] Patient-specific finite element modeling for femoral bone augmentation
    Basafa, Ehsan
    Armiger, Robert S.
    Kutzer, Michael D.
    Belkoff, Stephen M.
    Mears, Simon C.
    Armand, Mehran
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (06) : 860 - 865
  • [10] Applications of patient-specific 3D printing in medicine
    Heller, M.
    Bauer, H-K.
    Goetze, E.
    Gielisch, M.
    Roth, K. E.
    Maier, G. S.
    Drees, P.
    Dorweiler, B.
    Ghazy, A.
    Neufurth, M.
    Mueller, W. E. G.
    Schoerder, H. C.
    Wang, X. H.
    Vahl, C-F
    Al-Nawas, B.
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2016, 19 (04) : 323 - 339