Performance of Three-Phase Motors after Disconnecting Damaged Coils

被引:0
|
作者
Kai Brune
Hans Otto Seinsch
机构
[1] Siemens AG,A&D LD TD2
[2] Universität Hannover,Institut für Antriebssysteme und Leistungselektronik
来源
Electrical Engineering | 2007年 / 89卷
关键词
Winding faults; Winding asymmetry; Cut out coils; Disconnection of winding branches; Current distribution; Harmonic torques; Pulsating torques; Unbalanced magnetic pull;
D O I
暂无
中图分类号
学科分类号
摘要
Despite the high quality of modern insulation systems, winding faults still represent the most frequent reason of outages of rotating electrical machines. When the damage is localized at one coil or a few adjacent coils, the user wishes to investigate the possibility of a provisional repair, in order to continue operation at least for a limited period of time. Up to now no reliable tools are available to predict the performance of a motor when one or more coils are disconnected from the winding train.
引用
收藏
页码:271 / 283
页数:12
相关论文
共 50 条
  • [1] Performance of three-phase motors after disconnecting damaged coils
    Brune, Kai
    Seinsch, Hans Otto
    [J]. ELECTRICAL ENGINEERING, 2007, 89 (04) : 271 - 283
  • [2] Magnetic loading of fractional-slot three-phase PM motors with nonoverlapped coils
    Bianchi, Nicola
    Bolognani, Silverio
    Pre, Michele Dai
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2008, 44 (05) : 1513 - 1521
  • [3] Performance Analysis of Synchronous Machines After Disconnecting Stator Coils
    Misir, Onur
    Raziee, Seyed Morteza
    Spyridonidis, Ioannis
    Brand, Jennifer
    Bothmann, Fabian
    Dreyer, Malte
    Ponick, Bernd
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (05) : 4315 - 4323
  • [4] Three-phase electromagnetic AC motors
    Smirnov Y.V.
    [J]. Russian Electrical Engineering, 2009, 80 (5) : 244 - 246
  • [5] Effects of Unbalanced Voltages on the Energy Performance of Three-phase Induction Motors
    Quispe, Enrique C.
    Lopez, Ivan D.
    [J]. 2015 IEEE WORKSHOP ON POWER ELECTRONICS AND POWER QUALITY APPLICATIONS (PEPQA), 2015,
  • [6] Magnetic loading of fractional-slot three-phase PM motors with non-overlapped coils
    Bianchi, Nicola
    Bolognani, Silverio
    Pre, Michele Dai
    [J]. CONFERENCE RECORD OF THE 2006 IEEE INDUSTRY APPLICATIONS CONFERENCE, FORTY-FIRST IAS ANNUAL MEETING, VOL 1-5, 2006, : 35 - 43
  • [7] Predicting performance of three-phase induction motors connected to single-phase supplies
    Alwash, JHH
    [J]. IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 1996, 143 (04): : 339 - 344
  • [8] Determination of Parameters of Three-Phase Asynchronous Motors
    Burkov, Aleksei F.
    Kraskovskiy, Mikhail, V
    Yurin, Valery N.
    [J]. 2019 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2019,
  • [9] Three-phase induction motors put on the brakes
    Komander, S.
    [J]. Motion System Design, 2001, 43 (08): : 27 - 30
  • [10] Three-phase electromagnetic switched reluctance motors
    Smirnov Y.V.
    [J]. Russian Electrical Engineering, 2009, 80 (11) : 601 - 603