Optimized acquisition and processing protocols for I-123 cardiac SPECT imaging

被引:2
|
作者
Chen J. [1 ]
Garcia E.V. [1 ]
Galt J.R. [1 ]
Folks R.D. [1 ]
Carrio I. [2 ]
机构
[1] Department of Radiology, Emory University, School of Medicine, Atlanta, GA 30322
[2] Hospital De Sant Pau, Barcelona
关键词
Deconvolution of septal penetration; Iodine; 123; Low-energy high-resolution collimator; Single photon emission computed tomography;
D O I
10.1007/BF02971250
中图分类号
学科分类号
摘要
Background: Deconvolution of septal penetration (DSP) has been developed to improve quantification so as to allow the use of low-energy high-resolution collimators for iodine 123 cardiac single photon emission computed tomography (SPECT) imaging. The purpose of this study is to optimize its acquisition and processing protocols. Methods and Results: Planar images of a 9-compartment phantom loaded with variable radioactive concentrations were acquired to derive optimal scatter compensation scaling factors for 20% and 15% photopeak energy window configurations, respectively. A cardiac phantom, loaded with high and low heart-to-calibration ratios (HCRs), respectively, was imaged with both configurations. Repeated acquisitions were done for medium-energy all-purpose collimators for comparison. Critical frequencies for Butterworth filtering were optimized by use of defect contrast and normal short-axis uniformity as selection indices. HCRs were calculated with planar projection and different reconstruction methods, respectively, and then compared with the true HCRs. SPECT produced more accurate HCRs than planar imaging. With the optimized parameters for scatter compensation and filtering, the 2 energy window configurations yielded similar results. Iterative reconstructions with DSP yielded more accurate HCRs than other reconstructions without DSP. Conclusion: The optimized protocols based on DSP show promise that quantification of I-123 cardiac SPECT imaging can be achieved with the widely available low-energy high-resolution collimators. Copyright © 2006 by the American Society of Nuclear Cardiology.
引用
收藏
页码:251 / 260
页数:9
相关论文
共 50 条
  • [31] [I-123] BETA-CIT SPECT IMAGING OF THE DOPAMINE TRANSPORTER IN PARKINSONISM
    MAREK, K
    SEIBYL, JP
    FUSSELL, B
    SMITH, ED
    BALDWIN, RM
    HOFFER, PB
    INNIS, RB
    [J]. NEUROLOGY, 1995, 45 (04) : A219 - A220
  • [32] SPECT PERFUSION IMAGING WITH I-123 HIPDM IN A PATIENT WITH PULMONARY-EMBOLISM
    PETRUZZELLI, S
    PALLA, A
    PREDILETTO, R
    MAZZUCA, N
    PISTOLESI, M
    GIUNTINI, C
    [J]. JOURNAL OF NUCLEAR MEDICINE AND ALLIED SCIENCES, 1989, 33 (01): : 45 - 48
  • [33] Initial experience with I-123 Ioflupane: Optimization of imaging protocol on SPECT/CT
    Khandekar, Shashi
    DiFilippo, Frank
    Amin, Kanak
    Brunken, Richard
    Neumann, Donald
    Wu, Guiyun
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [34] DETECTION OF MYOCARDIAL VIABILITY USING DYNAMIC SPECT I-123 IPPA IMAGING
    WOLMER, I
    POWERS, J
    SUNG, KK
    CAVE, V
    WASSERLEBEN, V
    CASSEL, D
    HEO, J
    ISKANDRIAN, AS
    [J]. CIRCULATION, 1993, 88 (04) : 200 - 200
  • [35] COLLIMATOR CHOICE FOR DIFFERENTIAL UPTAKE MEASUREMENTS USING SPECT IMAGING WITH I-123
    CLARKE, LP
    VAUGHAN, S
    HOURANI, M
    SERAFINI, A
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1983, 24 (05) : P75 - P75
  • [36] SPECT IMAGING WITH I-123 ISOPROPYL AMPHETAMINE IN ASYMPTOMATIC HIV SEROPOSITIVE PERSONS
    LAFRANCE, ND
    PEARLSON, G
    SCHAERF, F
    MCARTHUR, J
    BASCOM, MJ
    KUMAR, AJ
    TUREK, J
    COLE, P
    CHEN, J
    WAGNER, HN
    [J]. CLINICAL NUCLEAR MEDICINE, 1988, 13 (05) : 393 - 393
  • [37] BRAIN IMAGING WITH I-123 IMP-SPECT IN MIGRAINE BETWEEN ATTACKS
    SCHLAKE, HP
    BOTTGER, IG
    GROTEMEYER, KH
    HUSSTEDT, IW
    [J]. HEADACHE, 1989, 29 (06): : 344 - 349
  • [38] FUNCTIONAL IMAGING OF BRAIN MATURATION IN HUMANS USING I-123 IODOAMPHETAMINE AND SPECT
    RUBINSTEIN, M
    DENAYS, R
    HAM, HR
    PIEPSZ, A
    VANPACHTERBEKE, T
    HAUMONT, D
    NOEL, P
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1989, 30 (12) : 1982 - 1985
  • [39] I-123 MIBG SPECT/CT Hybrid Imaging in Evaluation of Neuroectodermal Tumors
    Vatankulu, B.
    Bozkurt, M. F.
    Ugur, O.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S379 - S379
  • [40] Benzodiazepine receptor imaging using [I-123] iomazenil SPECT in schizophrenia.
    Verhoeff, NPLG
    Soares, JC
    D'Souza, CD
    Gil, R
    Degen, K
    Wexler, B
    Abi-Dargham, A
    Baldwin, RM
    Zoghbi, SS
    Fujita, M
    Rajeevan, N
    Seibyl, JP
    Krystal, JH
    Innis, RB
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 82P - 82P