The Search Coil Magnetometer for THEMIS

被引:0
|
作者
A. Roux
O. Le Contel
C. Coillot
A. Bouabdellah
B. de la Porte
D. Alison
S. Ruocco
M. C. Vassal
机构
[1] Centre d’étude des Environnements Terrestre et Planétaires (CETP),
[2] 3D Plus,undefined
来源
Space Science Reviews | 2008年 / 141卷
关键词
Search-coil magnetometer; Magnetospheric mission; Substorm physics;
D O I
暂无
中图分类号
学科分类号
摘要
THEMIS instruments incorporate a tri-axial Search Coil Magnetometer (SCM) designed to measure the magnetic components of waves associated with substorm breakup and expansion. The three search coil antennas cover the same frequency bandwidth, from 0.1 Hz to 4 kHz, in the ULF/ELF frequency range. They extend, with appropriate Noise Equivalent Magnetic Induction (NEMI) and sufficient overlap, the measurements of the fluxgate magnetometers. The NEMI of the searchcoil antennas and associated pre-amplifiers is smaller than 0.76 pT \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$/\sqrt{\mathrm{Hz}}$\end{document} at 10 Hz. The analog signals produced by the searchcoils and associated preamplifiers are digitized and processed inside the Digital Field Box (DFB) and the Instrument Data Processing Unit (IDPU), together with data from the Electric Field Instrument (EFI). Searchcoil telemetry includes waveform transmission, FFT processed data, and data from a filter bank. The frequency range covered depends on the available telemetry. The searchcoils and their three axis structures have been precisely calibrated in a calibration facility, and the calibration of the transfer function is checked on board, usually once per orbit. The tri-axial searchcoils implemented on the five THEMIS spacecraft are working nominally.
引用
收藏
页码:265 / 275
页数:10
相关论文
共 50 条
  • [1] The Search Coil Magnetometer for THEMIS
    Roux, A.
    Le Contel, O.
    Coillot, C.
    Bouabdellah, A.
    de la Porte, B.
    Alison, D.
    Ruocco, S.
    Vassal, M. C.
    SPACE SCIENCE REVIEWS, 2008, 141 (1-4) : 265 - 275
  • [2] First Results of the THEMIS Search Coil Magnetometers
    Le Contel, O.
    Roux, A.
    Robert, P.
    Coillot, C.
    Bouabdellah, A.
    de la Porte, B.
    Alison, D.
    Ruocco, S.
    Angelopoulos, V.
    Bromund, K.
    Chaston, C. C.
    Cully, C.
    Auster, H. U.
    Glassmeier, K. H.
    Baumjohann, W.
    Carlson, C. W.
    McFadden, J. P.
    Larson, D.
    SPACE SCIENCE REVIEWS, 2008, 141 (1-4) : 509 - 534
  • [3] First Results of the THEMIS Search Coil Magnetometers
    O. Le Contel
    A. Roux
    P. Robert
    C. Coillot
    A. Bouabdellah
    B. de la Porte
    D. Alison
    S. Ruocco
    V. Angelopoulos
    K. Bromund
    C. C. Chaston
    C. Cully
    H. U. Auster
    K. H. Glassmeier
    W. Baumjohann
    C. W. Carlson
    J. P. McFadden
    D. Larson
    Space Science Reviews, 2008, 141 : 509 - 534
  • [4] OGO SEARCH COIL MAGNETOMETER EXPERIMENTS
    FRANDSEN, AM
    HOLZER, RE
    SMITH, EJ
    IEEE TRANSACTIONS ON GEOSCIENCE ELECTRONICS, 1969, GE 7 (02): : 61 - &
  • [5] The Search-Coil Magnetometer for MMS
    Le Contel, O.
    Leroy, P.
    Roux, A.
    Coillot, C.
    Alison, D.
    Bouabdellah, A.
    Mirioni, L.
    Meslier, L.
    Galic, A.
    Vassal, M. C.
    Torbert, R. B.
    Needell, J.
    Rau, D.
    Dors, I.
    Ergun, R. E.
    Westfall, J.
    Summers, D.
    Wallace, J.
    Magnes, W.
    Valavanoglou, A.
    Olsson, G.
    Chutter, M.
    Macri, J.
    Myers, S.
    Turco, S.
    Nolin, J.
    Bodet, D.
    Rowe, K.
    Tanguy, M.
    de la Porte, B.
    SPACE SCIENCE REVIEWS, 2016, 199 (1-4) : 257 - 282
  • [6] The Search-Coil Magnetometer for MMS
    O. Le Contel
    P. Leroy
    A. Roux
    C. Coillot
    D. Alison
    A. Bouabdellah
    L. Mirioni
    L. Meslier
    A. Galic
    M. C. Vassal
    R. B. Torbert
    J. Needell
    D. Rau
    I. Dors
    R. E. Ergun
    J. Westfall
    D. Summers
    J. Wallace
    W. Magnes
    A. Valavanoglou
    G. Olsson
    M. Chutter
    J. Macri
    S. Myers
    S. Turco
    J. Nolin
    D. Bodet
    K. Rowe
    M. Tanguy
    B. de la Porte
    Space Science Reviews, 2016, 199 : 257 - 282
  • [7] The THEMIS Fluxgate Magnetometer
    H. U. Auster
    K. H. Glassmeier
    W. Magnes
    O. Aydogar
    W. Baumjohann
    D. Constantinescu
    D. Fischer
    K. H. Fornacon
    E. Georgescu
    P. Harvey
    O. Hillenmaier
    R. Kroth
    M. Ludlam
    Y. Narita
    R. Nakamura
    K. Okrafka
    F. Plaschke
    I. Richter
    H. Schwarzl
    B. Stoll
    A. Valavanoglou
    M. Wiedemann
    Space Science Reviews, 2008, 141 : 235 - 264
  • [8] The THEMIS Fluxgate Magnetometer
    Auster, H. U.
    Glassmeier, K. H.
    Magnes, W.
    Aydogar, O.
    Baumjohann, W.
    Constantinescu, D.
    Fischer, D.
    Fornacon, K. H.
    Georgescu, E.
    Harvey, P.
    Hillenmaier, O.
    Kroth, R.
    Ludlam, M.
    Narita, Y.
    Nakamura, R.
    Okrafka, K.
    Plaschke, F.
    Richter, I.
    Schwarzl, H.
    Stoll, B.
    Valavanoglou, A.
    Wiedemann, M.
    SPACE SCIENCE REVIEWS, 2008, 141 (1-4) : 235 - 264
  • [9] Research of core characteristics of search coil magnetometer
    Yu, Qun
    Zhang, Houbo
    Lin, Guannan
    AUTOMATION EQUIPMENT AND SYSTEMS, PTS 1-4, 2012, 468-471 : 2820 - +
  • [10] Construction of Differential Type Search Coil Magnetometer
    Kim, J. H.
    Son, Derac
    JOURNAL OF THE KOREAN MAGNETICS SOCIETY, 2010, 20 (05): : 178 - 181