Determination of trace elements in zeolites by laser ablation ICP-MS

被引:0
|
作者
C. Pickhardt
I. B. Brenner
J. S. Becker
H.-J. Dietze
机构
[1] Zentralabteilung für Chemische Analysen,
[2] Forschungszentrum Jülich GmbH,undefined
[3] D-52425 Jülich,undefined
[4] Germany,undefined
[5] 9 Dishon Street,undefined
[6] Malkha BGU-EAL,undefined
[7] 96956 Jerusalem,undefined
[8] Israel,undefined
关键词
Zeolite; Inductively Couple Plasma Mass Spectrometry; Laser Ablation; Aluminosilicate; Trace Element Concentration;
D O I
暂无
中图分类号
学科分类号
摘要
Laser ablation inductively coupled plasma mass spectrometry using a quadrupole-based mass spectrometer (LA-ICP-QMS) was applied for the analysis of powdered zeolites (microporous aluminosilicates) used for clean-up procedures. For the quantitative determination of trace element concentrations three geological reference materials, granite NIM-G, lujavrite NIM-L and syenite NIM-S, from the National Institute for Metallurgy (South Africa) with a matrix composition corresponding to the zeolites were employed. Both the zeolites and reference materials were fused with a lithium borate mixture to increase the homogeneity and to eliminate mineralogical effects. In order to compare two different approaches for the quantification of analytical results in LA-ICP-MS relative sensitivity coefficients (RSCs) of chemical elements and calibration curves were measured using the geostandards. The experimentally obtained RSCs are in the range of 0.2-6 for all elements of interest. Calibration curves for trace elements were measured without and with Li or Ti as internal standard element. With a few exceptions the regression coefficients of the calibration curves are better than 0.993 with internal standardization. NIM-G granite reference material was employed to evaluate the accuracy of the technique. Therefore, the measured concentrations were corrected with RSCs which were determined using lujavrite reference material NIM-L. This quantification method provided analytical results with deviations of 1–11% from the recommended and proposed values in granite reference material NIM-G, except for Co, Cs, La and Tb. The relative standard deviation (RSD) of the determination of the trace element concentration (n = 5) is about 1% to 6% using Ti as internal standard element. Detection limits of LA-ICP-QMS in the lower μg/g range (from 0.03 μg/g for Lu, Ta and Th to 7.3 μg/g for Cu, with the exception of La) have been achieved for all elements of interest. Under the laser ablation conditions employed (λ: 266 nm, repetition frequency: 10 Hz, pulse energy: 10 mJ, laser power density: 6 × 109 W/cm2) fractionation effects of the determined elements relative to the internal standard element Ti were not observed.
引用
收藏
页码:79 / 87
页数:8
相关论文
共 50 条
  • [21] ICP-MS utilization for some trace elements determination in marine samples
    Chirila, Elisabeta
    Petisleam, Turchean
    Popovici, Ionela Carazeanu
    Caradima, Zoe
    REVISTA DE CHIMIE, 2006, 57 (08): : 803 - 807
  • [22] Study on the Determination of Trace Composition and Impurity Elements in Kaolin with ICP-MS
    Huang Dong-gen
    Zhou Wen-bin
    Liu Lei
    Quan Shui-qing
    He Zong-jian
    Wan Jin-bao
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (02) : 504 - 508
  • [23] Determination of trace elements in copper-zinc alloy by ICP-MS
    Hu, Jing-Yu
    Wang, Hai-Zhou
    Yejin Fenxi/Metallurgical Analysis, 2004, 24 (06):
  • [24] DETERMINATION OF TRACE ELEMENTS IN HUANGLONG TRAVERTINE AND EVALUATION OF UNCERTAINTY BY ICP-MS
    Gao, Wenhao
    Liu, Xinze
    Zhao, Songjiang
    Zeng, Ying
    FRESENIUS ENVIRONMENTAL BULLETIN, 2022, 31 (08): : 8057 - 8067
  • [25] Determination of trace elements in illicit spice samples by using ICP-MS
    Bora, Taner
    Aksoy, Cagdas
    Tunay, Zeki
    Aydin, Firat
    MICROCHEMICAL JOURNAL, 2015, 123 : 179 - 184
  • [26] Determination of Trace Elements in Edible Nuts in the Beijing Market by ICP-MS
    YIN Liang Liang
    TIAN Qing
    SHAO Xian Zhang
    KONG Xiang Yin
    JI Yan Qin
    BiomedicalandEnvironmentalSciences, 2015, 28 (06) : 449 - 454
  • [27] Determination of Trace Elements in Tobaccos by Microwave Digestion/ICP-MS Method
    Sun Yu-an
    Song Shi-qiu
    Wang Guo-qing
    Wei Li-fang
    Li Zhen-xing
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (07) : 1968 - 1971
  • [28] Determination of 20 Trace Elements in the Blood Collection Tubes with ICP-MS
    Xiong Chan
    Jiang, Xue-hui
    Tian Ya-ping
    Ma Qing-wei
    Liu Li-peng
    Guo Guang-hong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36 (11) : 3676 - 3682
  • [29] Measurement of trace elements in bone by ICP-MS
    Jensen, JEB
    Larsen, MM
    Kringsholm, B
    Pritzl, G
    Sorensen, OH
    THERAPEUTICS USES OF TRACE ELEMENTS, 1996, : 297 - 301
  • [30] Determination of selenium in the commercially bottled drinking water by ICP-MS - Determination of trace elements in environmental samples by ICP-MS .4.
    Naohara, J
    Yamashita, E
    JOURNAL OF THE JAPANESE SOCIETY FOR FOOD SCIENCE AND TECHNOLOGY-NIPPON SHOKUHIN KAGAKU KOGAKU KAISHI, 1996, 43 (10): : 1133 - 1137