Effect of Ribs Configurations on Heat Transfer Enhancement for W-Shaped Ribs in a Square Duct

被引:0
|
作者
Sameer Sheshrao Gajghate
Onkar Prakash Deshpande
Amit Uttam Desai
Akshay Dilip Deshmukh
Shrikant Uttam Kharade
Sagnik Pal
Elaine Maria Cardoso
Bidyut Baran Saha
Swapan Bhaumik
机构
[1] G H Raisoni College of Engineering and Management,Mechanical Engineering Department
[2] AGTI’s Dr. Daulatrao Aher College of Engineering Karad,Mechanical Engineering Department
[3] National Institute of Technology Agartala,Mechanical Engineering
[4] UNESP - São Paulo State University,International Institute for Carbon
[5] UNESP - São Paulo State University,Neutral Energy Research (WPI
[6] Kyushu University,I2CNER)
[7] Kyushu University,Mechanical Engineering Department
关键词
W-shaped rib turbulator; Area-averaged heat transfer enhancement; Reynolds number; Friction factor; Rib angle; Pitch ratio;
D O I
暂无
中图分类号
学科分类号
摘要
In this research, three W-shaped ribs are taken to analyze their influence on the heat transfer rate in the internal cooling of a gas turbine blade at constant e/Dh (0.037) and heat flux. The ribs are located on rectangular channels in a square duct, and the experiments are conducted for low Reynolds numbers (12,000–20,000). The influence of Reynolds number, pitch ratios (4.28, 5.71, and 7.14), rib shape, and rib angle (45°, 50°, and 55°) on the area-averaged heat transfer, friction factor, and thermal performance is analyzed. The experimental values of the Nusselt number and friction factor obtained from the smooth channel fit well with Dittus–Boelter and Blasius correlations. The Nusselt number increases with an increase in pitch ratio. The friction factor decreases by 3.5, 5.3, and 7.1 times for the W rib turbulator as the rib angle increases compared with the smooth channel. The present work reveals higher thermal performance than other studies based on ribs dimension, shape, pressure drop, frictional losses, and Reynolds number (12,000–20,000). Accordingly, using these geometric parameters, a new correlation of Nusselt number and friction factor is developed and compared with the experimental results. The Nusselt number and friction factor deviation were ± 6% and ± 11%, respectively.
引用
收藏
页码:12141 / 12160
页数:19
相关论文
共 50 条
  • [41] Heat transfer enhancement in solar air heater duct with conical protrusion roughness ribs
    Alam, Tabish
    Kim, Man-Hoe
    APPLIED THERMAL ENGINEERING, 2017, 126 : 458 - 469
  • [42] HEAT TRANSFER AND FRICTION IN CIRCULAR DUCTS WITH SHAPED RIBS
    Bonanni, L.
    Da Soghe, R.
    Facchini, B.
    Micio, M.
    Pievaroli, M.
    Tarchi, L.
    Abba, L.
    Maritano, M.
    10TH EUROPEAN CONFERENCE ON TURBOMACHINERY: FLUID DYNAMICS AND THERMODYNAMICS, 2013,
  • [43] Assessment of heat transfer in a triangular duct with different configurations of ribs using computational fluid dynamics
    Hameed, Mohammed Hadi
    Mohammed, Hafidh Hassan
    OPEN ENGINEERING, 2024, 14 (01):
  • [44] Experimental investigations of heat transfer enhancement from rectangular duct roughened by hybrid ribs
    Alfarawi, S.
    Abdel-Moneim, S. A.
    Bodalal, A.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2017, 118 : 123 - 138
  • [45] Investigational analysis of roughened solar air heater channel having W-shaped ribs with symmetrical gaps along with staggered ribs
    Thakur, Sushant
    Thakur, N. S.
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2023, 45 (03) : 7389 - 7404
  • [46] EXPERIMENTAL INVESTIGATION ON HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF A STATIONARY SQUARE DUCT ROUGHENED BY V AND Lambda-SHAPED RIBS
    Shukla, Anand
    Chaube, Alok
    Gupta, Shailesh
    Sirsath, Arvind
    FRONTIERS IN HEAT AND MASS TRANSFER, 2014, 5
  • [47] Numerical heat transfer study of turbulent square-duct flow through inline V-shaped discrete ribs
    Promvonge, Pongjet
    Changcharoen, Wayo
    Kwankaomeng, Sutapat
    Thianpong, Chinaruk
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2011, 38 (10) : 1392 - 1399
  • [48] Numerical predictions of flow topology and heat transfer in a square duct with staggered V-ribs
    Boonloi, Amnart
    Jedsadaratanachai, Withada
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2022, 139
  • [49] Nonboiling Heat Transfer and Friction of Air/Water Mist Flow in a Square Duct With Orthogonal Ribs
    Huang, Yi-Hsuan
    Chen, Chiao-Hsin
    Liu, Yao-Hsien
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2017, 9 (04)
  • [50] Heat transfer enhancement in a converging passage with discrete ribs
    Hu, ZJ
    Shen, JU
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1996, 39 (08) : 1719 - 1727