A digital system for producing X-ray images with a high spatial resolution

被引:0
|
作者
N. K. Kononov
S. M. Ignatov
V. N. Potapov
V. G. Negorezov
机构
[1] Russian Research Centre Kurchatov Institute,Institute for Nuclear Research
[2] Russian Academy of Sciences,undefined
关键词
87.59.-e;
D O I
暂无
中图分类号
学科分类号
摘要
A system for detecting X-ray shadowgraphs with a high spatial resolution, in which a shadowgraph formed on a luminophor is transferred to a charge-coupled device (CCD) matrix by using an objective lens, is considered. The signal stored on the CCD matrix is read, converted, and transmitted to the computer for further processing and representation. A 25-lp/mm spatial resolution was obtained for a 10.8 × 10.8-mm input field of the system. The measurements were performed by using a tungsten-wire standard placed on the surface of the input field of the detecting system, when the anode voltage was 45 kV, the anode current was ∼2 mA, and the focal distance was 450 mm. It was shown that the 25-lp/mm spatial resolution is not limiting and that it is possible to attain a value of 40 lp/mm or higher.
引用
收藏
页码:739 / 741
页数:2
相关论文
共 50 条
  • [21] High Spatial Resolution X-Ray Spectroscopy of Cas A with Chandra
    Xue-Juan Yang~(1
    2 Department of Astronomy
    ChineseJournalofAstronomyandAstrophysics, 2008, (04) : 439 - 450
  • [22] X-ray characterization of Si microstructures with high spatial resolution
    Cedola, A. (cedola@inf.cnr.it), 1662, American Institute of Physics Inc. (95):
  • [23] High Spatial Resolution X-Ray Mapping of CdZnTe detectors
    Yang, G.
    Bolotnikov, A. E.
    Camarda, G. S.
    Cui, Y.
    Hossain, A.
    James, R. B.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS X, 2008, 7079
  • [24] High spatial resolution X-ray beam position monitor
    Kocsis, M.
    Fajardo, P.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1223 - 1225
  • [25] X-ray characterization of Si microstructures with high spatial resolution
    Cedola, A
    Lagomarsino, S
    Scarinci, F
    Servidori, M
    Stanic, V
    JOURNAL OF APPLIED PHYSICS, 2004, 95 (04) : 1662 - 1666
  • [26] High spatial resolution x-ray luminescence computed tomography and x-ray fluorescence computed tomography
    Dai, Xianjin
    Sivasubramanian, Kathyayini
    Xing, Lei
    MOLECULAR-GUIDED SURGERY: MOLECULES, DEVICES, AND APPLICATIONS V, 2019, 10862
  • [27] X-ray tube focal spot size, digital detectors, imaging system aperture and spatial resolution
    Nickoloff, Edward L.
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [28] The x-ray light valve: A low-cost, digital radiographic imaging system - Spatial resolution
    MacDougall, Robert D.
    Koprinarov, Ivaylo
    Rowlands, J. A.
    MEDICAL PHYSICS, 2008, 35 (09) : 4216 - 4227
  • [29] A DIGITAL IMAGE-PROCESSING SYSTEM FOR HIGH-ENERGY X-RAY PORTAL IMAGES
    LEONG, J
    PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (12): : 1527 - 1535
  • [30] HIGH-RESOLUTION X-RAY IMAGES OF THE CRAB AND VELA PULSARS
    HARNDEN, FR
    HERTZ, P
    GORENSTEIN, P
    GRINDLAY, J
    SCHREIER, E
    SEWARD, F
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1980, 25 (04): : 509 - 509