Estimation of blood glucose by non-invasive method using photoplethysmography

被引:0
|
作者
Shraddha Habbu
Manisha Dale
Rajesh Ghongade
机构
[1] AISSMS-Institute of Information Technology,Department of Electronics and Telecommunication
[2] Vishwakarma Institute of Information Technology,Department of Electronics and Telecommunication
[3] Modern Education Societies College of Engineering,Department of Electronics and Telecommunication
[4] Bharati Vidyapeeth’s Deemed University College of Engineering,Department of Electronics and Telecommunication
来源
Sādhanā | 2019年 / 44卷
关键词
Blood glucose measurement; non-invasive; blood glucose level (BGL); neural network; photoplethysmograph (PPG); single pulse analysis (SPA);
D O I
暂无
中图分类号
学科分类号
摘要
This paper presents a system which estimates blood glucose level (BGL) by non-invasive method using Photoplethysmography (PPG). Previous studies have shown better estimation of blood glucose level using an optical sensor. An optical sensor based data acquisition system is built and the PPG signal of the subjects is recorded. The main contribution of this paper is exploring various features of a PPG signal using Single Pulse Analysis technique for effective estimation of BGL values. A PPG data of 611 individuals is recorded over duration of 3 minutes each. BGL value estimation is performed using two types of feature sets, (i) Time and frequency domain features and (ii) Single Pulse Analysis (SPA). Neural network is trained using above mentioned proposed feature sets and BGL value estimation is performed. First we validate our methodology using the same features used by Monte Moreno in his earlier work. The experimentation is performed on our own dataset. We obtained comparable results of BGL value estimation as compared with Monte Moreno, with maximum R2 = 0.81. Further, BGL estimation using (i) Time and frequency domain features and (ii) Single Pulse Analysis (SPA) is performed and the resulting coefficient of determination (i.e., R2) obtained for reference vs. prediction are 0.84 and 0.91, respectively. Clarke Error Grid analysis for BGL estimation is clinically accepted, so we performed similar analysis. Using Time and frequency domain feature set, the distributions of data samples is obtained as 80.6% in class A and 17.4% in class B. 1% samples in zone C and Zone D. For Single Pulse Analysis technique (SPA) the distribution of data samples are 83% in class A and 17% in class B. The proposed features in SPA have shown significant improvement in R2 and Clarke Error grid analysis. SPA technique with the proposed feature set is a good choice for the implementation of system for measurement of non-invasive glucometer.
引用
收藏
相关论文
共 50 条
  • [31] Spectroscopic Non-Invasive Method For Monitoring Glucose Concentration In Human Blood
    Gurevich, B. S.
    Shapovalov, V. V.
    Dudnikov, S. Yu
    Zagorsky, I. G.
    RESEARCH JOURNAL OF PHARMACEUTICAL BIOLOGICAL AND CHEMICAL SCIENCES, 2018, 9 (06): : 1022 - 1025
  • [32] Non-invasive estimation of hemoglobin in blood using color analysis
    Srinivasan, K. S.
    Lakshmi, D.
    Ranganathan, H.
    Gunasekaran, N.
    2006 INTERNATIONAL CONFERENCE ON INDUSTRIAL AND INFORMATION SYSTEMS, VOLS 1 AND 2, 2006, : 547 - +
  • [33] Non-invasive hemoglobin level estimation using photoplethysmography with performance comparison of advanced ML algorithms
    Song, Yalin
    SIGNAL IMAGE AND VIDEO PROCESSING, 2025, 19 (06)
  • [34] Review of Photoplethysmography Based Non-invasive Continuous Blood Pressure Methods
    Tjahjadi, Hendrana
    Ramli, Kalamullah
    2017 15TH INTERNATIONAL CONFERENCE ON QUALITY IN RESEARCH (QIR) - INTERNATIONAL SYMPOSIUM ON ELECTRICAL AND COMPUTER ENGINEERING, 2017, : 173 - 178
  • [35] Non-invasive monitoring of gingival crevicular fluid for estimation of blood glucose level
    M. Yamaguchi
    Y. Kawabata
    S. Kambe
    K. W⇘rdell
    F. H. Nystrom
    K. Naitoh
    H. Yoshida
    Medical and Biological Engineering and Computing, 2004, 42 : 322 - 327
  • [36] Perioperative non-invasive haemodynamic optimisation using photoplethysmography: CON
    Fischer, Marc-Olivier
    Debroczi, Stephane
    Gerard, Jean-Louis
    Hanouz, Jean-Luc
    Buleon, Clement
    ANAESTHESIA CRITICAL CARE & PAIN MEDICINE, 2021, 40 (01)
  • [37] Non-invasive Blood Glucose Determination using Near Infrared LED in Diffused Reflectance Method
    Arefin, Mohammed Shahriar
    Khan, Adnan Hossain
    Islam, Rabiul
    2018 10TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (ICECE), 2018, : 93 - 96
  • [38] Non-invasive Blood Glucose Measurement System
    Deepthi, S.
    Valke, Nikita S.
    Parvathy, J. P.
    Sai, Anjaly Krishna
    Sajjan, Guttappa
    2019 5TH IEEE INTERNATIONAL WIE CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (WIECON-ECE 2019), 2019,
  • [39] A Non-Invasive Blood Glucose Monitoring Device
    Kassem, Abdallah
    Hamad, Mustapha
    Harbieh, George G.
    El Moucary, Chady
    2020 IEEE 5TH MIDDLE EAST AND AFRICA CONFERENCE ON BIOMEDICAL ENGINEERING (MECBME), 2020, : 150 - 153
  • [40] Design and Implementation of Non-invasive Continuous Blood Pressure Measurement and Monitoring System Using Photoplethysmography
    Islam, Md. Aminul
    Ahmad, Mohiuddin
    2018 10TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (ICECE), 2018, : 173 - 176