Estimation of the collection efficiency of the axial flow cyclone dust collector with the fixed guide vanes

被引:0
|
作者
Ogawa A. [1 ]
Iwanami T. [2 ]
Shono H. [2 ]
机构
[1] Department of Mechanical Engineering, College of Engineering, Nihon University T-963, Kooriyama-shi, Tokusada, Tamura-machi
关键词
Axial flow cyclone; Collection efficiency; Eddy kinematic viscosity; Finite difference method; Mechanically balanced particle; Particle size distribution; Tangential velocity;
D O I
10.1007/s11630-997-0017-2
中图分类号
学科分类号
摘要
In order to estimate the cut-size Xc and the mechanically balanced particles in the axial flow cyclone with the slit-separation method, the tangential velocity distributions were calculated by the finite difference method. In comparison of the calculated results of the total collection efficiency with the experimental results, the calculated results showed a little higher than the experimental results due to the re-entrainment of the collected particles by turbulence. The effect of the slit for promoting the collection efficiency was not recognized.
引用
收藏
页码:58 / 65
页数:7
相关论文
共 50 条
  • [31] Numerical simulation of water flow in an axial flow pump with adjustable guide vanes
    Qian, Zhongdong
    Wang, Yan
    Huai, Wenxin
    Lee, Youngho
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2010, 24 (04) : 971 - 976
  • [32] Simulation of flow inside an axial-flow pump with adjustable guide vanes
    Kochevsky, Alexey N.
    Kozlov, Stanislav N.
    Aye, Khin Maung
    Schelyaev, Alexander Y.
    Konshin, Vladimir N.
    Proceedings of the ASME Fluids Engineering Division Summer Conference - 2005, Vol 1, Pts A and B, 2005, : 1397 - 1404
  • [33] Experimental Study on Particle Collection Efficiency of Axial-flow Cyclone in Air Handling Unit
    Kim, Seyoung
    Kwon, Soon-Bark
    Park, Duck-Shin
    Cho, Youngmin
    Kim, Jinho
    Kim, Myungjoon
    Kim, Taesung
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2011, 27 (03) : 272 - 280
  • [34] An experimental investigation on pressure drop and collection efficiency of cyclone separator with different inlet vanes
    Zhao, F.
    Chen, Y. X.
    Liu, W. H.
    Xu, D. L.
    Proceedings of the 6th International Symposium on Cement & Concrete and CANMET/ACI International Symposium on Concrete Technology for Sustainable Development, Vols 1 and 2, 2006, : 145 - 150
  • [35] Application of combined scheme of twisting the dust-gas flow in cyclone dust collector
    Kuz'min, V.V.
    Markov, V.A.
    Khimicheskaya Promyshlennost', 2003, (08): : 12 - 15
  • [36] Distributions of the tangential velocities on the dust laden gas flow in the cylindrical cyclone dust collector
    Ogawa, Akira
    Seito, Osamu
    Nagabayashi, Hisao
    Particulate Science and Technology, 1988, 6 (01) : 17 - 28
  • [37] Effect of inlet guide vanes on the performance of small axial flow fan
    Yang Liu
    Zhe Lin
    Peifeng Lin
    Yingzi Jin
    Toshiaki Setoguchi
    Heuy Dong Kim
    Journal of Thermal Science, 2017, 26 : 504 - 513
  • [38] Simulation of cavitation performance of an axial flow pump with inlet guide vanes
    Feng, Weimin
    Cheng, Qian
    Guo, Zhiwei
    Qian, Zhongdong
    ADVANCES IN MECHANICAL ENGINEERING, 2016, 8 (06)
  • [39] Investigation of the aerodynamic noise in the axial flow fan with additional guide vanes
    Lu, Wencan
    Huazhong Ligong Daxue Xuebao/Journal Huazhong (Central China) University of Science and Technology, 1995, 23 (Suppl 1):
  • [40] Effect of Inlet Guide Vanes on the Performance of Small Axial Flow Fan
    Liu Yang
    Lin Zhe
    Lin Peifeng
    Jin Yingzi
    Setoguchi, Toshiaki
    Kim, Heuy Dong