Block and Graft Copolymers of Poly(ethylene glycol) and Poly(dimethylsiloxane) for Blood Contacting Biomedical Materials Applications

被引:0
|
作者
Harri J. Jukarainen
Stephen J. Clarson
Jukka V. Seppälä
Gregory S. Retzinger
Jarkko K. Ruohonen
机构
[1] University of Cincinnati,Department of Chemical and Materials Engineering and the Polymer Research Centre
[2] Helsinki University of Technology,Department of Chemical Engineering
[3] University of Cincinnati,Department of Pathology and Laboratory Medicine
来源
Silicon | 2012年 / 4卷
关键词
Poly(ethylene glycol); Poly(dimethylsiloxane); Polystyrene; Fibrinogen; Thrombin; Cardiovascular biomaterials; Blood contacting surfaces; Blood clotting; Hemocompatibility;
D O I
暂无
中图分类号
学科分类号
摘要
The incorporation of both hydrophobic and hydrophilic groups into a synthetic polymer is a potent way of controlling its surface and interfacial properties. With this end result in mind, we describe herein the synthesis and characterization of poly(dimethylsiloxane-b-ethyleneoxide) block copolymers (PDMS-b-PEO) and poly(dimethylsiloxane-g-ethyleneoxide) grafted copolymers (PDMS-g-PEO). These amphiphillic copolymers were also investigated as surface modifying agents for passifying hydrophobic polymer surfaces in blood contacting applications. Specifically, the various (PDMS-b-PEO) and (PDMS-g-PEO) copolymers were coated onto poly(styrene-divinylbenzene) microspheres by their physical adsorption from solution. These surfaces were then evaluated for blood contacting applications utilizing a fibrinogen and thrombin protocol. In particular, the binding of fibrinogen and the functionality of the surface bound fibrinogen on an otherwise hydrophobic surface (polystyrene) was investigated. As the conversion of fibrinogen to fibrin is facilitated by thrombin, the aggregation of the copolymer-coated hydrophobic microspheres was followed using an optical method after the sequential exposure of the microspheres to fibrinogen and then to thrombin. We were able to determine how the adsorbed copolymers affected the functionality of the bound fibrinogen at an interface. Our hypothesis is that the hydrophobic siloxane units of the copolymers will be in close proximity to the polystyrene surface and that the PEO will extend out from the surface and therefore render the synthetic polymer system hemocompatible. Following the fibrinogen and thrombin protocol and determining the fibrinogen-dependent aggregation, the results show that the PDMS-b-PEO copolymers (having a PEO content from 4.6 to 11.5 weight %) were similar in terms of particle aggregation when compared to the pure polystyrene microspheres (blank) or to the microspheres that were coated with a linear PDMS homopolymer. By comparison, the PDMS-g-PEO copolymers (having a PEO content from 58 to 80 weight %) were seen to reduce the fibrinogen functionality on the microsphere system surface. Thus the data indicate that the PDMS-g-PEO copolymers can behave like molecular brushes that are able to pacify the surface of the hydrophobic polystyrene microspheres. A somewhat unexpected observation was that for the copolymer system having a low PEO content the fibrinogen-dependent aggregation of the otherwise hydrophobic microspheres was observed to increase relative to the pure microspheres (blank). It is clear from the findings of this investigation that the surface packing and molecular orientation of both the adsorbed copolymer and also of the fibrinogen are important factors that govern the properties and applications of blood contacting biomaterials.
引用
收藏
页码:231 / 238
页数:7
相关论文
共 50 条
  • [31] Synthesis of poly(dimethylsiloxane-alt-ethylene glycol) for hydrogel applications
    Tapsak, Mark A.
    Thursby, Evan W.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 234
  • [32] Blood compatibility evaluations of poly(ethylene glycol)-poly(lactic acid) copolymers
    Li, Chenghua
    Ma, Chengyan
    Zhang, Yi
    Liu, Zonghua
    Xue, Wei
    JOURNAL OF BIOMATERIALS APPLICATIONS, 2016, 30 (10) : 1485 - 1493
  • [33] POLY(ALPHA-METHYLSTYRENE)-POLY(DIMETHYLSILOXANE) BLOCK COPOLYMERS
    NOSHAY, A
    MATZNER, M
    KAROLY, G
    STAMPA, GB
    JOURNAL OF APPLIED POLYMER SCIENCE, 1973, 17 (02) : 619 - 628
  • [34] POLY(ALPHA-METHYLSTYRENE)-POLY(DIMETHYLSILOXANE) BLOCK COPOLYMERS
    NOSHAY, A
    STAMPA, GB
    MATZNER, M
    KAROLY, G
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1972, : 46 - &
  • [35] Physico-chemical Properties of Poly(ethylene glycol)-block-polypeptide-graft-poly( ethylene glycol) Film Improved by Poly(propylene glycol)
    Zhu, Guo-Quan
    Wang, Fa-Gang
    Gao, Qiao-Chun
    Liu, Yu-Ying
    ASIAN JOURNAL OF CHEMISTRY, 2014, 26 (01) : 29 - 32
  • [36] Thermal behaviour of poly(ε-caprolactone)-poly(ethylene glycol)-poly(ε-caprolactone) tri-block copolymers
    J. H. An
    H. S. Kim
    D. J. Chung
    D. S. Lee
    Sanghyo Kim
    Journal of Materials Science, 2001, 36 : 715 - 722
  • [37] PROPERTIES OF EXTRUDED POLY(TETRAMETHYLENE OXIDE) POLYURETHANE BLOCK COPOLYMERS FOR BLOOD-CONTACTING APPLICATIONS
    GRASEL, TG
    PITT, WG
    MURTHY, KD
    MCCOY, TJ
    COOPER, SL
    BIOMATERIALS, 1987, 8 (05) : 329 - 340
  • [38] Thermal behaviour of poly(ε-caprolactone)-poly(ethylene glycol)-poly(ε-caprolactone) tri-block copolymers
    An, JH
    Kim, HS
    Chung, DJ
    Lee, DS
    Kim, S
    JOURNAL OF MATERIALS SCIENCE, 2001, 36 (03) : 715 - 722
  • [39] Thin films of poly(dimethylsiloxane) block copolymers
    Cavicchi, Kevin A.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 237
  • [40] GRGDS-functionalized poly(lactide)-graft-poly(ethylene glycol) copolymers for bone-grafting applications
    Borchmann, Dorothee E.
    Avendano, Sarha
    Weck, Marcus
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 247