On-line monitoring of phosphate in natural water and effluent streams using sequential injection analysis

被引:0
|
作者
Jacobus Frederick van Staden
Rosa Elizabeth Taljaard
机构
[1] University of Pretoria,Department of Chemistry
来源
Microchimica Acta | 1998年 / 128卷
关键词
phosphate; water; sequential injection; spectrophotometry; molybdenum blue;
D O I
暂无
中图分类号
学科分类号
摘要
Automation of the molybdenum blue method by sequential injection (SIA) for the on-line monitoring of phosphate in natural waters is presented. Although sequential injection analysis runs at one fifth the speed of conventional FIA, it presents many advantages such as simplicity of the manifold, robustness and computer compatibility. A reduction in reagent and sample consumption is also observed. Flow detector fouling does not occur in SIA manifolds as the detector is in contact with water between analysis. The proposed SIA analyser is able to monitor phosphate in the range 0–70 mg l−1 with a standard deviation of 0.9%. The detection limit is 0.5 mg l−1 PO43−.
引用
收藏
页码:223 / 228
页数:5
相关论文
共 50 条
  • [31] A sonoluminescent method for on-line monitoring of the natural water quality
    Worontsov, A. M.
    Patsovskii, A. P.
    Nikanorova, M. N.
    Krivtsova, G. B.
    RUSSIAN JOURNAL OF APPLIED CHEMISTRY, 2008, 81 (01) : 55 - 60
  • [32] On-line analysis of mercury by sequential injection stripping analysis (SISA) using a chemically modified electrode
    Turyan, I
    Erichsen, T
    Schuhmann, W
    Mandler, D
    ELECTROANALYSIS, 2001, 13 (01) : 79 - 82
  • [33] Development of hardware and software for on-line sample preparation using sequential-injection analysis
    Neira, J.Y.
    Reyes, N.
    Nóbrega, J.A.
    1600, John Wiley & Sons Inc, New York, NY, United States (12):
  • [34] Development of hardware and software for on-line sample preparation using sequential-injection analysis
    Neira, JY
    Reyes, N
    Nóbrega, JA
    LABORATORY ROBOTICS AND AUTOMATION, 2000, 12 (05) : 246 - 252
  • [35] On-line monitoring amplification of bromate in bottled ozonated water by flow injection analysis and spectrophotometry
    Othman, Razhan S.
    Faizullah, Azad T.
    INORGANIC CHEMISTRY COMMUNICATIONS, 2022, 142
  • [36] On-line monitoring of the methanol concentration in Pichia pastoris cultures producing an heterologous lipase by sequential injection analysis
    Surribas, A
    Cos, O
    Montesinos, JL
    Valero, F
    BIOTECHNOLOGY LETTERS, 2003, 25 (21) : 1795 - 1800
  • [37] On-line monitoring of the methanol concentration in Pichia pastoris cultures producing an heterologous lipase by sequential injection analysis
    A. Surribas
    O. Cos
    J.L. Montesinos
    F. Valero
    Biotechnology Letters, 2003, 25 : 1795 - 1800
  • [38] On-line monitoring of spent fuel reprocessing streams
    Levitskaia, Tatiana G.
    Billing, Justin M.
    Bryan, Samuel A.
    Casella, Amanda J.
    Jonsen, Amanda M.
    Lines, Amanda M.
    Lines, Amanda M.
    Peterson, James M.
    Thomas, Elisabeth M.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 239
  • [39] On-line monitoring of chlorosilane streams by Raman spectroscopy
    Lipp, ED
    Grosse, RL
    APPLIED SPECTROSCOPY, 1998, 52 (01) : 42 - 46
  • [40] On-line monitoring of spent fuel reprocessing streams
    Bryan, Samuel A.
    Levitskaia, Tatiana G.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 242