Calibration of the spectral sensitivity of instruments for the near infrared region

被引:0
|
作者
P. S. Parfenov
A. P. Litvin
A. V. Baranov
A. V. Veniaminov
E. V. Ushakova
机构
[1] St. Petersburg State University of Information Technologies,
[2] Mechanics,undefined
[3] and Optics,undefined
来源
关键词
near infrared range; quantum dots; luminescence; spectroscopy; calibration;
D O I
暂无
中图分类号
学科分类号
摘要
We present an analysis of methods for calibration of the spectral sensitivity of instruments in the near IR region of the spectrum (0.90–2.05 μm), using as an example recording of the luminescence spectra of PbS semiconductor quantum dots using a diffraction monochromator and an InGaAs photodiode as the detector. We show that when high-sensitivity detectors are employed for calibration using the emission spectrum of an ideal black body, the problem of attenuation of the radiation flux is still important. Instead of neutral density glass and mesh light filters for attenuation of the radiation, we propose using UFS ultraviolet optical glasses (together with PS purple glasses), the maximum optical density of which is within the region of maximum spectral sensitivity of InGaAs photodiodes. We give examples of spectral calibration, taking into account instrumental characteristics and the effect of absorption by water vapor in the air, and also corrections of the luminescence spectra of quantum dots.
引用
收藏
页码:433 / 439
页数:6
相关论文
共 50 条
  • [21] Sensitivity of near infrared total water vapour estimate to calibration errors
    Chylek, P
    Clodius, WB
    Bender, SC
    Atkins, WH
    Balick, LK
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 2004, 25 (21) : 4457 - 4470
  • [22] COMPARISON OF SPECTRAL RESPONSE OF NEAR-INFRARED SPECTROMETERS USED FOR ROUTINE ANALYSES .2. STUDY OF THE TRANSFER OF CALIBRATION BETWEEN INSTRUMENTS
    DESAINTDO, I
    BERTRAND, D
    ANALUSIS, 1990, 18 (03) : 157 - 161
  • [23] THERMOMECHANICAL SENSITIVITY OF MICROCANTILEVERS IN THE MID-INFRARED SPECTRAL REGION
    Kwon, B.
    Wang, C.
    Park, K.
    Bhargava, R.
    King, W. P.
    NANOSCALE AND MICROSCALE THERMOPHYSICAL ENGINEERING, 2011, 15 (01) : 16 - 27
  • [24] Design of antireflection wideband coatings for the near infrared spectral region
    Pencheva, TG
    Nenkov, MR
    Gyoch, BS
    2005 28TH INTERNATIONAL SPRING SEMINAR ON ELECTRONICS TECHNOLOGY, 2005, : 106 - 111
  • [25] Tapping the near-infrared spectral region with bacteriochlorin arrays
    Lindsey, Jonathan S.
    Mass, Olga
    Chen, Chih-Yuan
    NEW JOURNAL OF CHEMISTRY, 2011, 35 (03) : 511 - 516
  • [26] Improving calibration transfer between shortwave near infrared silicon photodiode array instruments
    Hayes, Clinton J.
    Walsh, Kerry B.
    Greensill, Colin V.
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2016, 24 (01) : 59 - 68
  • [27] Optical design and spectral calibration of the visible-near infrared irradiance monitor
    Huang, Xionghao
    Zheng, Xiaobing
    Xie, Junfeng
    Mo, Fan
    Pan, Yang
    Huang, Ziju
    Wei, Wei
    Kang, Qing
    Xu, Chaopeng
    Tang, Hongzhao
    Tang, Xinming
    OPTICAL ENGINEERING, 2024, 63 (06)
  • [28] The Effect of MSC Spectral Pretreatment Regions on Near Infrared Spectroscopy Calibration Results
    Wang Dong-min
    Ji Jun-min
    Gao Hong-zhi
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (09) : 2387 - 2390
  • [29] A Hybrid Multivariate Calibration Optimization Method for Visible Near Infrared Spectral Analysis
    Li, Lina
    Li, Dengshan
    PROCEEDINGS OF 2021 7TH INTERNATIONAL CONFERENCE ON CONDITION MONITORING OF MACHINERY IN NON-STATIONARY OPERATIONS (CMMNO), 2021, : 76 - 81
  • [30] Spectral Encoder to Extract the Features of Near-Infrared Spectra for Multivariate Calibration
    Duan, Chaoshu
    Liu, Xuyang
    Cai, Wensheng
    Shao, Xueguang
    JOURNAL OF CHEMICAL INFORMATION AND MODELING, 2022, 62 (16) : 3695 - 3703