Calibration of the spectral sensitivity of instruments for the near infrared region

被引:0
|
作者
P. S. Parfenov
A. P. Litvin
A. V. Baranov
A. V. Veniaminov
E. V. Ushakova
机构
[1] St. Petersburg State University of Information Technologies,
[2] Mechanics,undefined
[3] and Optics,undefined
来源
关键词
near infrared range; quantum dots; luminescence; spectroscopy; calibration;
D O I
暂无
中图分类号
学科分类号
摘要
We present an analysis of methods for calibration of the spectral sensitivity of instruments in the near IR region of the spectrum (0.90–2.05 μm), using as an example recording of the luminescence spectra of PbS semiconductor quantum dots using a diffraction monochromator and an InGaAs photodiode as the detector. We show that when high-sensitivity detectors are employed for calibration using the emission spectrum of an ideal black body, the problem of attenuation of the radiation flux is still important. Instead of neutral density glass and mesh light filters for attenuation of the radiation, we propose using UFS ultraviolet optical glasses (together with PS purple glasses), the maximum optical density of which is within the region of maximum spectral sensitivity of InGaAs photodiodes. We give examples of spectral calibration, taking into account instrumental characteristics and the effect of absorption by water vapor in the air, and also corrections of the luminescence spectra of quantum dots.
引用
收藏
页码:433 / 439
页数:6
相关论文
共 50 条
  • [1] CALIBRATION OF THE SPECTRAL SENSITIVITY OF INSTRUMENTS FOR THE NEAR INFRARED REGION
    Parfenov, P. S.
    Litvin, A. P.
    Baranov, A. V.
    Veniaminov, A. V.
    Ushakova, E. V.
    JOURNAL OF APPLIED SPECTROSCOPY, 2011, 78 (03) : 433 - 439
  • [2] Standardisation and calibration transfer for near infrared instruments: a review
    Fearn, T
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2001, 9 (04) : 229 - 244
  • [3] CALIBRATION OF POWER AND ENERGY METERS FOR THE FAR INFRARED NEAR MILLIMETER WAVE SPECTRAL REGION
    FOOTE, FB
    HODGES, DT
    DYSON, HB
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 1981, 2 (04): : 773 - 782
  • [4] AN UPDATE ON VISIBLE AND NEAR-INFRARED CALIBRATION OF SATELLITE INSTRUMENTS
    PRICE, JC
    REMOTE SENSING OF ENVIRONMENT, 1988, 24 (03) : 419 - 422
  • [5] Prismatic imaging polarimeter calibration for the infrared spectral region
    Kudenov, Michael W.
    Pezzaniti, Larry
    Dereniak, Eustace L.
    Gerhart, Grant R.
    OPTICS EXPRESS, 2008, 16 (18) : 13720 - 13737
  • [6] Multivariate sensitivity for the interpretation of the effect of spectral pretreatment methods on near-infrared calibration model predictions
    Faber, NM
    ANALYTICAL CHEMISTRY, 1999, 71 (03) : 557 - 565
  • [7] CALIBRATION IN THE FIBER OPTIC REGION OF THE NEAR-INFRARED
    TENGE, B
    BUCHANAN, BR
    HONIGS, DE
    APPLIED SPECTROSCOPY, 1987, 41 (05) : 779 - 785
  • [8] Calibration of high resolution remote sensing instruments in the visible and near infrared
    Schuller, L
    Fischer, J
    Armbruster, W
    Bartsch, B
    CALIBRATION AND INTERCALIBRATION OF SATELLITE SENSORS AND EARLY RESULTS OF RADARSAT, 1997, 19 (09): : 1325 - 1334
  • [9] A data-driven near infrared calibration process including near infrared spectral thumbprints
    Nielsen, Sharon
    Russell, Kenneth G.
    Kelly, Alison
    Fox, Glen
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2018, 26 (03) : 169 - 185
  • [10] Near-infrared calibration transfer based on spectral regression
    Peng, Jiangtao
    Peng, Silong
    Jiang, An
    Tan, Jie
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2011, 78 (04) : 1315 - 1320