Characterization of a solventless injection interface for supercritical fluid chromatography

被引:0
|
作者
J. Y. Gao
C. E. Kibbey
机构
[1] Division of Warner-Lambert Company,Parke
来源
Chromatographia | 2000年 / 51卷
关键词
Supercritical fluid chromatography; Solventless injection; Solvent-induced band broadening;
D O I
暂无
中图分类号
学科分类号
摘要
Packed column supercritical fluid chromatography (SFC) is capable of highly efficient separations of drug-like molecules with les solvent consumption than HPLC. However, solute peaks in SFC are susceptible to broadening and distortion due to mismatch between the elution strength and viscosity of the injection solvent and the SFC mobile phase. The magnitude of solvent-induced band broadening increases as the elution strength and viscosity of the sample and mobile phase become more dissimilar and varies with the type of stationary phase used and the nature of the solute injected. A number of researchers have coupled supercritical fluid extraction with supercritical fluid chromatography in an attempt to remove solvent from injected samples, and thereby reduce peak broadening and distortion during SFC chromatography. While solventless injection is effective in overcoming solvent-induced band broadening in SFC, there have been few reports dealing with the optimization of the solvent removal process of this technique. In this work, we describe the influence of temperature, purge time, purging gas flow rate, stationary phase used in the sample precolumn, and injection solvent composition on solvent elimination and solute recovery.
引用
收藏
页码:747 / 755
页数:8
相关论文
共 50 条
  • [21] SUPERCRITICAL FLUID INJECTION OF POLYSILOXANE SOLUTIONS FOR CALIBRATION AND TUNING IN SUPERCRITICAL FLUID CHROMATOGRAPHY-MASS SPECTROMETRY
    PINKSTON, JD
    OWENS, GD
    PETIT, EJ
    ANALYTICAL CHEMISTRY, 1989, 61 (07) : 775 - 777
  • [22] Improved supercritical fluid chromatography ion mobility spectrometry interface
    Wu, C
    Siems, WF
    Hill, HH
    Hannan, RM
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1999, 11 (04) : 251 - 257
  • [23] Supercritical fluid chromatography and supercritical fluid extraction
    Poole, CF
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2000, 43 (1-3): : 1 - 2
  • [24] CHARACTERIZATION OF HEAVY OILS BY CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY
    FUHR, BJ
    HOLLOWAY, LR
    REICHERT, C
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 195 : 21 - PETR
  • [25] CHARACTERIZATION OF POLYMER ADDITIVES BY SUPERCRITICAL FLUID CHROMATOGRAPHY AND BY LIQUID-CHROMATOGRAPHY
    GREIBROKK, T
    BERG, BE
    HOFFMANN, S
    NORLI, HR
    YING, Q
    JOURNAL OF CHROMATOGRAPHY, 1990, 505 (01): : 283 - 291
  • [26] SUPERCRITICAL FLUID CHROMATOGRAPHY
    MOURIER, P
    SASSIAT, P
    CAUDE, M
    ROSSET, R
    ANALUSIS, 1984, 12 (05) : 229 - 248
  • [27] Supercritical fluid chromatography
    Taylor, Larry T.
    ANALYTICAL CHEMISTRY, 2008, 80 (12) : 4285 - 4294
  • [28] Supercritical fluid chromatography
    Parr, Maria Kristina
    Langley, G. John
    DRUG TESTING AND ANALYSIS, 2024, 16 (07) : 678 - 679
  • [29] SUPERCRITICAL FLUID CHROMATOGRAPHY
    CHESTER, TL
    PINKSTON, JD
    ANALYTICAL CHEMISTRY, 1990, 62 (12) : R394 - R402
  • [30] Large volume injection for packed column and capillary supercritical fluid chromatography
    Arnold, M
    Kleibohmer, W
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1995, 18 (11): : 721 - 724