Filter Backwash Water and Floated Residue Containing Pathogenic Protozoa: Detection Method and Treatment Alternatives

被引:0
|
作者
Hugo Guilherme Silva
Lyda Patricia Sabogal-Paz
机构
[1] University of São Paulo,Department of Hydraulics and Sanitation, São Carlos School of Engineering
来源
关键词
Ozone; Calcium oxide; Disinfection; Parasites; Sludge; Immunomagnetic separation;
D O I
暂无
中图分类号
学科分类号
摘要
Treatments using ozone for filter backwash water (FBW) and calcium oxide for floated residue (FR) were evaluated adopting bench-scale testing for the inactivation of Giardia spp. cysts and Cryptosporidium parvum oocysts. The protocol chosen for protozoa detection involved following the concentration step by direct centrifugation (adding ICN 7X cleaning solution at 1.0%) and purification by immunomagnetic separation (IMS). The FR treatment with calcium oxide (dosage of 23 mg CaO 100 mL−1 and 3-day contact time at 25 °C) proved to be efficient, as no parasites were detected after the treatment. The reduction of calcium oxide dosage (16 mg CaO 100 mL−1 and 3-day contact time at 25 °C) was insufficient to inactivate the protozoa, since potentially viable organisms were identified using propidium iodide (PI). Concerning the disinfection conditions with ozone (5-min and 10-min contact time and dosage of 10 mg O3 L−1 and 7.5 mg O3 L−1, respectively), there was complete removal of the target organisms, as no protozoa were detected after the FBW treatment. From the results obtained, the tested treatments can be considered promising alternatives for water treatment plants (WTPs). However, the costs incurred from these treatments have to be considered.
引用
收藏
相关论文
共 50 条
  • [1] Filter Backwash Water and Floated Residue Containing Pathogenic Protozoa: Detection Method and Treatment Alternatives
    Silva, Hugo Guilherme
    Sabogal-Paz, Lyda Patricia
    WATER AIR AND SOIL POLLUTION, 2020, 231 (03):
  • [2] Filter backwash water treatment options
    Arendze, S.
    Sibiya, M.
    JOURNAL OF WATER REUSE AND DESALINATION, 2014, 4 (02): : 85 - 91
  • [3] New method to evaluate backwash performance of rapid filter in water treatment facility
    Tsai, Hsien-Yi
    Wu, Chih-Chao
    Wan, Meng-Wei
    Kan, Chi-Chuan
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [4] Spent filter backwash water contaminants and treatment strategies
    Arora, H
    Di Giovanni, G
    LeChevallier, M
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2001, 93 (05): : 100 - +
  • [5] TREATMENT OF FILTER BACKWASH WATER IN A HOT-ROLLING MILL
    BOHNSTEDT, W
    STAHL UND EISEN, 1977, 97 (14): : 681 - 685
  • [6] Ultrafiltration for the reuse of spent filter backwash water from drinking water treatment
    Reissmann, Florian G.
    Uhl, Wolfgang
    DESALINATION, 2006, 198 (1-3) : 225 - 235
  • [7] Purposefulness of Recycling Rapid Filter Backwash Water in Surface Water Treatment Systems
    Zimoch, Izabela
    OCHRONA SRODOWISKA, 2013, 35 (04): : 17 - 22
  • [8] Detection of Cryptosporidium Parvum Oocysts in Artificially Contaminated Filter Backwash Water and Ozone Treatment at Pilot Scale
    Ogura, Allan Pretti
    Sabogal-Paz, Lyda Patricia
    OZONE-SCIENCE & ENGINEERING, 2022, 44 (05) : 426 - 437
  • [9] Treatment of spent filter backwash water from drinking water treatment with immersed ultrafiltration membranes
    Curko, Josip
    Mijatovic, Ivan
    Rumora, Dean
    Crnek, Vlado
    Matosic, Marin
    Nezic, Mladen
    DESALINATION AND WATER TREATMENT, 2013, 51 (25-27) : 4901 - 4906
  • [10] Assessment of pathogenic protozoa in a drinking water treatment plant with UV treatment
    Moreno-Mesonero, L.
    Soler, P.
    Alonso, J. L.
    Macian, V. J.
    Moreno, Y.
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2024, 366