Assessment of pathogenic protozoa in a drinking water treatment plant with UV treatment

被引:1
|
作者
Moreno-Mesonero, L. [1 ]
Soler, P. [1 ,2 ]
Alonso, J. L. [1 ]
Macian, V. J. [2 ]
Moreno, Y. [1 ]
机构
[1] Univ Politecn Valencia, Res Inst Water & Environm Engn IIAMA, Camino Vera S-N, Valencia 46022, Spain
[2] Empresa Mixta Valenciana Aguas SA EMIVASA, Ave Del Regne De Valencia 28, Valencia 46005, Spain
关键词
Pathogenic protozoa; Cryptosporidium; Giardia; Blastocystis; Amplicon sequencing; UV disinfection; CRYPTOSPORIDIUM OOCYSTS; GIARDIA CYSTS; COMMUNITIES; BACTERIA; INACTIVATION; DIVERSITY; TRANSMISSION; IRRADIATION; OUTBREAKS; PARASITES;
D O I
10.1016/j.jenvman.2024.121897
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Controlling drinking water treatment processes is essential to address water contamination and the adaptability of certain pathogenic protozoa. Sometimes, standard treatment methods and chlorine disinfection may prove insufficient in eliminating pathogenic protozoa. However, ultraviolet (UV) radiation has proved to be more effective than chlorine. This study aims to characterize the eukaryotic community of a drinking water treatment plant that applies a final UV disinfection treatment, focusing on pathogenic protozoa. Fifty water samples (raw water, before and after UV treatment) were evaluated to comply with regulation parameters and identify relevant protozoa. Despite physicochemical and microbiological parameters meeting the regulation, some potentially pathogenic protozoa, such as Blastocystis or Cryptosporidium, were still detected in very low relative abundances in treated water. It was found for the first time in Spain the pathogenic amoebae Naegleria fowleri in one river water, which was not found after the treatment. Moreover, Blastocystis subtypes ST1-ST6 were detected in this study in raw, before and after UV water samples. Blastocystis was only found in 2 two samples after UV treatment, with a very low abundance (<= 0.02%). Obtained results demonstrate the effectiveness of water treatment in reducing the prevalence of pathogenic protozoa.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] QMRA of adenovirus in drinking water at a drinking water treatment plant using UV and chlorine dioxide disinfection
    Schijven, Jack
    Teunis, Peter
    Suylen, Trudy
    Ketelaars, Henk
    Hornstra, Luc
    Rutjes, Saskia
    WATER RESEARCH, 2019, 158 : 34 - 45
  • [2] Reduction of Pathogenic and Indicator Viruses at a Drinking Water Treatment Plant in Southern Louisiana, USA
    Sarmila Tandukar
    Samendra P. Sherchan
    Eiji Haramoto
    Food and Environmental Virology, 2020, 12 : 269 - 273
  • [3] Reduction of Pathogenic and Indicator Viruses at a Drinking Water Treatment Plant in Southern Louisiana, USA
    Tandukar, Sarmila
    Sherchan, Samendra P.
    Haramoto, Eiji
    FOOD AND ENVIRONMENTAL VIROLOGY, 2020, 12 (03) : 269 - 273
  • [4] Genotoxicity and cytotoxicity assessment in lake drinking water produced in a treatment plant
    Buschini, A
    Carboni, P
    Frigerio, S
    Furlini, M
    Marabini, L
    Monarca, S
    Poli, P
    Radice, S
    Rossi, C
    MUTAGENESIS, 2004, 19 (05) : 341 - 347
  • [5] Bioanalytical Assessment of the Formation of Disinfection Byproducts in a Drinking Water Treatment Plant
    Neale, Peta A.
    Antony, Alice
    Bartkow, Michael E.
    Farre, Maria Jose
    Heitz, Anna
    Kristiana, Ina
    Tang, Janet Y. M.
    Escher, Beate I.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2012, 46 (18) : 10317 - 10325
  • [6] STUDIES ON OBTAINING OF DRINKING WATER QUALITY IN A DRINKING WATER TREATMENT PLANT
    Cical, Elena
    Mecea, Mircea
    Vatca, Gheorghe
    Mihali, Cristina
    Duteanu, Narcis
    CARPATHIAN JOURNAL OF FOOD SCIENCE AND TECHNOLOGY, 2011, 3 (01) : 1 - 6
  • [7] Raw water quality assessment for the treatment of drinking water
    Wang, Dongsheng
    ENVIRONMENTAL EARTH SCIENCES, 2016, 75 (19)
  • [8] Raw water quality assessment for the treatment of drinking water
    Dongsheng Wang
    Environmental Earth Sciences, 2016, 75
  • [9] Evaluation of turbidity as a parameter indicator of treatment in a drinking water treatment plant
    Rocio Martinez-Orjuela, Monica
    Yamid Mendoza-Coronado, Julian
    Eugenia Medrano-Solis, Beatriz
    Marina Gomez-Torres, Luisa
    Alfonso Zafra-Mejia, Carlos
    UIS INGENIERIAS, 2020, 19 (01): : 15 - 24
  • [10] Microbial Communities Shaped by Treatment Processes in a Drinking Water Treatment Plant and Their Contribution and Threat to Drinking Water Safety
    Li, Qi
    Yu, Shuili
    Li, Lei
    Liu, Guicai
    Gu, Zhengyang
    Liu, Minmin
    Liu, Zhiyuan
    Ye, Yubing
    Xia, Qing
    Ren, Liumo
    FRONTIERS IN MICROBIOLOGY, 2017, 8