Intensity modulated radiotherapy dosimetry with ion chambers, TLD, MOSFET and EDR2 film

被引:0
|
作者
R. A. Kinhikar
R. Upreti
S. Sharma
C. M. Tambe
D. D. Deshpande
机构
[1] Tata Memorial Hospital,Department of Medical Physics
关键词
IMRT; Ion chambers; TLD; MOSFET; EDR2 film;
D O I
暂无
中图分类号
学科分类号
摘要
Purpose of this study was to report in a together our experience of using ion chambers, TLD, MOSFET and EDR2 film for dosimetric verification of IMRT plans delivered with dynamic multileaf collimator (DMLC). Two ion chambers (0.6 and 0.13 CC) were used. All measurements were performed with a 6MV photon beam on a Varian Clinac 6EX LINAC equipped with a Millennium MLC. All measurements were additionally carried out with (LiF:Mg,TI) TLD chips. Five MOSFET detectors were also irradiated. EDR2 films were used to measure coronal planar dose for 10 patients. Measurements were carried out simultaneously for cumulative fields at central axis and at off-axis at isocenter plane (±1, and ±2cm). The mean percentage variation between measured cumulative central axis dose with 0.6 cc ion chamber and calculated dose with TPS was −1.4% (SD 3.2). The mean percentage variation between measured cumulative absolute central axis dose with 0.13 cc ion chamber and calculated dose with TPS was −0.6% (SD 1.9). The mean percentage variation between measured central axis dose with TLD and calculated dose with TPS was −1.8% (SD 2.9). A variation of less than 5% was found between measured off-axis doses with TLD and calculated dose with TPS. For all the cases, MOSFET agreed within ±5%. A good agreement was found between measured and calculated isodoses. Both ion chambers (0.6 CC and 0.13 CC) were found in good agreement with calculated dose with TPS.
引用
收藏
页码:25 / 32
页数:7
相关论文
共 50 条
  • [21] Comparison of gafchromic EBT film with EDR2 film in TomoTherapy delivery QA
    Jeong, K. K.
    Kim, Y. N.
    Kim, J. Y.
    MEDICAL PHYSICS, 2007, 34 (06) : 2429 - 2429
  • [22] The use of film dosimetry of the penumbra region to improve the accuracy of intensity modulated radiotherapy
    Arnfield, MR
    Otto, K
    Aroumougame, VR
    Alkins, RD
    MEDICAL PHYSICS, 2005, 32 (01) : 12 - 18
  • [23] RapidArc Delivery Performance Using EDR2 Film and EPID Measurement
    Xu, S.
    Ge, R.
    Xu, W.
    Cong, X.
    Xie, C.
    Gong, H.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [24] Intercomparison of EDR2 and high sensitivity radiochromic film for measuring small beams
    Zeidan, O
    Li, J
    Low, D
    Dempsey, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1397 - 1397
  • [25] Radiochromic film based transit dosimetry for verification of dose delivery with intensity modulated radiotherapy
    Chung, Kwangzoo
    Yoon, Myonggeun
    Son, Jaeman
    Park, Sung Yong
    Lee, Kiho
    Shin, Dongho
    Lim, Young Kyung
    Lee, Se Byeong
    MEDICAL PHYSICS, 2013, 40 (02)
  • [26] Radiochromic Film Based Transit Dosimetry for Verification of Dose Delivery with Intensity Modulated Radiotherapy
    Chung, K.
    Yoon, M.
    Son, J.
    Park, S.
    Lee, K.
    Shin, D.
    Lim, Y.
    Lee, S.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [27] Film dosimetry for intensity modulated radiation therapy
    Benites-Rengifo, J
    Martínez-Dávalos, A
    Celis, M
    Lárraga, J
    MEDICAL PHYSICS, 2004, 724 : 244 - 248
  • [28] The response of Kodak EDR2 film in high-energy electron beams
    Gerbi, BJ
    Dimitroyannis, DA
    MEDICAL PHYSICS, 2003, 30 (10) : 2703 - 2705
  • [29] The effect of ion chamber volume on intensity-modulated radiotherapy small field dosimetry
    Parlar, Sule
    Uzal, Cem
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2022, 15 (01) : 95 - 99
  • [30] Effect of processing time delay on the dose response of Kodak EDR2 film
    Childress, NL
    Rosen, II
    MEDICAL PHYSICS, 2004, 31 (08) : 2284 - 2288