Intensity modulated radiotherapy dosimetry with ion chambers, TLD, MOSFET and EDR2 film

被引:0
|
作者
R. A. Kinhikar
R. Upreti
S. Sharma
C. M. Tambe
D. D. Deshpande
机构
[1] Tata Memorial Hospital,Department of Medical Physics
关键词
IMRT; Ion chambers; TLD; MOSFET; EDR2 film;
D O I
暂无
中图分类号
学科分类号
摘要
Purpose of this study was to report in a together our experience of using ion chambers, TLD, MOSFET and EDR2 film for dosimetric verification of IMRT plans delivered with dynamic multileaf collimator (DMLC). Two ion chambers (0.6 and 0.13 CC) were used. All measurements were performed with a 6MV photon beam on a Varian Clinac 6EX LINAC equipped with a Millennium MLC. All measurements were additionally carried out with (LiF:Mg,TI) TLD chips. Five MOSFET detectors were also irradiated. EDR2 films were used to measure coronal planar dose for 10 patients. Measurements were carried out simultaneously for cumulative fields at central axis and at off-axis at isocenter plane (±1, and ±2cm). The mean percentage variation between measured cumulative central axis dose with 0.6 cc ion chamber and calculated dose with TPS was −1.4% (SD 3.2). The mean percentage variation between measured cumulative absolute central axis dose with 0.13 cc ion chamber and calculated dose with TPS was −0.6% (SD 1.9). The mean percentage variation between measured central axis dose with TLD and calculated dose with TPS was −1.8% (SD 2.9). A variation of less than 5% was found between measured off-axis doses with TLD and calculated dose with TPS. For all the cases, MOSFET agreed within ±5%. A good agreement was found between measured and calculated isodoses. Both ion chambers (0.6 CC and 0.13 CC) were found in good agreement with calculated dose with TPS.
引用
收藏
页码:25 / 32
页数:7
相关论文
共 50 条
  • [1] Intensity modulated radiotherapy dosimetry with ion chambers, TLD, MOSFET and EDR2 film
    Kinhikar, R. A.
    Upreti, R.
    Sharma, S.
    Tambe, C. M.
    Deshpande, D. D.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2007, 30 (01) : 25 - 32
  • [2] Compensator Based Intensity Modulated Radiation Therapy Dosimetry Using EDR2 Film
    Srivastava, R.
    De Wagter, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [3] The value of EDR2 film dosimetry in compensator-based intensity modulated radiation therapy
    Srivastava, R. P.
    DeWagter, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (19): : N449 - N457
  • [4] Kodak EDR2 film dosimetry: Effects of film orientation and phantom density
    Hsi, WC
    Chu, JCH
    Bernard, D
    MEDICAL PHYSICS, 2003, 30 (06) : 1478 - 1478
  • [5] Comprehensive evaluation of Kodak's EDR2 film for depth dose dosimetry
    Dogan, N
    Leybovich, LB
    Sethi, A
    MEDICAL PHYSICS, 2002, 29 (06) : 1367 - 1367
  • [6] Accuracy of Kodak's EDR2 film in measuring clinical dosimetry data
    Bieda, M
    Sarkar, A
    Das, I
    MEDICAL PHYSICS, 2002, 29 (06) : 1264 - 1264
  • [7] Experimental dosimetry of EDR2 films in scanning carbon-ion irradiation
    Wang, Weiwei
    Deng, Yu
    Huang, Zhijie
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (07):
  • [8] Accurately extracting dosimetry information from EDR2 film exposed to electron beams
    Khan, I
    Oh, M
    Rajagopalan, B
    Podgorsak, M
    MEDICAL PHYSICS, 2004, 31 (06) : 1861 - 1861
  • [9] Analysis of variation in H&D curve creation for EDR2 film dosimetry
    Bayouth, J
    Zhou, S
    Morrill, S
    MEDICAL PHYSICS, 2003, 30 (06) : 1450 - 1450
  • [10] Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator
    Zhu, XR
    Jursinic, PA
    Grimm, DF
    Lopez, F
    Rownd, JJ
    Gillin, MT
    MEDICAL PHYSICS, 2002, 29 (08) : 1687 - 1692