Monte Carlo dosimetry of the 60Co sources of a new GZP3 HDR afterloading system

被引:0
|
作者
Junxiang Wu
Shengwei Kang
Pei Wang
Jie Li
Xianliang Wang
机构
[1] Sichuan Cancer Hospital and Institute,
[2] Sichuan Cancer Center,undefined
[3] School of Medicine,undefined
[4] University of Electronic Science and Technology of China,undefined
[5] Radiation Oncology Key Laboratory of Sichuan Province,undefined
来源
关键词
Brachytherapy; Co source; Monte Carlo; Geant4; EGSnrc; Dosimetry;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Monte Carlo dosimetry of the 60Co sources of a new GZP3 HDR afterloading system
    Wu, Junxiang
    Kang, Shengwei
    Wang, Pei
    Li, Jie
    Wang, Xianliang
    [J]. RADIATION ONCOLOGY, 2023, 18 (01)
  • [2] Monte Carlo dosimetry of 60Co HDR brachytherapy sources
    Papagiannis, P
    Angelopoulos, A
    Pantelis, E
    Sakelliou, L
    Karaiskos, P
    Shimizu, Y
    [J]. MEDICAL PHYSICS, 2003, 30 (04) : 712 - 721
  • [3] Radial dose functions of GZP6 intracavitary brachytherapy 60Co sources: treatment planning system versus Monte Carlo calculations
    Mesbahi, A.
    [J]. IRANIAN JOURNAL OF RADIATION RESEARCH, 2008, 5 (04): : 181 - 186
  • [4] Comment on "Monte Carlo dosimetry of 60Co HDR brachytherapy sources" [Med. Phys. 30, 712-721 (2003)]
    Selvam, T. Palani
    Sahoo, Sridhar
    Vishwakarma, R. S.
    [J]. MEDICAL PHYSICS, 2010, 37 (09) : 5146 - 5147
  • [5] Monte Carlo Dosimetric Study of the GZP 60Co Brachytherapy Source with Stainless Steel Applicator
    Wu, J.
    Wang, P.
    Wang, X.
    Kang, S.
    Li, J.
    Tang, B.
    Orlandini, L. C.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E564 - E564
  • [6] Monte Carlo derivation of AAPM TG-43 dosimetric parameters for GZP6 Co-60 HDR sources
    Tabrizi, Sanaz Hariri
    Asl, Alireza Kamali
    Azma, Zohreh
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (02): : 153 - 160
  • [7] Monte Carlo study of a 60Co calibration field of the Dosimetry Laboratory Seibersdorf
    Hranitzky, C.
    Stadtmann, H.
    [J]. RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 153 - 156
  • [8] Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy
    Campos, Luciana Tourinho
    Veloso de Almeida, Carlos Eduardo
    [J]. PLOS ONE, 2015, 10 (09):
  • [9] EGSnrc Monte Carlo-aided dosimetric studies of the new BEBIG 60Co HDR brachytherapy source
    Anwarul, Islam Mohammad
    Akramuzzaman, Mir Md
    Abu Zakaria, Golam
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2013, 5 (03) : 148 - 156
  • [10] Monte Carlo Dosimetry of the 60Co Bebig High Dose Rate Source for Brachytherapy
    Campos, L. T.
    de Almeida, C. E. V.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3464 - 3464