Production of 95mTc for Compton camera imaging

被引:0
|
作者
Yuichi Hatsukawa
Kazuyuki Hashimoto
Kazuaki Tsukada
Tetsuya Sato
Masato Asai
Atsushi Toyoshima
Yasuki Nagai
Toru Tanimori
Shinya Sonoda
Shigeto Kabuki
Hideo Saji
Hiroyuki Kimura
机构
[1] Japan Atomic Energy Agency,Department of Physics
[2] Kyoto University,School of Medicine
[3] Tokai University,Faculty of Pharmaceutical Sciences
[4] Kyoto University,undefined
关键词
Technetium-95m; Compton camera imaging; MDP labeling; Mo(p,n); Tc reaction;
D O I
暂无
中图分类号
学科分类号
摘要
With the development of the Compton camera which can realize high position resolution, technetium isotopes emitting high energy gamma-rays are required. In this study, Technetium-95m which emits some gamma rays with higher than 200 keV was produced by the 95Mo(p,n)95mTc reaction. Image of gamma-rays from 95mTc was taken by a Compton gamma-ray camera.
引用
收藏
页码:1283 / 1285
页数:2
相关论文
共 50 条
  • [21] Separation of carrier free 95mTc from niobium targets irradiated with alpha-particles
    Sekine, T
    Konishi, M
    Kudo, H
    Tagami, K
    Uchida, S
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1999, 239 (03) : 483 - 487
  • [22] Prospectus: Development of a Compton camera for medical imaging
    Harkness, L. J.
    Boston, A. J.
    Boston, H. C.
    Cresswell, J. R.
    Grint, A. N.
    Lazarus, I.
    Judson, D. S.
    Nolan, P. J.
    Oxley, D. C.
    Scraggs, D. P.
    Simpson, J.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 102 - 105
  • [23] Effect of humic acid on the sorption of technetium on hematite colloids using 95mTc and 96Tc as tracers
    S. Kumar
    N. Rawat
    B. S. Tomar
    V. K. Manchanda
    S. Ramanathan
    Journal of Radioanalytical and Nuclear Chemistry, 2007, 274 : 229 - 231
  • [24] Effect of humic acid on the sorption of technetium on hematite colloids using 95mTc and 96Tc as tracers
    Kumar, S.
    Rawat, N.
    Tomar, B. S.
    Manchanda, V. K.
    Ramanathan, S.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 274 (02) : 229 - 231
  • [25] Imaging of 99mTc-DMSA and 18F-FDG in humans using a Si/CdTe Compton camera
    Nakano, Takashi
    Sakai, Makoto
    Torikai, Kota
    Suzuki, Yoshiyuki
    Takeda, Shin'ichiro
    Noda, Shin-ei
    Yamaguchi, Mitsutaka
    Nagao, Yuto
    Kikuchi, Mikiko
    Odaka, Hirokazu
    Kamiya, Tomihiro
    Kawachi, Naoki
    Watanabe, Shin
    Arakawa, Kazuo
    Takahashi, Tadayuki
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (05):
  • [26] Effect of detector parameters on the image quality of Compton camera for 99mTc
    An, S. H.
    Seo, H.
    Lee, J. H.
    Lee, C. S.
    Lee, J. S.
    Kim, C. H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2): : 251 - 254
  • [27] INFILTRATION OF RADIONUCLIDES WITH HIGH-MOBILITY (BR-82 AND 95MTC) INTO A FOREST SOIL - EFFECT OF THE IRRIGATION INTENSITY
    SCHIMMACK, W
    BUNZL, K
    KLOTZ, D
    SCIENCE OF THE TOTAL ENVIRONMENT, 1993, 138 (1-3) : 169 - 181
  • [28] Bin mode estimation methods for Compton camera imaging
    Ikeda, S.
    Odaka, H.
    Uemura, M.
    Takahashi, T.
    Watanabe, S.
    Takeda, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 760 : 46 - 56
  • [29] Experimental studies with a Compton camera for phantom and patient imaging
    Llosa, G.
    Barrientos, L.
    Calatayud, J.
    Casana, J.
    Bello, P.
    Prado, S.
    Roser, J.
    Senra, C.
    Torres-Espallardo, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S342 - S342
  • [30] Compton camera imaging and the cone transform: a brief overview
    Terzioglu, Fatma
    Kuchment, Peter
    Kunyansky, Leonid
    INVERSE PROBLEMS, 2018, 34 (05)